Narges Yousefpour

Ms. Narges Yousefpour

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Hadi Mokhtari DowlatabadHadi Mokhtari Dowlatabad
Hadi Mokhtari Dowlatabad
AMAmir Mamdouh
Amir Mamdouh
NYNarges Yousefpour
Narges Yousefpour
RMReihane Mahdavi
Reihane Mahdavi
AZAshkan Zandi
Ashkan Zandi
MAMohammad Abdolahad
Mohammad Abdolahad
A gigahertz (GHz) range antenna formed by a coaxial probe has been applied for sensing cancerous breast lesions in the scanning platform with the assistance of a suction tube. The sensor structure was a planar central layer and a metallic sheath of size of 3 cm2 connected to a network analyzer (keySight FieldFox N9918A) with operational bandwidth up to 26.5 GHz. Cancer tumor cells have significantly higher water content (as a dipolar molecule) than normal breast cells, changing their polarization responses and dielectric losses to incoming GHz-based stimulation. Principal component analysis named S11, related to the dispersion ratio of the input signal, is used as a parameter to identify malignant tumor cells in a mouse model (in vivo) and tumor specimens of breast cancer patients (in vitro) (both central and marginal parts). The results showed that S11 values in the frequency range from 5 to 6 GHz were significantly higher in cancer-involved breast lesions. Histopathological analysis was the gold standard for achieving the S11 calibration to distinguish normal from cancerous lesions. Our calibration on tumor specimens presented 82% positive predictive value (PPV), 100% negative predictive value (NPV), and 86% accuracy. Our goal is to apply this system as an in vivo non-invasive tumor margin scanner after further investigations in the future.

25 November 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
JFJalil Beheshti Firoozabadi
Jalil Beheshti Firoozabadi
RMReihane Mahdavi
Reihane Mahdavi
KSKhosro Shamsi
Khosro Shamsi
HAHossein Ataee
Hossein Ataee
ASAbdollah Shafiee
Abdollah Shafiee
MAMohammad Abdolahad
Mohammad Abdolahad
Precise diagnosis of thyroid nodules is challenging due to non-diagnostic/inconclusive results and uncertainties about the malignancy of follicular neoplasms (FNs), even in frozen-section pathology. Therefore, surgical management, especially in Bethesda III and IV categories, may be complicated, and sometimes a second surgery may be required. The Thyroid Nodule Impedance Measurement System (TN-IMS) consists of a metallic patch attached to submental skin and a G20 I.V. cannula inserted into the targeted nodules. Two impedance-based parameters named Z1kHz and impedance phase slope (IPS) in 100 kHz to 500 kHz of the thyroid nodules are recorded and compared with their histopathological results as the gold standard. TN-IMS was intra-surgically applied to 103 human thyroid nodules and normal thyroid tissues. A remarkable consistency between defined co-ranges of Z1kHz/IPS and the histopathological status of specimens was achieved (p < 0.001). Based on these measurements, it was concluded that intraoperative bioelectrical impedance scanning of thyroid nodules would be a helpful complementary approach to detecting high-risk excision-required thyroid nodules.

29 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
NYNarges Yousefpour
Narges Yousefpour
HMHabibollah Mahmoodzadeh
Habibollah Mahmoodzadeh
RMReihane Mahdavi
Reihane Mahdavi
Mohammad  Reza FattahiMohammad Reza Fattahi
Mohammad Reza Fattahi
AJAmirmohsen Jalaeefar
Amirmohsen Jalaeefar
MAMohammad Abdolahad
Mohammad Abdolahad
Background: The primary objective of this research is to propose an intra-operative tumor detection probe calibrated on human models of gastrointestinal (G.I.) cancers, enabling real-time scanning of dissected masses. Methods: Electrical Gastrointestinal Cancer Detection (EGCD) measures impedimetric characteristics of G.I. masses using a handpiece probe and a needle-based head probe. Impedance Phase Slope (IPS) and impedance magnitude (Z1kHz) are extracted as the classification parameters. EGCD was tested on palpable G.I. masses and compared to histopathology results. Results: Calibration was carried out on 120 GI mass samples. Considering pathological results as the gold standard, most cancer masses showed Z1kHz between 100 Ω and 2500 Ω while their IPS was between −15 and −1. The EGCD total sensitivity and specificity of this categorization in G.I. cancer patients with palpable tumors were 86.4% and 74.4%, respectively (p-value < 0.01). Conclusion: EGCD scoring can be used for 3D scanning of palpable tumors in G.I. tumors during surgery, which can help clarify the tumors’ pathological response to neoadjuvant chemotherapy or the nature of intra-operative newly found G.I. tumors for the surgeon to manage their surgical procedure better.

5 January 2014 in Iranian Red Crescent Medical Journal
Verified
Journal Article
Open access
PDF file
MSMojtaba Salarifar
Mojtaba Salarifar
MMMehdi Mousavi
Mehdi Mousavi
NYNarges Yousefpour
Narges Yousefpour
ENEbrahim Nematipour
Ebrahim Nematipour
SKSeyed Ebrahim Kassaian
Seyed Ebrahim Kassaian
YGYaser Genab
Yaser Genab
Background: Before primary percutaneous coronary intervention (PCI) in patients with ST elevation myocardial infarction (STEMI), it is not clear whether a routine early administration of glycoprotein IIb/IIIa inhibitors in the emergency ward is beneficial or their administration in selected cases in the catheterization laboratory. Objectives: The present randomized clinical trial sought to investigate whether an earlier administration of Tirofiban could exert any impact on TIMI grade 3 flows and ST resolution in the electrocardiography of patients with STEMI before primary PCI. Materials and Methods: Patients with STEMI within twelve hours of symptom commencement were included if primary PCI was planned to be performed within ninety minutes of admission and excluded if they had contraindications for Tirofiban. Seventy patients were randomized to receive 25 μg/kg of bolus Tirofiban early in the emergency ward (the early Tirofiban group) in three minutes and 70 did not receive Tirofiban (the control group). The primary endpoint of the study was a Thrombolysis in Myocardial Infarction (TIMI) grade 3 flows on the initial angiogram. The study is registered as IRCT201105126463N1 in: www.irct.ir. Results: The study population had a mean age of 57.17 ± 10.09 years and included 79.3 % males. TIMI grade 3 flow was seen in 15 (21.4 %) patients of the Tirofiban group and 7 (10 %) of the control group (P = 0.06, odds ratio = 0.407, and 95 % confidence interval = 0.155-1.072). Complete ST resolution was seen in 30 (42.9 %) patients of the Tirofiban group and 34 (48.6 %) of the control group (P = 0.5). Conclusion: Although TIMI grade 3 flows trended to be higher in the patients who received early Tirofiban in the emergency ward, the difference did not constitute statistical significance and possible benefits, therefore, require further clarification. Keywords: Myocardial Infarction; Tirofiban; Percutaneous Coronary Intervention; Angiography