Natalia Zamora-Martínez

Dr. Natalia Zamora-Martínez

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Medicina Oral Patología Oral y Cirugia Bucal
Verified
Journal Article
Open access
Natalia Zamora-MartínezNatalia Zamora-Martínez
Natalia Zamora-Martínez
JLJm. Llamas
Jm. Llamas
RCRosa Cibrián
Rosa Cibrián
JGJ. Gandia
J. Gandia
VPV. Paredes
V. Paredes
Objectives: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The first step must be to study the characteristics of these devices in terms of accuracy and reliability of the most commonly used landmarks. The aims were 1- To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2- To determine which of those landmarks are more vs. less reliable and 3- To introduce planes of reference so as to create cephalometric analyses appropriated to the 3D reality. Study design: Fifteen patients who had a CBCT (i-CAT®) as a diagnostic register were selected. To assess the reproducibility on landmark location and the differences in the measurements of two observers at different times, 41 landmarks were defined on the three spatial axes (X,Y,Z) and located. 3.690 measurements were taken and, as each determination has 3 coordinates, 11.070 data were processed with SPSS® statistical package. To discover the reproducibility of the method on landmark location, an ANOVA was undertaken using two variation factors: time (t1, t2 and t3) and observer (Ob1 and Ob2) for each axis (X, Y and Z) and landmark. The order of the CBCT scans submitted to the observers (Ob1, Ob2) at t1, t2, and t3, were different and randomly allocated. Multiple comparisons were undertaken using the Bonferroni test. The intra- and inter-examiner ICC´s were calculated. Results: Intra- and inter-examiner reliability was high, both being ICC ≥ 0.99, with the best frequency on axis Z. Conclusions: The most reliable landmarks were: Nasion, Sella, Basion, left Porion, point A, anterior nasal spine, Pogonion, Gnathion, Menton, frontozygomatic sutures, first lower molars and upper and lower incisors. Those with less reliability were the supraorbitals, right zygion and posterior nasal spine.

1 September 2011 in The Angle Orthodontist
Verified
Journal Article
Closed access
Natalia Zamora-MartínezNatalia Zamora-Martínez
Natalia Zamora-Martínez
JLJose M. Llamas
Jose M. Llamas
RCRosa Cibrián
Rosa Cibrián
JGJose L. Gandia
Jose L. Gandia
VPVanessa Paredes
Vanessa Paredes
Objective: To assess whether the values of different measurements taken on three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) are comparable with those taken on two-dimensional (2D) images from conventional lateral cephalometric radiographs (LCRs) and to examine if there are differences between the different types of CBCT software when taking those measurements. Material and Methods: Eight patients were selected who had both an LRC and a CBCT. The 3D reconstructions of each patient in the CBCT were evaluated using two different software packages, NemoCeph 3D and InVivo5. An observer took 10 angular and 3 linear measurements on each of the three types of record on two different occasions. Results: Intraobserver reliability was high except for the mandibular plane and facial cone (from the LCR), the Na-Ans distance (using NemoCeph 3D), and facial cone and the Ans-Me distance (using InVivo5). No statistically significant differences were found for the angular and linear measurements between the LCRs and the CBCTs for any measurement, and the correlation levels were high for all measurements. Conclusion: No statistically significant differences were found between the angular and linear measurements taken with the LCR and those taken with the CBCT. Neither were there any statistically significant differences between the angular or linear measurements using the two CBCT software packages.

1 October 2015 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
EDEva Dalmau
Eva Dalmau
Natalia Zamora-MartínezNatalia Zamora-Martínez
Natalia Zamora-Martínez
Beatriz Tarazona-AlvarezBeatriz Tarazona-Alvarez
Beatriz Tarazona-Alvarez
JGJose L. Gandia
Jose L. Gandia
VPVanessa Paredes
Vanessa Paredes

2 July 2021 in Medicina
Verified
Journal Article
Open access
PDF file
Natalia Zamora-MartínezNatalia Zamora-Martínez
Natalia Zamora-Martínez
Vanessa Paredes-GallardoVanessa Paredes-Gallardo
Vanessa Paredes-Gallardo
Verónica García-SanzVerónica García-Sanz
Verónica García-Sanz
JFJose Luis Gandia Franco
Jose Luis Gandia Franco
Beatriz Tarazona-AlvarezBeatriz Tarazona-Alvarez
Beatriz Tarazona-Alvarez
Background and objectives: Although the main objective of any orthodontic treatment is to correct malocclusion, a range of psychosocial and/or esthetic factors drive patients to undergo orthodontic treatment. The aim of the present study was to analyze variations in oral health-related quality of life (OHRQL) levels in patients undergoing orthodontic treatment by means of four types of appliances: fixed buccal metal brackets, fixed buccal esthetic/ceramic brackets, fixed lingual brackets, and clear aligners. Material and Methods: The study sample comprised 120 patients aged 18 to 68 years who attended the Orthodontic department at the Dental Clinic of the University of Valencia. The Index of Orthodontic Treatment Need (IOTN) was used to measure orthodontic treatment need. Each patient completed three different intervals of the 14-item Oral Health Impact Profile (OHIP-14): before treatment (T0); six months after placing the orthodontic appliances (T1) and at the end of orthodontic treatment (T2). Results: All groups suffered a reduction in quality of life from T0 to T1 except the metal bracket group which presented the same level for the functional limitation domain (p = 1.000), the lingual bracket group for the psychological discomfort domain (p = 1.000) and clear aligner group for the physical disability domain (p = 0.118) and psychological disability domain (p = 1.000). Nevertheless, quality of life for most domains was similar in all groups at the end of treatment (T2). Conclusions: Patients underwent a significant reduction in quality of life during treatment in comparison with their pre-treatment condition but showed significant improvements at the end of treatment.

1 January 2017 in The Angle Orthodontist
Verified
Journal Article
Closed access
LALuela Aranitasi
Luela Aranitasi
Beatriz Tarazona-AlvarezBeatriz Tarazona-Alvarez
Beatriz Tarazona-Alvarez
Natalia Zamora-MartínezNatalia Zamora-Martínez
Natalia Zamora-Martínez
JGJose Luis Gandía
Jose Luis Gandía
VPVanessa Paredes
Vanessa Paredes
Objectives: To quantify the prevalence of cervical vertebrae anomalies and to analyze any association between them and skeletal malocclusions or head posture positions in the same study. Materials and Methods: Two hundred forty patients who were attending the Department of Orthodontics of the University of Valencia for orthodontic treatment were selected and divided into three groups: skeletal Class I (control group, 0° <ANB < 4°), Class II (ANB ≥ 4°), and Class III (ANB ≤ 0°) according to ANB Steiner angle. The morphology of the first five cervical vertebrae was analyzed with cone beam computed tomography to identify any anomalies. Intra- and interobserver error methods were calculated. Results: Dehiscence and fusion of one unit (both 23.3%) and partial cleft (11.7%) were the most frequent anomalies, while occipitalization was the least common (3.3%). Dehiscence anomaly was observed when the control group was compared with Classes II and III and partial cleft anomaly when Class I was compared with Class III. Furthermore, NSBa and ss-N-sm/ANB angles were associated with partial cleft anomaly, while NSL/NL angle and extended head posture were associated with fusion anomaly. Conclusions: Fusion, dehiscence, and partial cleft were the most frequent cervical vertebrae anomalies. Dehiscence and partial cleft were found to present statistically significant differences between Class I and Classes II and III. Cervical vertebrae anomalies and head posture were associated with fusion.

6 June 2017 in Oral Radiology
Verified
Journal Article
Closed access
PDF file
YGYolanda Gómez
Yolanda Gómez
Verónica García-SanzVerónica García-Sanz
Verónica García-Sanz
Natalia Zamora-MartínezNatalia Zamora-Martínez
Natalia Zamora-Martínez
Beatriz Tarazona-AlvarezBeatriz Tarazona-Alvarez
Beatriz Tarazona-Alvarez
CBCarlos Bellot-Arcís
Carlos Bellot-Arcís
VPVanessa Paredes-Gallardo
Vanessa Paredes-Gallardo