While many studies on fused filament fabrication (FFF)-printed polymers focus on ultimate tensile strength or failure analysis, the elastic region of the stress–strain curve is frequently overlooked. However, in most engineering applications, components operate well within the elastic range. In mechanical joints, support frames, and other load-bearing structures, stiffness and elastic response are more critical than post-failure behavior, as these properties determine system performance during standard operating conditions before any damage occurs. This study examines the elastic properties of acrylonitrile butadiene styrene (ABS) components fabricated via FFF, with a focus on the impact of printing orientation and nozzle temperature. Tensile tests were performed according to ISO 527-2:1993, and the results were compared to those of milled ABS parts (referred to as FT). Two print orientations were studied: XT, where the layers are oriented perpendicular to the loading direction, and ZT, where the layers are aligned parallel to the loading direction (load-aligned). The study reveals that printing orientation has a significant impact on mechanical behavior. The specimens printed in the ZT orientation exhibited superior elastic modulus and tensile strength compared to the XT specimens and also outperformed the milled FT parts. At 245 °C, the ZT specimens achieved an average tensile strength of 41.0 MPa, substantially higher than the FT’s 31.1 MPa. Moreover, the ZT had approximately 12.6% higher elastic moduli than the FT (1.97 GPa ZT compared to 1.74 GPa FT). Although the FT parts showed higher strain at break, the ZT-printed parts demonstrated a stiffness and strength that suggest their viability as replacements for machined components in load-bearing applications.
Thrombosis commonly develops in the left atrial appendage of patients with atrial fibrillation. The formation of blood clots in atrial appendage is a complex process, which depends on the shape of the appendage, the velocity of blood flow, the concentrations of red blood cells, platelets, and coagulation, among other factors. In this work, we present a new methodology to identify the key factors contributing to clot formation in the left atrial appendage during atrial fibrillation. The new methodology combines computed tomography imaging, computational fluid dynamics, mesh processing, and multiphase thrombosis modeling. We begin by running simulations to investigate flow patterns inside the left atrial appendages with realistic geometries. Our simulations suggest that at the entrance of the left atrial appendage, the flow forms vortices, which can intrude inside the appendage depending on the phases of the cardiac cycle. Next, we introduce blood coagulation and consider different scenarios corresponding to physiological values of blood flow velocity, geometry of the left atrial appendage, and hematocrit values. Numerical results suggest that the chances of clot formation are higher in the “cactus” geometry than in the “chicken-wing” one, in agreement with the literature. Furthermore, they suggest that slower flow circulation facilitates the development of a clot in the depth of the left atrial appendage. Slower blood movement also favors the procoagulant activity of platelets, while faster flow circulation enhances the procoagulant effect from erythrocytes. Finally, our simulations show that increased hematocrit upregulates the generation of fibrin polymer, regardless of flow velocity.
Atomic force microscopy (AFM) is widely used to quantify mechanical properties, typically Young’s modulus, by fitting force–indentation data with various mathematical contact models. However, results across laboratories often diverge, and the causes remain unresolved. Here, we interrogate the methodology by which mechanical properties are defined in AFM indentation and identify key limitations of the Hertz model, the standard model for determining mechanical properties, notably that the contact radius is not directly determined, which limits the accuracy of the estimated Young’s modulus. We hypothesize that this inference systematically overestimates the true tip–sample contact, which inflates the contact area and thereby underestimates Young’s modulus. This bias is amplified under large indentation conditions, which are frequently used in soft-material studies. To isolate and clarify the issue, we focus on a well-characterized polymer, polyvinyl chloride (PVC), using it as a controlled testbed for contact radius overestimation. Our analysis is focused on the contact radius and Hertz-based extraction of Young’s modulus. We determined the contact radius and Young’s modulus using AFM with two different probes: a sphere with a 20 nm radius (SPHERE20) and a sphere with a 2 µm radius (SPHERE2000). The results were compared to macroscopic data obtained using a standard measurement (ISO 527-1:2019) of Young’s modulus. The contact was modeled using finite element analysis (FEA). The dependence of the contact radius on the indentation was compared to the Hertz model. The results from FEA fit corrected contact radius values, and it is smaller by 15.46% (SPHERE20) and 57.9% (SPHERE2000) than those calculated by the Hertz model.
31 August 2021 in Nonlinear Analysis Modelling and Control
Journal provides a multidisciplinary forum for scientists, researchers and engineers involved in research and design of nonlinear processes and phenomena, including the nonlinear modelling of phenomena of the nature.
20 October 2023 in Mathematical Modelling and Analysis
The dimension reduction for the viscous flows in thin tube structures leads to equations on the graph for the macroscopic pressure with Kirchhoff type junction conditions in the vertices. Non-Newtonian rheology of the flow generates nonlinear equations on the graph. A new numerical method for second order nonlinear differential equations on the graph is introduced and numerically tested.
An asymptotic ansatz for the solution of the axisymmetric problem of interaction between a thin cylindrical elastic tube and a viscous fluid filling the thin interior of the elastic tube was recently introduced and justified by G. Panasenko and R. Stavre. The thickness of the elastic medium () and that of the fluid domain () are small parameters with , while the scale of the longitudinal characteristic size is of order one. At the same time, the magnitude of the stiffness and density of the elastic tube may be large or finite parameters with respect to the viscosity and density of the fluid when the characteristic time is of order one. This ansatz can be considered as a Poiseuille-type solution for the fluid–structure interaction problem. Its substitution to the Stokes fluid–elastic wall coupled problem generates a one-dimensional model. We present a numerical experiment comparing this model with the solution of the full-dimensional fluid–structure interaction problem.