Ngo Minh Khoa

Dr. Ngo Minh Khoa

Quy Nhon University
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
NKNgo Minh Khoa
Ngo Minh Khoa
Le Van DaiLe Van Dai
Le Van Dai
The detection, mitigation, and classification of power quality (PQ) disturbances have been issues of interest in the power system field. This paper proposes an approach to detect and classify various types of PQ disturbances based on the Stockwell transform (ST) and decision tree (DT) methods. At first, the ST is developed based on the moving, localizing, and scalable Gaussian window to detect five statistical features of PQ disturbances such as the high frequency of oscillatory transient, distinction between stationary and non-stationary, the voltage amplitude oscillation around an average value, the existence of harmonics in a disturbance signal, and the root mean square voltage at the internal period of sag, swell or interruption. Then, these features are classified into nine types, such as normal, sag, swell, interruption, harmonic, flicker, oscillatory transient, harmonic voltage sag, and harmonic voltage swell by using the DT algorithm that is based on a set of rules with the structure “if…then’’. This proposed study is simulated using MATLAB simulation. The IEEE 13-bus system, the recorded real data based on PQube, and the experiment based on the laboratory environment are applied to verify the effectiveness.

9 September 2018 in Energies
Verified
Journal Article
Open access
PDF file
NKNgo Minh Khoa
Ngo Minh Khoa
DTDoan Duc Tung
Doan Duc Tung
The flexible alternating current transmission systems (FACTS) have been widely used in modern power systems. Because of the presence of the FACTS devices, distance relays in transmission lines may inaccurately locate fault locations. Therefore, it is significant to find a mechanism for locating fault in transmission lines connected to FACTS in which a static var compensator (SVC) is investigated in this work. Based on the development of a phasor measurement unit (PMU) with global positioning system (GPS), this paper proposes a new method for calculating apparent impedance seen by the distance relay location while a short-circuit fault occurs in a transmission line connected the SVC to the midpoint of the line. According to the method, sampled voltage and current measurement at the relay and SVC locations are synchronized using PMUs and the synchronized measurements are then used to calculate a new apparent impedance and to locate the fault location in the line. The method in this paper has the capability for fast calculation and it also has the robustness for identifying different fault types in power systems. Matlab/Simulink software is applied to simulate the study results and to evaluate the correctness of the modeling and effectiveness of the proposed method for locating fault in this paper.

1 May 2013
Verified
Conference Paper
Closed access
NKNgo Minh Khoa
Ngo Minh Khoa
DVDinh Thanh Viet
Dinh Thanh Viet
NHNguyen Huu Hieu
Nguyen Huu Hieu
This paper proposes a new method to classify power quality disturbances using wavelet transform and K-nearest neighbor classifier. New features of power quality disturbances are extracted from discrete wavelet transform then using K-nearest neighbor classifier to classify these disturbances according to the features. Block diagram of the proposed method has been shown in this paper. Performance of the proposed method is trained and verified with power quality disturbances generated by Matlab software. The classification accuracy for these disturbances has been presented and shows that the proposed method is doing well in classifying these types of power quality disturbances.

1 January 2022 in International Journal of Electrical and Electronic Engineering & Telecommunications
Verified
Journal Article
Open access
NKNgo Minh Khoa
Ngo Minh Khoa
DTDoan Duc Tung
Doan Duc Tung
Le Van DaiLe Van Dai
Le Van Dai
This paper presents an architecture of the Doubly-Fed Induction Generator based on Wind Energy Conversion System (DFIG-WECS) to study with the Low Voltage Ride Through (LVRT) capability. The proposed architecture consists of three main parts namely the wind turbine, electric generator, control systems. The wind turbine and gearbox are modeled by a servo motor driven by using an inverter system. The electric generator uses the Wound Rotor Induction Generator (WRIG). The control system composes of the rotor-side converter (RSC) and the grid-side converter (GSC). The integration of the digital signal processor (DSP) with the Simulink/Matlab software of the vector control scheme is implemented to control both RSC and GSC. Besides, to protect the overcurrent of the generator’s rotor and overvoltage of the DC-link, the crowbar and chopper circuits and the logical scheme between the crowbar and the RSC are also proposed. To approve the control algorithms implemented in DSP as hardware in the loops, the proposed 0.8kW DFIG-WESC system has been performed under the experimental environment considering LVRT requirement in German grid code.

25 March 2021 in Archives of Electrical Engineering
Verified
Journal Article
Closed access
PDF file
NKNgo Minh Khoa
Ngo Minh Khoa
Le Van DaiLe Van Dai
Le Van Dai
DTDoan Duc Tung
Doan Duc Tung
NTNguyen An Toan
Nguyen An Toan
This paper proposes an advanced Internet of Things (IoT) system for measuring, monitoring, and recording some power quality (PQ) parameters. The proposed system is designed and developed for both hardware and software. For the hardware unit, three PZEM-004T modules with non-invasive current transformer (CT) sensors are used to measure the PQ parameters and an Arduino WeMos D1 R1 ESP8266 microcontroller is used to receive data from the sensors and send this data to the server via the internet. For the software unit, an algorithm using Matlab software is developed to send measurement data to the ThingSpeak cloud. The proposed system can monitor and analyse the PQ parameters including frequency, root mean square (RMS) voltage, RMS current, active power, and the power factor of a low-voltage load in real-time. These PQ parameters can be stored on the ThingSpeak cloud during the monitoring period; hence the standard deviation in statistics of the voltage and frequency is applied to analyse and evaluate PQ at the monitoring point. The experimental tests are carried out on low-voltage networks 380/220 V. The obtained results show that the proposed system can be usefully applied for monitoring and analysing chosen PQ parameters in micro-grid solutions.

1 August 2017 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
NKNgo Minh Khoa
Ngo Minh Khoa
NHNguyen Huu Hieu
Nguyen Huu Hieu
DVDinh Thanh Viet
Dinh Thanh Viet
This paper focuses on analyzing and evaluating impact of a Static Var Compensator (SVC) on the measured impedance at distance protection relay location on power transmission lines. The measured impedance at the relay location when a fault occurs on the line is determined by using voltage and current signals from voltage and current transformers at the relay and the type of fault occurred on the line. The MHO characteristic is applied to analyze impact of SVC on the distance protection relay. Based on the theory, the authors in this paper develop a simulation program on Matlab/Simulink software to analyze impact of SVC on the distance protection relay. In the power system model, it is supposed that the SVC is located at mid-point of the transmission line to study impact of SVC on the distance relay. The simulation results show that SVC will impact on the measured impedance at the relay when the fault occurs after the location of the SVC on the power transmission line.