Muhammed Worku

Dr. Muhammed Worku

King Fahd University of Petroleum and Minerals
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MWMuhammed Worku
Muhammed Worku
The reduction of greenhouse gas emissions and strengthening the security of electric energy have gained enormous momentum recently. Integrating intermittent renewable energy sources (RESs) such as PV and wind into the existing grid has increased significantly in the last decade. However, this integration hampers the reliable and stable operation of the grid by posing many operational and control challenges. Generation uncertainty, voltage and angular stability, power quality issues, reactive power support and fault ride-through capability are some of the various challenges. The power generated from RESs fluctuates due to unpredictable weather conditions such as wind speed and sunshine. Energy storage systems (ESSs) play a vital role in mitigating the fluctuation by storing the excess generated power and then making it accessible on demand. This paper presents a review of energy storage systems covering several aspects including their main applications for grid integration, the type of storage technology and the power converters used to operate some of the energy storage technologies. This comprehensive review of energy storage systems will guide power utilities; the researchers select the best and the most recent energy storage device based on their effectiveness and economic feasibility.

17 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
MWMuhammed Worku
Muhammed Worku
MHMohamed A. Hassan
Mohamed A. Hassan
Luqman MaraabaLuqman Maraaba
Luqman Maraaba
Md ShafiullahMd Shafiullah
Md Shafiullah
MEMOHAMED RAGAB MUSTAFA ELKADEEM
MOHAMED RAGAB MUSTAFA ELKADEEM
Mohamed AbidoMohamed Abido
Mohamed Abido
To operate photovoltaic (PV) systems efficiently, the maximum available power should always be extracted. However, due to rapidly varying environmental conditions such as irradiation, temperature, and shading, determining the maximum available power is a time-varying problem. To extract the maximum available power and track the optimal power point under these varying environmental conditions, maximum power point tracking (MPPT) techniques are proposed. The application of MPPT for extracting maximum power plays a crucial role in developing efficient PV systems. These MPPT techniques face several issues and limitations, particularly during partial shading conditions caused by non-uniform environmental conditions. Researchers have been focusing more on mitigating the partial shading condition in PV systems for the last few years due to the need to improve power output and efficiency. This paper provides an overview of MPPTs proposed in the literature for uniform and non-uniform environmental conditions broadly categorized as MPPT-based and circuit-based methods. The MPPT-based methods are classified as conventional, soft computing, and hybrid techniques. A critical analysis of each approach regarding tracking speed, algorithm complexity, and dynamic tracking under partial shading is discussed. The literature shows hybrid strategies provide fast-tracking speed and are efficient with a tracking efficiency of around 99% compared to conventional methods; however, their design and practical implementation are complex. This comprehensive review of MPPT methods aims to provide power utilities and researchers with a reference and guideline to select the best MPPT method for normal operation and partially shaded PV systems based on their effectiveness and economic feasibility.

30 January 2024 in IEEE Access
Verified
Journal Article
Open access
MZMuiz M. Zaben
Muiz M. Zaben
MWMuhammed Worku
Muhammed Worku
MHMohamed A. Hassan
Mohamed A. Hassan
Mohamed AbidoMohamed Abido
Mohamed Abido
AC microgrids are becoming increasingly important for providing reliable and sustainable power to communities. However, the evolution of distribution systems into microgrids has changed the way they respond to faults and hence their protection requirements. Faults in microgrids could hinder operation stability and damage the system components. The types, locations, and resistances of faults, as well as microgrid operation modes, distributed generation penetration levels, load changes, and system topologies, all affect how the microgrid responds to faults. In order to offer quick restoration and to protect the microgrid components, fault detection and classification are therefore essential for microgrids. In this direction, unconventional methods such as artificial intelligence have been increasing in popularity over the last years. Pattern recognition is a methodology that machine learning as an approach to artificial intelligence is concerned with. The combination of protection with machine learning may be motivating in order to achieve the goal of intelligent operation in the smart grid. In this paper, fault detection, classification and location methods are reviewed for microgrid application. Different methods applied for both fault location and fault classification are being classified by the implemented technique. Such methods are explained and analyzed providing the main advantages and disadvantages of each category. Additionally, the research trends in both fields are analyzed and state–of–the–art methods from each category are thoroughly compared. Finally, the research gaps and future directions are identified.

16 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
MWMuhammed Worku
Muhammed Worku
MHMohamed A. Hassan
Mohamed A. Hassan
Mohamed AbidoMohamed Abido
Mohamed Abido
An efficient power management control for microgrids with energy storage is presented in this paper. The proposed control scheme increases the reliability and resiliency of the microgrid based on three distributed energy resources (DERs), namely Photovoltaic (PV), battery, and diesel generator with local active loads. Coordination among the DERs with energy storage is essential for microgrid management. The system model and the control strategy were developed in Real Time Digital Simulator (RTDS). Decoupled d-q current control strategy is proposed and implemented for voltage source converters (VSCs) used to interface the PV and battery sources to the AC grid. A dc-dc buck converter with a maximum power point tracking function is implemented to maximize the intermittent energy generation from the PV array. A controller is proposed and employed for both grid connected and island modes of operation. In grid connected mode, the system frequency and voltage are regulated by the grid. During a fault in island mode, the diesel generator controls the system frequency and voltage in isochronous mode. Results based on the real time digital simulator are provided to verify the superiority and effectiveness of the proposed control scheme.

9 December 2021 in Mathematics
Verified
Journal Article
Open access
PDF file
MWMuhammed Worku
Muhammed Worku
MHMohamed A. Hassan
Mohamed A. Hassan
Luqman MaraabaLuqman Maraaba
Luqman Maraaba
Mohamed AbidoMohamed Abido
Mohamed Abido
Microgrids that are integrated with distributed energy resources (DERs) provide many benefits, including high power quality, energy efficiency and low carbon emissions, to the power grid. Microgrids are operated either in grid-connected or island modes running on different strategies. However, one of the major technical issues in a microgrid is unintentional islanding, where failure to trip the microgrid may lead to serious consequences in terms of protection, security, voltage and frequency stability, and safety. Therefore, fast and efficient islanding detection is necessary for reliable microgrid operations. This paper provides an overview of microgrid islanding detection methods, which are classified as local and remote. Various detection methods in each class are studied, and the advantages and disadvantages of each method are discussed based on performance evaluation indices such as non-detection zone (NDZ), detection time, error detection ratio, power quality and effectiveness in multiple inverter cases. Recent modifications on islanding methods using signal processing techniques and intelligent classifiers are also discussed. Modified passive methods with signal processing and intelligent classifiers are addressing the drawbacks of passive methods and are getting more attention in the recently published works. This comprehensive review of islanding methods will provide power utilities and researchers a reference and guideline to select the best islanding detection method based on their effectiveness and economic feasibility.

17 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
Luqman MaraabaLuqman Maraaba
Luqman Maraaba
KAKhaled Yousef Al-Soufi
Khaled Yousef Al-Soufi
TSTWAHA SSENNOGA
TWAHA SSENNOGA
AMAzhar Memon
Azhar Memon
MWMuhammed Worku
Muhammed Worku
LALuai M. Alhems
Luai M. Alhems
Insulators are considered one of the most significant parts of power systems which can affect the overall performance of high-voltage (HV) transmission lines and substations. High-voltage (HV) insulators are critical for the successful operation of HV overhead transmission lines, and a failure in any insulator due to contamination can lead to flashover voltage, which will cause a power outage. However, the electrical performance of HV insulators is highly environment sensitive. The main cause of these flashovers in the industrial, agricultural, desert, and coastal areas, is the insulator contamination caused by unfavorable climatic conditions such as dew, fog, or rain. Therefore, the purpose of this work is to review the different methods adopted to identify the contamination level on high-voltage insulators. Several methods have been developed to observe and measure the contamination level on HV insulators, such as leakage current, partial disgorgement, and images with the help of different techniques. Various techniques have been discussed alongside their advantages and disadvantages on the basis of the published research work in the last decade. The major high-voltage insulator contamination level classification techniques discussed include machine learning, fuzzy logic, neuro–fuzzy interface, detrended fluctuation analysis (DFA), and other methods. The contamination level data will aid the scheduling of the extensive and costly substation insulator, and live line washing performed using high-pressured water. As a result, considerable benefits in terms of improved power system reliability and maintenance cost savings will be realized. This paper provides an overview of the different signal processing and machine-learning methods adopted to identify the contamination level on high-voltage insulators. Various methods are studied, and the advantages and disadvantages of each method are discussed. The comprehensive review of the islanding methods will provide power utilities and researchers with a reference and guideline to select the best method to be used for contamination level identification based on their effectiveness and economic feasibility.