To reduce the Carbon footprint and reduce emissions from the globe, the world has kicked-off to leave reliance of fossil fuels and generate electrical energy from renewable energy sources. The MOOPF problem is becoming more complex, and the number of decision variables is increasing, with the introduction of power electronics-based Flexible AC Transmission Systems (FACTS) devices. These power system components can all be used to increase controllability, effectiveness, stability, and sustainability. The added uncertainty and variability that FACTS devices and wind generation provide to the power system makes it challenging to find the right solution to MOOPF issues. In order to determine the best combination of control and state variables for the MOOPF problem, this paper develops three cases of competing objective functions. These cases include minimizing the total cost of power produced as well as over- and underestimating the cost of wind generation, emission rate, and the cost of power loss caused by transmission lines. In the case studies, power system optimization is done while dealing with both fixed and variable load scenarios. The proposed algorithm was tested on three different cases with different objective functions. The algorithm achieved an expected cost of $833.014/h and an emission rate of conventional thermal generators of 0.665 t/h in the case 1. In Case 2, the algorithm obtained a minimum cost of $731.419/h for active power generation and a cost of power loss is 124.498 $/h for energy loss. In Case 3, three objective functions were minimized simultaneously, leading to costs of $806.6/h for emissions, 0.647 t/h, and $214.9/h for power loss.
Electricity theft (ET), which endangers public safety, creates a problem with the regular operation of grid infrastructure and increases revenue losses. Numerous machine learning, deep learning, and mathematical-based algorithms are available to find ET. Still, these models do not produce the best results due to problems like the dimensionality curse, class imbalance, improper hyper-parameter tuning of machine learning and deep learning models, etc. We present a hybrid deep learning model for effectively detecting electricity thieves in smart grids while considering the abovementioned concerns. Pre-processing techniques are first employed to clean up the data from the smart meters. Then, the feature extraction technique, like AlexNet, addresses the curse of dimensionality. The effectiveness of the proposed method is evaluated through simulations using a real dataset of Chinese intelligent meters. To conduct a comparative analysis, various benchmark models are implemented as well. Our proposed model achieves accuracy, precision, recall, and F1, up to 86%, 89%, 86%, and 84%, respectively.
Due to global warming, governments around the world are focusing on renewable energy as the main source of energy. Gulf countries in particular, are focusing on solar energy due to its abundance and the gulf geolocation that allows the installation of ambitious solar photovoltaic (PV) energy systems and replace conventional power plants. In order to maximize energy extraction from the sun, solar power operators need to constantly monitor key solar PV parameters such as panel temperature, solar irradiation, voltage and current in order to detect abnormalities in the PV system operation and take the necessary actions to keep the PV system performance at its maximum. However, monitoring such parameters on-site is exhausting and expensive. Moreover, remote monitoring for solar PV systems is a more attractive solution once the data collection, processing and transmission become faster and less expensive. This paper describes the design of a low-cost remote monitoring system intended for off-grid solar PV systems. The designed remote monitoring system uses a combination of an Arduino Uno Wi-Fi demilitarized zone (DMZ) communication system with router-configured network sensors calibrated to fulfill the IEC-61,724 standards and it provides meteorological and electrical measurements with an error of 2% or less. There are four primary features of the proposed monitoring system. First, it combines the Arduino Uno Wi-Fi with a DMZ configuration in the router. Second, it complies with the minimum current, voltage, power, and PV-module temperature values set by the IEC-61,724 in such a way that the average error does not exceed the 4% threshold. Third, it provides an accuracy level of 98% for the meteorological and electrical parameters. This level of accuracy exceeds that of commercial data logging equipment. Finally, its total cost is less than $100, which is less than that of available commercial solar PV monitoring systems. Additional features include the ability to select the number of processed measurements per hour and innovative processing, display, and access schemes. These features enable the accessibility of the data from mobile phones and computers within the campus for teaching and experimentation purposes.
Fog-radio access networks (F-RANs) alleviate fronthaul delays for cellular networks as compared to their cloud counterparts. This allows them to be suitable solutions for networks that demand low propagation delays. Namely, they are suitable for millimeter wave (mmWave) operations that suffer from short propagation distances and possess a poor scattering environment (low channel ranks). The F-RAN here is comprised of fog nodes that are collocated with radio remote heads (RRHs) to provide local processing capabilities for mobile station (MS) terminals. These terminals demand various network functions (NFs) that correspond to different service requests. Now, provisioning these NFs on the fog nodes also yields service delays due to the requirement for service migration from the cloud, i.e., offloading to the fog nodes. One solution to reduce this service delay is to provide cached copies of popular NFs in advance. Hence, it is critical to study function popularity and allow for content caching at the F-RAN. This is further a necessity given the limited resources at the fog nodes, thus requiring efficient resource management to enhance network capacity at reduced power and cost penalty. This paper proposes novel solutions that allocate popular NFs on the fog nodes to accelerate services for the terminals, namely, the clustered and distributed caching methods. The two methods are analyzed and compared against the baseline uncached provisioning schemes in terms of service delay, energy consumption, and cost.
The growing popularity of electric vehicles presents a significant challenge to current electric grids since the rising number of these vehicles places additional strain on power systems inside distribution networks. A proposed paradigm is presented for electric vehicles (EVs), which is subsequently partitioned into three distinct dispatching areas to assess its practicality. This study is structured around two primary objectives. The first objective focuses on EV owners aiming to minimize their electricity consumption costs while also receiving compensation for providing services. The second objective involves using an aggregator to establish distinct tariffs for each dispatching area. Additionally, the aggregator aims to shift the charging load demand from peak to off-peak hours and distribute the charging demand to each agent. The authors of this study propose the utilization of a charging and discharging coordination method, specifically the Multi-Agents Charging and Discharging (MACD) algorithm, as a means to successfully tackle the issue of charging demand during peak hours. The objective of the proposed algorithm is to effectively handle the increased charging requirements during peak periods by using vehicle-to-grid (V2G) technologies within the context of Smart Grid systems and electric vehicle (EV) batteries. Importantly, this reduction is achieved without compromising the performance of electric vehicles (EVs) or the convenience experienced by EV owners. The algorithm under consideration demonstrates reduced power charging costs for various sectors. Specifically, it achieves a decrease of 15% for households, 14.6% for corporate buildings, and 14.5% for Industrial Park EV aggregators.
This paper evaluates the performance of the 9.8 kW grid-connected solar photovoltaic (PV) system mounted on the rooftop of the College of Engineering within the King Faisal University campus. The facility consists of four fields rated 2.45 kW each. Each field consists of ten 10 solar panels connected to a 3kW. The collected data include hourly and sub-hourly measurements of the radiation, ambient and module temperatures, AC and DC voltages, currents, and power outputs. Other measurements include cumulative produced energy and CO2 savings. The assessed parameters of the PV facility include daily, and monthly energy, final yield, efficiency, and module performance ratio (PR). Aggregate performance analysis results show that the station operated as planned. The annual radiation measured in 2017 reached 2449 kWh/m2 with a daily average of 6.710 kWh/m2. The annual energy production reached 16.047 MWh with an average of 43.964 kWh/day. The system efficiency and capacity factor are 11.22% and 17.25%, respectively.