Aneta Nowak-Michta

Dr. Aneta Nowak-Michta

Cracow University of Technology, Kraków, Małopolskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Procedia Engineering
Verified
Journal Article
Open access
Aneta Nowak-MichtaAneta Nowak-Michta
Aneta Nowak-Michta
The influence of water-binder ratio on de-icing salt scaling of hardened concretes with siliceous fly ash addition is analysed in the paper. The analysis made on the basis of 56 cycles scaling Borås test of air-entrained concretes. The levels of water-binder ratio (w/b): 0.45 and 0.38, the partial replacement of cement with fly ash (0, 20, 35, 50% mass of cement), and kind of siliceous fly ash in three categories of loss on ignition A, B and C were variable in concrete mixes. The results show that apart from air-entraining, which was the sufficient condition to ensure freeze-thaw resistance, also the lowest value of water-binder ratio is necessarily to ensure de-icing salt scaling resistance of fly ash concretes. Loss on ignition of fly ash has significant influence on resistance to scaling only in air-entrained concretes with 0.45 water-binder ratio

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
Aneta Nowak-MichtaAneta Nowak-Michta
Aneta Nowak-Michta
One of the criteria used to achieve frost resistant concrete is to obtain appropriate parameters of porosity structure in the hardened concrete. Polish requirements in this regard are not defined by standards. There is only a requirement in terms of the Spacing Factor for air-entraining admixtures contained in EN 934-2. The standard EN 206 to ensure frost resistance of concretes requires in exposure classes XF2-XF4 air content in fresh concretes at least 4% without verification of the porosity structure in the hardened concrete. The technical specifications for paving concretes and bridges usually contain requirements for parameters of porosity structures based on international requirements. Air entraining process of concrete mixtures is complex and depends on many parameters. The analysis of porosity structures in hardened concretes, despite the required frost resistance of concrete, often do not give satisfactory results. Analysis of the results indicates that the reason is inadequate pores sizes in the concretes. Thus, an attempt of explanation of influences of one of the parameters affecting the air entraining process – consistencyof concrete mixes (quantity of superplasticizer) on the porosity structure in the hardened concrete. The research programme was performed on eight series of air-entraining and non-air-entraining concretes with a variable content of superplasticizer. The basic composition and air-entraining admixtures content in air-entraining concrete mixtures were constant. The results showed that with the increase of the content of superplasticizer (with increasing fluidity) air content decreases and the pores sizes changed

9 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
Aneta Nowak-MichtaAneta Nowak-Michta
Aneta Nowak-Michta
A side effect of using modified polycarboxylates to liquefy a concrete mix is additional pores in the concrete. They change the air void system in hardened concretes, and can be used to evaluate the freeze–thaw resistance of concretes. The purpose of this study is to determine the impact of the abovementioned quantitative and qualitative parameters on the freeze–thaw resistance of concretes. The research program was performed on eight sets of air-entraining and non-air-entraining concretes with a variable content of superplasticizer based on modified polycarboxylates. The basic composition of and air-entraining admixture content in the air-entraining concrete mixtures were held constant. Pore structure tests were performed according to EN 480-11. Scaling resistance was determined according to PKN-CEN/TS 12390-9. The results showed that as the content of modified polycarboxylates increased, the pore structure was adversely affected, and, consequently, the air void parameters deteriorated. At the same time, the freeze–thaw resistance of the non-air-entraining concretes decreased. The pores sizes also changed. As the fluidity increased, the specific surface area decreased, and, consequently, the spacing factor increased. The air-entraining concretes, despite the deterioration in the pore structure due to the modified polycarboxylates, were found to be very good quality concretes after 56 freeze–thaw cycles in the presence of 3% NaCl.

24 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
Aneta Nowak-MichtaAneta Nowak-Michta
Aneta Nowak-Michta
The values of the air void parameters in hardened concrete (spacing factor L ≤ 0.200 mm and micro air content A300 ≥ 1.5%), determined on the basis of the Powers model, in concretes produced today do not always guarantee the frost resistance of the concrete, especially when in surface impact with the participation of de-icing agents. The literature indicates that the modified polycarboxylates used to liquefy concrete mixes are one of the factors involved in changing the air void system; therefore, the aim of the article was to determine the dependence of the air void parameters and the resistance to scaling of concretes liquefied to a constant consistency by the use of modified polycarboxylates in the spectrum of variability of the ratio w/c = 0.53 ÷ 0.30. In the research program, twelve concrete mixes were made with a constant proportion of aggregate and paste: six air-entrained—with a constant air content of 5.5 ± 0.5%—and six non-air-entrained. The air void parameters were determined in accordance with EN 480-11, while the resistance to scaling was determined in accordance with CEN/TS 12390-9 and assessed according to the criteria of SS 137244. The analysis of the test results showed that liquefaction with modified polycarboxylates did not affect the w/c limit values, enabling obtaining concretes resistant to scaling. They are, respectively, 0.35 in the non-air-entrained concretes and 0.50 in the air-entrained concretes with an air content of 5.5 ± 0.5. Moreover, the commonly used criterion for ensuring the frost resistance of air-entrained concretes, L ≤ 0.200 mm and A300 ≥ 1.5%, requires supplementing with the minimum value of the w/c ≤ 0.50.

23 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Aneta Nowak-MichtaAneta Nowak-Michta
Aneta Nowak-Michta
Arkadiusz KwiecienArkadiusz Kwiecien
Arkadiusz Kwiecien
JMJagoda Michta
Jagoda Michta
Currently, in Europe, producers of building materials are implementing innovative solutions that provide a chance for the widespread construction of zero-emission and zero-energy build-ings. However, they encounter legal barriers related to the lack of standardization procedures enabling the rapid placing of innovative construction products on the market. The European project Horizon 2020: Measuring Envelope products and systems contributing to the next gener-ation of healthy nearly Zero Energy Buildings (MEZeroE), is to support producers of innovative envelope products used in zero-energy buildings, including in the field of certification, CE marking and placing them relatively quickly on the market. The article presents one of the research procedures developed and tested by Pilot Measurement & Verification Lines (PM&VL7) as part of the MEZeroE project for FLEX&ROBUST polyurethane flexible connectors. This procedure takes into account applicable legal requirements regarding CE marking and also indicates a certification path for this type of products.

1 May 2017 in ACI Materials Journal
Verified
Journal Article
Closed access
PDF file
Aneta Nowak-MichtaAneta Nowak-Michta
Aneta Nowak-Michta