Nuna G. Costa

Ms. Nuna G. Costa

University of Minho, Guimarães, Braga, Portugal
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2022 in Biosensors
Verified
Journal Article
Open access
NCNuna G. Costa
Nuna G. Costa
Joana AntunesJoana Antunes
Joana Antunes
APAntonio Jose Paleo
Antonio Jose Paleo
ARAna Maria Rocha
Ana Maria Rocha
The continued focus on improving the quality of human life has encouraged the development of increasingly efficient, durable, and cost-effective products in healthcare. Over the last decade, there has been substantial development in the field of technical and interactive textiles that combine expertise in electronics, biology, chemistry, and physics. Most recently, the creation of textile biosensors capable of quantifying biometric data in biological fluids is being studied, to detect a specific disease or the physical condition of an individual. The ultimate goal is to provide access to medical diagnosis anytime and anywhere. Presently, alcohol is considered the most commonly used addictive substance worldwide, being one of the main causes of death in road accidents. Thus, it is important to think of solutions capable of minimizing this public health problem. Alcohol biosensors constitute an excellent tool to aid at improving road safety. Hence, this review explores concepts about alcohol biomarkers, the composition of human sweat and the correlation between alcohol and blood. Different components and requirements of a biosensor are reviewed, along with the electrochemical techniques to evaluate its performance, in addition to construction techniques of textile-based biosensors. Special attention is given to the determination of biomarkers that must be low cost and fast, so the use of biomimetic materials to recognize and detect the target analyte is turning into an attractive option to improve electrochemical behavior.

19 November 2024 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Open access
NCNuna G. Costa
Nuna G. Costa
CBCláudia S. Buga
Cláudia S. Buga
Natália HomemNatália Homem
Natália Homem
APAntonio Jose Paleo
Antonio Jose Paleo
VSVítor Sencadas
Vítor Sencadas
ARA.M. Rocha
A.M. Rocha

5 August 2025 in Electrochimica Acta
Verified
Journal Article
Open access
NCNuna G. Costa
Nuna G. Costa
CVCaio R. Vanoni
Caio R. Vanoni
ABAline Barros
Aline Barros
CSCarla Silva
Carla Silva
AGArturo Gonzalez
Arturo Gonzalez
ARA.M. Rocha
A.M. Rocha

24 January 2024 in Processes
Verified
Journal Article
Open access
PDF file
NCNuna G. Costa
Nuna G. Costa
DFDavid da Silva Freitas
David da Silva Freitas
ABAline Barros
Aline Barros
Carla SilvaCarla Silva
Carla Silva
Joana AntunesJoana Antunes
Joana Antunes
ARAna Maria Rocha
Ana Maria Rocha
A solid-phase microextraction (SPME) injection gas chromatography was validated with the flame ionization detection method (GC-FID) using a capillary column to detect ethanol. The method was used to determine ethanol in fluids with biomedical, clinical, and forensic importance, including water, phosphate-buffered saline (PBS), and artificial sweat. The strategy produced good peak resolution and showed a linear correlation between the concentration and peak areas for ethanol in all matrices. The inter- and intra-day precisions of the method were below 15.5% and 6.5%, respectively, varying according to the matrix. The method achieved detection limits below 1.3 mg/L, varying according to the matrix. Lower limits were obtained for the aqueous solution (0.22 mg/L), followed by the PBS solution (0.96 mg/L), and finally, the sweat solution (1.29 mg/L). This method is easy to perform and suitable for use in routine clinical biochemistry and forensic laboratories, allowing ethanol detection at lower concentrations using lower temperature and time of extraction, when compared with other studies.