Mohsen Barzegar

Dr. Mohsen Barzegar

orcid
Instituto de Telecomunicações

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2025 in Mechanical Systems and Signal Processing
Verified
Journal Article
Open access
Mohsen BarzegarMohsen Barzegar
Mohsen Barzegar
SCSahar Moradi Cherati
Sahar Moradi Cherati
DPDario J. Pasadas
Dario J. Pasadas
CPChiara Pernechele
Chiara Pernechele
ARArtur L. Ribeiro
Artur L. Ribeiro
HRHelena G. Ramos
Helena G. Ramos

17 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Mohsen BarzegarMohsen Barzegar
Mohsen Barzegar
DPDario Pasadas
Dario Pasadas
ARArtur Ribeiro
Artur Ribeiro
HRHelena Ramos
Helena Ramos
YLYevgeniya Lugovtsova
Yevgeniya Lugovtsova
JBJannis Bulling
Jannis Bulling
Wavefield measurements by a scanning laser Doppler vibrometer are generally carried out in a cartesian coordinate. As a piezoelectric transducer generates Lamb waves following radial paths, the use of a polar coordinate can be a suitable alternative to the use of a cartesian coordinate. Therefore, in the proposed method, using a single transducer placed on the center of the specimen, the measured wavefields are transformed into polar coordinates, making several identical radial line inspections from the center in a direction of incident waves. Taking advantage of the properties of the polar coordinates, a signal processing technique is proposed through a frequency-wavenumber filtering process in these coordinates. In this technique, by using proper filters, unwanted wave modes of the incident wave along with all reflected waves are filtered out. In addition, the conventional features of RMS and Euclidean distance are adapted for the polar coordinate system to image the bonded plate. The proposed signal processing and damage imaging are first introduced through a numerical simulation. Then, the performance of the proposed technique is presented by experimental measurements of two specimens including adhesively bonded carbon fiber-reinforced plastic composite plates and bonded aluminum plates.

22 February 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Mohsen BarzegarMohsen Barzegar
Mohsen Barzegar
DPDario Pasadas
Dario Pasadas
ARArtur Ribeiro
Artur Ribeiro
HRHelena Ramos
Helena Ramos
This paper compares low-frequency Lamb waves in a pitch-catch configuration and high-frequency bulk waves in a pulse-echo mode for ultrasonic C-scan imaging of composite lap joints. The pulse-echo measurement is conducted by using a delay line transducer. On the other hand, the ultrasonic guided waves are measured in a pitch-catch configuration by using a PZT disk moved by a positioning system over the scan area. In both methods, the signals are acquired in a C-scan manner over the adhesive joint area. Applying signal processing techniques, including frequency-wavenumber filtering, and bandpass filtering, along with different feature extraction, images of the scan area are obtained. For this study, two different types of composite lap joints are used. The first joint consists of composite plates reinforced with woven composite fabric, with defects in the form of missing adhesive. In the second joint, quasi-isotropic composite plates are employed, and disbonds are used to simulate defects. The Fisher discriminant criterion is used to assess the capability of each method in accurately distinguishing defects from the pristine condition. The paper concludes with a discussion of the results and effects of using both techniques.

28 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DPDario Pasadas
Dario Pasadas
Mohsen BarzegarMohsen Barzegar
Mohsen Barzegar
ARArtur Ribeiro
Artur Ribeiro
HRHelena Ramos
Helena Ramos
In this paper, guided Lamb wave tomography and eddy current testing (ECT) techniques were combined to locate and evaluate fiber breaks in carbon-fiber-reinforced plastic (CFRP) structures. Guided wave testing (GWT) and computed tomography (CT) imaging were employed to quickly locate fiber breaks in the CFRP plate. From B-scans performed along two different fiber orientations (0 and 90 degrees), parallel-beam projections of different features were extracted from the guided wave signals, using signal-processing techniques (such as wavelet and Hilbert transforms) and statistical functions (such as skewness and kurtosis). The parallel-beam projections of each individual feature were used as input in computed tomography imaging reconstruction to approximately estimate the location of fiber breaks. From the obtained reconstructed images, image-fusion techniques were applied to get complementary information from multiple source images into one single image. After locating the fiber breaks, C-scans were performed in the vicinity of the damage, using an ECT probe with double excitation configuration to evaluate the condition of the fiber break.

7 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DPDario Pasadas
Dario Pasadas
Mohsen BarzegarMohsen Barzegar
Mohsen Barzegar
ARArtur Ribeiro
Artur Ribeiro
HRHelena Ramos
Helena Ramos
In this paper, non-destructive testing using ultrasonic Lamb waves with a movable contact piezoelectric transducer (PZT) receiver is introduced for crack depth evaluation and damage imaging. An angle beam transducer (ABT) was used to excite a predominant S0 mode in an aluminum plate containing cracks with different depths, and a movable PZT disk was used to measure the wavefield in the plate. From the wavefield data collected by the measurement system, transmitted and reflected waves caused by the presence of cracks were analyzed in the space-time and frequency-wavenumber domains. Frequency-wavenumber filters were employed to separate the incident and transmitted waves from reflected waves. The root mean square (RMS) of recorded signals was computed as a feature to provide information about the damage characteristics. The frequency and wavenumber variations of each mode were analyzed before and after the crack position to evaluate different crack depths. The filtered data obtained in the frequency-wavenumber domain was transformed back to the space-time domain using the inverse 2D FFT, and an image fusion of reflected and transmitted RMS maps was implemented for damage imaging. This investigation has demonstrated the potential of using movable PZT sensors for collecting wavefield measurements for damage detection, visualization, and characterization.

29 February 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Mohsen BarzegarMohsen Barzegar
Mohsen Barzegar
YLYevgeniya Lugovtsova
Yevgeniya Lugovtsova
JBJannis Bulling
Jannis Bulling
TMTatiana Mishurova
Tatiana Mishurova
DPDario Pasadas
Dario Pasadas
HRHelena Ramos
Helena Ramos
Adhesively bonded composite joints can develop voids and porosity during fabrication, leading to stress concentration and a reduced load-carrying capacity. Hence, adhesive porosity analysis during the fabrication is crucial to ensure the required quality and reliability. Ultrasonic guided wave-based techniques without advanced signal processing often provide low-resolution imaging and can be ineffective for detecting small-size defects. This paper proposes a damage imaging process for adhesive porosity analysis of bonded composite plates using ultrasonic guided waves measured by scanning laser Doppler vibrometer. To implement this approach, a piezoelectric transducer is mounted on the composite joint specimen to generate ultrasonic guided waves, which are measured over a densely sampled area. The signals obtained from the scan are processed using the proposed signal processing in different domains. Through the utilization of filter banks in frequency and wavenumber domains, along with the root-mean-square calculation of filtered signals, damage images of the adhesive region are obtained. It has been observed that different filters provide information related to different void sizes. Combining all the images reconstructed by filters, a final image is obtained which contains damages of various sizes. The images obtained by the proposed method are verified by radiography results and the porosity analysis is presented. The results indicate that the proposed methodology can detect the pores with the smallest detectable pore area of 2.41 mm², corresponding to a radius of 0.88 mm, with an overall tendency to overestimate the pore size by an average of 11 percent.