Mulusew Ayalew Yeshaneh

Mr. Mulusew Ayalew Yeshaneh

Instructor
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
MYMulusew Ayalew Yeshaneh
Mulusew Ayalew Yeshaneh
Baseem KhanBaseem Khan
Baseem Khan
IGIssaias Giday
Issaias Giday
Om Prakash MahelaOm Prakash Mahela
Om Prakash Mahela
Mahdi KhosravyMahdi Khosravy
Mahdi Khosravy
MYMulusew Ayalew Yeshaneh
Mulusew Ayalew Yeshaneh
Electrical energy is critical to a country’s socioeconomic progress. Distribution system expansion planning addresses the services that must be installed for the distribution networks to meet the expected load need, while also meeting different operational and technical limitations. The incorporation of distributed generation sources (DGs) alters the operating characteristics of modern power systems, resulting in major economic and technical benefits, such as simplified distribution network expansion planning, lower power losses, and improved voltage profile. Thus, in this study, an analytical method is used to design the expansion planning of the Addis North distribution network considering the integration of optimal sizes of distributed generations for the projected demand growths. To evaluate the capability of the existing Addis North distribution network and its capability to supply reliable power considering future expansion, the load demand forecast for the years 2020–2030 is done using the least square method. The performance evaluation of the existing and the upgraded network considering the existing and forecasted load demand for the years 2030 is done using ETAP software. Accordingly, the results revealed that the existing networks cannot meet the existing load demand of the town, with major problems of increased power loss and a reduced voltage profile. To mitigate this problem, the Addis North feeder-1 distribution network is upgraded and for each study case, the balanced and positive sequence load flow analysis was executed and the maximum total real and reactive power losses were found at bus 29. The result shows that the upgraded network of bus 29 was the optimal location of DG and its size was 9.93 MW. After the optimal size of DG was placed at this bus, the real and reactive power losses of the upgraded networks were 0.2939 MW and 0.219 MVAr, respectively. At bus 29 the maximum power losses reduction and voltage profile improvements were found. The active and reactive power losses were minimized by 21.285% and 19.633% respectively and the voltage profiles were improved by 8.78%. Thus, in the predicted year 2030, DG power sources could cover 61.12% of the feeder-1 power requirements.

29 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
MYMulusew Ayalew Yeshaneh
Mulusew Ayalew Yeshaneh
Baseem KhanBaseem Khan
Baseem Khan
ZAZuhair Muhammed Alaas
Zuhair Muhammed Alaas
In the event of a fault isolation process, all loads located downstream from the faulted point become out of service, and as a consequence, the power interruption affects a greater portion of the radial distribution system. This paper proposes an optimal Service Restoration (SR) method that entails changing the network topology configuration via optimal tie-switch and section switch combinations. However, when the network topology configuration is performed, it results in increased load currents. As a result, some Protective Devices (PDs) can operate undesirably and some network branches may become unprotected. Therefore, it is essential to consider protection constraints in the SR problem to maintain service continuity during power interruptions. The proposed method aims at optimal SR with minimum out-of-service loads, minimum power loss, and improved voltage profiles and at the same time ensures PDs operate correctly during the normal and overloading conditions. The proposed method was carried out on the Debre Markos distribution networks, using the Teaching Learning Based Optimization (TLBO), Particle Swarm Optimization (PSO), and Differential Evolutionary (DEV) algorithms. The proposed SR was carried out considering and without considering protection constraints. The obtained SR topology was not feasible for SR without considering protection constraints, since some PDs fail to operate properly in normal loading conditions. After executing the proposed SR algorithms by considering protection constraints for a single fault case, the power loss reductions in TLBO, DEV, and PSO were 64.9073%, 45.9073%, and 55.358 %, respectively. The minimum voltage profiles obtained in each proposed TLBO, DEV, and PSO algorithm were 0.96%, 0.95%, and 0.96%, respectively. In each algorithm, except for the branch under fault, all healthy out-of-service branches were restored. When the protection constraints were considered in an optimal SR, load current did not exceed the rating of the fuses. The results show the importance of considering protection constraints during SR to prevent dysfunction of the PDs in the network. Comparative analyses were carried out on each algorithm and TLBO algorithms performed better than PSO and DEV for search functions.