Naseer Tawfeeq Alwan

Dr. Naseer Tawfeeq Alwan

Northern Technical University, Mosul, Nīnawá, Iraq
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
NANaseer Tawfeeq Alwan
Naseer Tawfeeq Alwan
SSS.E. Shcheklein
S.E. Shcheklein
OAObed M. Ali
Obed M. Ali

1 October 2021 in Inventions
Verified
Journal Article
Open access
PDF file
Ephraim AgyekumEphraim Agyekum
Ephraim Agyekum
SEEPANA PRAVEENKUMARSEEPANA PRAVEENKUMAR
SEEPANA PRAVEENKUMAR
NANaseer Tawfeeq Alwan
Naseer Tawfeeq Alwan
VVVladimir Ivanovich Velkin
Vladimir Ivanovich Velkin
SSSergey Evgenevich Shcheklein
Sergey Evgenevich Shcheklein
Salam J. YaqoobSalam J. Yaqoob
Salam J. Yaqoob
A photovoltaic (PV) module’s electrical efficiency depends on the operating temperature of the cell. Electrical efficiency reduces with increasing PV module temperature which is one of the drawbacks of this technology. This is due to the negative temperature coefficient of a PV module which decreases its voltage significantly while the current increases slightly. This study combines both active and passive cooling mechanisms to improve the electrical output of a PV module. A heat sink made up of aluminum fins and an ultrasonic humidifier were used to cool the panel. The ultrasonic humidifier was used to generate a humid environment at the rear side of the PV module. The cooling process in the study was able to reduce the temperature of the panel averagely by 14.61 °C. This reduction led to a 6.8% improvement in the electrical efficiency of the module. The average power of 12.23 W was recorded for the cooled panel against 10.87 W for the referenced module. In terms of water consumption, a total of 1.5 L was approximately consumed during the whole experimental process due to evaporation. In effect, the proposed cooling approach was demonstrated as effective.

24 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SEEPANA PRAVEENKUMARSEEPANA PRAVEENKUMAR
SEEPANA PRAVEENKUMAR
Aminjon Gulahmadzoda (Gulakhmadov)Aminjon Gulahmadzoda (Gulakhmadov)
Aminjon Gulahmadzoda (Gulakhmadov)
Ephraim AgyekumEphraim Agyekum
Ephraim Agyekum
NANaseer Tawfeeq Alwan
Naseer Tawfeeq Alwan
VVVladimir Ivanovich Velkin
Vladimir Ivanovich Velkin
XCXi Chen
Xi Chen
As is already known, solar photovoltaic (PV) technology is a widely accepted technology for power generation worldwide. However, it is scientifically proven that its power output decreases with an increase in the temperature of the PV module. Such an important issue is controlled by adopting a number of cooling mechanisms for the PV module. The present experimental study assesses the effect of a fanless CPU heat pipe on the performance of a PV module. The experiment was conducted in June in real weather conditions in Yekaterinburg, Russian Federation. The comparative analysis of two PV panels (i.e., cooled, and uncooled) based on the electrical energy, exergy performance, economic, embodied energy and energy payback (5E) for the two systems is presented and discussed. The key results from the study are that the average temperature reduction from the cooling process is 6.72 °C. The average power for the cooled panel is 11.39 W against 9.73 W for the uncooled PV panel; this represents an increase of 1.66 W for the cooled module. Moreover, the average improvements in the electrical efficiency, and embodied energy recorded for a cooled PV panel 2.98%, and 438.52 kWh, respectively. Furthermore, the calculations of the levelized cost of energy (LCE) for the cooled PV panel indicate that it can range from 0.277–0.964 USD/kWh, while that for the uncooled PV panel also ranges from 0.205–0.698 USD/kWh based on the number of days of operation of the plant.

22 January 2022 in Electronics
Verified
Journal Article
Open access
PDF file
MAMuthanna Mohammed Awad
Muthanna Mohammed Awad
OKOmer Khalil
Omer Khalil
Obed Majeed AliObed Majeed Ali
Obed Majeed Ali
NANaseer Tawfeeq Alwan
Naseer Tawfeeq Alwan
Salam J. YaqoobSalam J. Yaqoob
Salam J. Yaqoob
AAAdel Fahad Alrasheedi
Adel Fahad Alrasheedi
The target of the current study was to review and analyze the research activities of previous studies on cooling techniques for thermal photovoltaic (PV) systems using phase-change materials. These materials have the ability to absorb and release certain amounts of potential heat energy by changing their state from phase to phase (solid–liquid) within a small temperature range. These materials have been used to regulate and lower the temperature, increase the efficiency, and extend the life of solar cells. A host of improvements have been made to phase-changing materials through the combined utilization of phase-change materials and fins in addition to nanoscale fluids to enhance electrical efficiency. When using PCMs, the thermal, electrical, and overall efficiency improved by 26.87%, 17.33%, and 40.59%, respectively. The addition of nanomaterials increased phase-change materials’ specific heat capacity and thermal conductivity, thus reducing the plate temperature and increasing the electrical efficiency. It was found that using of nanoparticles together with a microcapsule had better performance in terms of energy efficiency. Studies indicated that variable phase materials were not used because of their high cost and lack of stable operational design. Therefore, the effect of phase-change materials on PV/thermal (PVT) system performance needs further investigation and study.

18 October 2021 in Inventions
Verified
Journal Article
Open access
PDF file
Ephraim AgyekumEphraim Agyekum
Ephraim Agyekum
SEEPANA PRAVEENKUMARSEEPANA PRAVEENKUMAR
SEEPANA PRAVEENKUMAR
NANaseer Tawfeeq Alwan
Naseer Tawfeeq Alwan
VVVladimir Ivanovich Velkin
Vladimir Ivanovich Velkin
Tomiwa AdebayoTomiwa Adebayo
Tomiwa Adebayo
The electrical performance of a photovoltaic (PV) module is hugely affected by its temperature. This study proposed a passive cooling mechanism for the cooling of a PV panel. The proposed cooling system is made up of a combination of aluminum fins and paraffin wax integrated at the PV panel’s rear side. The average temperature for the cooled panel for the entire period of the experiment is 36.62 °C against 48.75 °C for the referenced PV module. This represents an average reduction of 12.13 °C for the cooled panel. The average power for the cooled panel is 12.19 W against 10.95 W for the referenced module which is 11.33% improvement. The electrical efficiencies for the cooled panel and the referenced modules are 14.30% and 13.60%, respectively, representing an improvement of 5.15% in the electrical efficiency. The cooled solar PV module had an average exergy efficiency of 7.99% compared to 5.61% for the referenced module. In terms of the economics, the results from the computations show that LCOE of the cooled panel can range between 0.198 and 0.603 $/kWh, while that of the referenced module ranges from 0.221–0.671 $/kWh depending on the number of days it operates.

1 October 2021 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
NANaseer Tawfeeq Alwan
Naseer Tawfeeq Alwan
SSSergey Evgenevich Shcheklein
Sergey Evgenevich Shcheklein
Obed Majeed AliObed Majeed Ali
Obed Majeed Ali