Morteza Maleki

Dr. Morteza Maleki

Department of Electrical & Information Engineering, Politecnico di Bari, Bari, Puglia, Italy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2020 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
Morteza MalekiMorteza Maleki
Morteza Maleki
MMMahdiyeh Mehran
Mahdiyeh Mehran
AAARASH Mokhtari Ardekani
ARASH Mokhtari Ardekani
In this work, a gas sensor based on the plasmonic double-layer graphene nanograting (GNG) structure with an enhanced figure of merit (FoM) is presented in the near-infrared region. This structure includes double periodic graphene nanoribbon arrays, separated by a dielectric. The wavelength interrogation method is employed to accurately investigate the behavior of the proposed structure for various physical and geometrical parameters, including the array pitch, graphene nanoribbon width, refractive index of the intermediate dielectric between the GNGs, and the chemical potential of the graphene. A sharp dip is achieved by the guided-mode resonance between the two GNG layers, due to their near-field coupling. For the optimized design, obtained sensitivity and FoM are 430.91 nm/RIU and 174.68 R I U − 1 , respectively, when the finite-element method is used for the simulations. The high FoM is a result of the field enhancement at the edges of the graphene nanoribbons, as well as the narrow resonance linewidth achieved by the sharp transmission dip. In addition to the high performance and FoM, the structure is robust to the misalignment of two GNG layers, offering a solution for practical gas sensing applications. To the best of our knowledge, the proposed GNG-based structure enjoys a boosted FoM compared to the previously proposed integrated gas sensors, as well as a practically feasible design for fabrication.

24 May 2022 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
Morteza MalekiMorteza Maleki
Morteza Maleki
MMMahdiyeh Mehran
Mahdiyeh Mehran
This work performs a quantitative comparison of different dielectric-based guided-mode resonance (D-GMR) sensors. To this end, diverse D-GMR structures are classified into three different classes, and their sensitivity (S) is compared to each other. For one of these classes in various schemes, the sensitivity is investigated for the TE and TM modes. Moreover, grating height effects are studied for different cases in this category, and analytical sensitivity equations are used as benchmarks. Then, the three classes are compared and, based on the numerical results and analytical equations, various applications are proposed for different structures in the refractive index (RI) of interest. Comparing our results to other recent works, we prove that the proposed classification leads to great sensing performances and the predictions are reliable. A comparison has been performed for methane as a gas sample (with RI of 1.0003) and a hemoglobin solution and toluene as two different analytes (with RIs of 1.33 and 1.4778, respectively). The results show a sensitivity of S = 1427.3 n m / r e f r a c t i v e index unit (nm/RIU) for methane with a detection precision of one to a few volume percentages in the air, which can also be calibrated to illuminate the fabrication variation errors. For hemoglobin, a sensitivity of 1073.4 nm/RIU is obtained, with a limit of detection of 116.15 mg/lit for 65-87 g/lit of hemoglobin in water; for the toluene sensor, S = 1019.7 n m / R I U is calculated. As a general result, a high figure of merit/sensitivity can be achieved over a wide range of applications, from gases to high RI analytes, using our proposed classifications.

26 July 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FMFatemeh Fouladi Mahani
Fatemeh Fouladi Mahani
Morteza MalekiMorteza Maleki
Morteza Maleki
AAARASH Mokhtari Ardekani
ARASH Mokhtari Ardekani
PBPierre Berini
Pierre Berini
A novel and efficient Fabry-Perot biosensor on the tip of a dual-core single-mode optical fiber is proposed. The incident light emerges from one of the cores and is coupled to the second core via high-contrast silicon nitride slanted grating couplers (SGCs), separated by a silicon nitride waveguide segment disposed along the fiber tip. The challenges in designing high-contrast SGCs of very short length were overcome using an efficient analytical design approach augmented by simulations in 2D, resulting in grating designs that produce core-to-core coupling efficiencies of up to 29%. The waveguide segment separating the SGCs acts as a Fabry-Perot sensing cavity producing narrow Fabry-Perot fringes in the transmittance spectrum of the structure. Monitoring these fringes leads to bulk sensitivity and figure of merit of 50 - 100 nm/RIU and 16.67 - 33.34 (RIU-1), for sensing a large range of biomaterials. The structure operates in transmission, thus eliminating the need to separate the reflected light from the incident light at the input of the fiber, which simplifies the interrogation system. Properly packaged, the fiber tip can be dipped or inserted directly into the sensing medium, which removes the need for microfluidics. The scheme enables robust, flexible, compact, and remotely-interrogated biosensors.

6 June 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Morteza MalekiMorteza Maleki
Morteza Maleki
MMMahdiyeh Mehran
Mahdiyeh Mehran
The high quality factor of guided mode resonance (GMR) structures and their sensitivity to the adjacent media’s refractive index (RI) make them excellent candidates for sensing applications. In this study, we derive analytical sensitivity equations for the GMR structures for the first time, which can be utilized to better understand and optimize their behavior. The simulated structures (based on the finite element method) show excellent agreement with the analytical sensitivities for both the transverse electric and magnetic (TE and TM) modes. The effects of waveguide height, working wavelength, and material RIs on the obtained sensitivities were surveyed, which helped achieve a design approach based on the analytical equations. The substrate RI should be as low as possible for any application. For analytes, the RI of the waveguide thin film should be low, whereas this trend is different for gas sensors; there is an optimum RI for the waveguide in the TE mode, and in the TM mode, the waveguide should have a higher possible RI. Moreover, the TM-mode gas sensors exhibit optimum sensitivity for a specified waveguide height. The design approach was used for a gas sensor operating at methane resonance wavelength (1653.7 nm), which can be tuned using a double-layer graphene sheet. A linear tunability of up to 5 nm was achieved using 1 eV chemical potential adjustment, whereas the device sensitivity remains between 291.9 to 295.5 nm/RIU. Moreover, higher sensitivities up to 950 nm/RIU can be obtained for analyte sensors at 1550 nm.

10 February 2024 in Optik
Verified
Journal Article
Closed access
AMAsghar Moradi
Asghar Moradi
Morteza MalekiMorteza Maleki
Morteza Maleki
SHSeyyed Reza Hosseini
Seyyed Reza Hosseini
MBMahsa Bahramgour
Mahsa Bahramgour
NDNagihan Delibas
Nagihan Delibas
ANAligholi Niaei
Aligholi Niaei

29 October 2024 in Plasmonics
Verified
Journal Article
Closed access
PDF file
PKParisa Khajegi
Parisa Khajegi
MHMajid Rashidi Huyeh
Majid Rashidi Huyeh
BPBruno Palpant
Bruno Palpant
Morteza MalekiMorteza Maleki
Morteza Maleki