Nariaki Okamoto

Dr. Nariaki Okamoto

research fellow
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2022 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
MAMahdi Al-Taher
Mahdi Al-Taher
NONariaki Okamoto
Nariaki Okamoto
DMDidier Mutter
Didier Mutter
LSLaurents P. S. Stassen
Laurents P. S. Stassen
JMJacques Marescaux
Jacques Marescaux
BDBernard Dallemagne
Bernard Dallemagne

14 November 2022 in Cancers
Verified
Journal Article
Open access
PDF file
EFEmanuele Felli
Emanuele Felli
LCLorenzo Cinelli
Lorenzo Cinelli
EBELISA BANNONE
ELISA BANNONE
FGFabio Giannone
Fabio Giannone
EMEdoardo Maria Muttillo
Edoardo Maria Muttillo
Michele DianaMichele Diana
Michele Diana
Ischemia-reperfusion injury during major hepatic resections is associated with high rates of post-operative complications and liver failure. Real-time intra-operative detection of liver dysfunction could provide great insight into clinical outcomes. In the present study, we demonstrate the intra-operative application of a novel optical technology, hyperspectral imaging (HSI), to predict short-term post-operative outcomes after major hepatectomy. We considered fifteen consecutive patients undergoing major hepatic resection for malignant liver lesions from January 2020 to June 2021. HSI measures included tissue water index (TWI), organ hemoglobin index (OHI), tissue oxygenation (StO2%), and near infrared (NIR). Pre-operative, intra-operative, and post-operative serum and clinical outcomes were collected. NIR values were higher in unhealthy liver tissue (p = 0.003). StO2% negatively correlated with post-operative serum ALT values (r = −0.602), while ΔStO2% positively correlated with ALP (r = 0.594). TWI significantly correlated with post-operative reintervention and OHI with post-operative sepsis and liver failure. In conclusion, the HSI imaging system is accurate and precise in translating from pre-clinical to human studies in this first clinical trial. HSI indices are related to serum and outcome metrics. Further experimental and clinical studies are necessary to determine clinical value of this technology.

15 September 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
NONariaki Okamoto
Nariaki Okamoto
MRMaría Rita Rodríguez-Luna
María Rita Rodríguez-Luna
VBValentin Bencteux
Valentin Bencteux
MAMahdi Al-Taher
Mahdi Al-Taher
LCLorenzo Cinelli
Lorenzo Cinelli
Michele DianaMichele Diana
Michele Diana
Complete mesocolic excision (CME), which involves the adequate resection of the tumor-bearing colonic segment with “en bloc” removal of its mesocolon along embryological fascial planes is associated with superior oncological outcomes. However, CME presents a higher complication rate compared to non-CME resections due to a higher risk of vascular injury. Hyperspectral imaging (HSI) is a contrast-free optical imaging technology, which facilitates the quantitative imaging of physiological tissue parameters and the visualization of anatomical structures. This study evaluates the accuracy of HSI combined with deep learning (DL) to differentiate the colon and its mesenteric tissue from retroperitoneal tissue. In an animal study including 20 pig models, intraoperative hyperspectral images of the sigmoid colon, sigmoid mesentery, and retroperitoneum were recorded. A convolutional neural network (CNN) was trained to distinguish the two tissue classes using HSI data, validated with a leave-one-out cross-validation process. The overall recognition sensitivity of the tissues to be preserved (retroperitoneum) and the tissues to be resected (colon and mesentery) was 79.0 ± 21.0% and 86.0 ± 16.0%, respectively. Automatic classification based on HSI and CNNs is a promising tool to automatically, non-invasively, and objectively differentiate the colon and its mesentery from retroperitoneal tissue.

2 December 2021 in Cancers
Verified
Journal Article
Open access
PDF file
LCLorenzo Cinelli
Lorenzo Cinelli
Eric FelliEric Felli
Eric Felli
LBLuca Baratelli
Luca Baratelli
SSSilvère Ségaud
Silvère Ségaud
ABAndrea Baiocchini
Andrea Baiocchini
Michele DianaMichele Diana
Michele Diana
Anastomotic leakage (AL) is a serious complication occurring after esophagectomy. The current knowledge suggests that inadequate intraoperative perfusion in the anastomotic site contributes to an increase in the AL rate. Presently, clinical estimation undertaken by surgeons is not accurate and new technology is necessary to improve the intraoperative assessment of tissue oxygenation. In the present study, we demonstrate the application of a novel optical technology, namely Single Snapshot imaging of Optical Properties (SSOP), used to quantify StO2% in an open surgery experimental gastric conduit (GC) model. After the creation of a gastric conduit, local StO2% was measured with a preclinical SSOP system for 60 min in the antrum (ROI-A), corpus (ROI-C), and fundus (ROI-F). The removed region (ROI-R) acted as ischemic control. ROI-R had statistically significant lower StO2% when compared to all other ROIs at T15, T30, T45, and T60 (p < 0.0001). Local capillary lactates (LCLs) and StO2% correlation was statistically significant (R = −0.8439, 95% CI −0.9367 to −0.6407, p < 0.0001). Finally, SSOP could discriminate resected from perfused regions and ROI-A from ROI-F (the future anastomotic site). In conclusion, SSOP could well be a suitable technology to assess intraoperative perfusion of GC, providing consistent StO2% quantification and ROIs discrimination.

1 September 2020 in Journal of Laparoendoscopic & Advanced Surgical Techniques
Verified
Journal Article
Closed access
MAMahdi Al-Taher
Mahdi Al-Taher
NONariaki Okamoto
Nariaki Okamoto
Eric FelliEric Felli
Eric Felli
VAVincent Agnus
Vincent Agnus
Manuel BarberioManuel Barberio
Manuel Barberio
MDMichele Diana
Michele Diana
Background: Iatrogenic ureteral injury is one of the feared complications during intrapelvic surgery. There are limited data on the use of novel near-infrared fluorescence (NIRF) imaging dyes for the purpose of noninvasive ureteral visualization in robot-assisted laparoscopic surgery (RALS). In this study, we evaluated the feasibility of NIRF imaging of the ureter using the IRDye® 800BK dye as the fluorescence dye and a robotic platform with Firefly™ technology as an imaging system. Materials and Methods: An intravenous dose of 0.15 mg/kg was administered in 3 pigs and NIRF imaging was performed for a total duration of 60 minutes. The intraoperative video recordings were analyzed to determine fluorescence intensities and the target-to-background ratio (TBR). Results: In all included animals, a clear delineation of the ureter was achieved from 5 minutes after dye administration until the end of the study. During this time period, the ureter was clearly distinguishable from its surroundings and no statistical differences in TBR were observed. Conclusion: The IRDye 800BK dye, a novel NIRF dye currently undergoing clinical translation, is a promising contrast agent used for noninvasive ureteral imaging, which has the potential to be valuable during RALS.

6 May 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MAMahdi Al-Taher
Mahdi Al-Taher
TPTim Pruimboom
Tim Pruimboom
RSRutger M. Schols
Rutger M. Schols
NONariaki Okamoto
Nariaki Okamoto
NBNicole D. Bouvy
Nicole D. Bouvy
MDMichele Diana
Michele Diana
Intraoperative indocyanine green (ICG) fluorescence angiography has gained popularity and acceptance in many surgical fields for the real-time assessment of tissue perfusion. Although vasopressors have the potential to preclude an accurate assessment of tissue perfusion, there is a lack of literature with regards to its effect on ICG fluorescence angiography. An experimental porcine model was used to expose the small bowel for quantitative tissue perfusion assessment. Three increasing doses of norepinephrine infusion (0.1, 0.5, and 1.0 µg/kg/min) were administered intravenously over a 25-min interval. Time-to-peak fluorescence intensity (TTP) was the primary outcome. Secondary outcomes included absolute fluorescence intensity and local capillary lactate (LCL) levels. Five large pigs (mean weight: 40.3 ± 4.24 kg) were included. There was no significant difference in mean TTP (in seconds) at baseline (4.23) as compared to the second (3.90), third (4.41), fourth (4.60), and fifth ICG assessment (5.99). As a result of ICG accumulation, the mean and the maximum absolute fluorescence intensity were significantly different as compared to the baseline assessment. There was no significant difference in LCL levels (in mmol/L) at baseline (0.74) as compared to the second (0.82), third (0.64), fourth (0.60), and fifth assessment (0.62). Increasing doses of norepinephrine infusion have no significant influence on bowel perfusion using ICG fluorescence angiography.