Tairkhan Dautov

Prof. Dr. Tairkhan Dautov


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
ADAinara Darbayeva
Ainara Darbayeva
TDTairkhan Dautov
Tairkhan Dautov
GZGulnur Zhakhina
Gulnur Zhakhina
BDBakyt Duisenbayeva
Bakyt Duisenbayeva
RSRoza Suleimenova
Roza Suleimenova
GOGaliya Orazova
Galiya Orazova
Radiology services play a vital role in modern healthcare, yet disparities in access and concerns about occupational radiation exposure remain understudied in many countries, including Kazakhstan. This study evaluates national trends in diagnostic imaging services, workforce distribution, and radiation-related anxiety among medical personnel. We analyzed national diagnostic imaging infrastructure and workforce data from 2018–2024. Individual radiation exposure data (n = 177) were obtained from dosimetry records in Astana’s medical facilities. Additionally, a cross-sectional survey (n = 324) was conducted using the Spielberger–Hanin Anxiety Scale to assess radiation-related anxiety and associated factors. Between 2018 and 2024, the number of CT rooms in Kazakhstan more than doubled from 162 to 358 (+121%), while X-ray examinations declined from 20.6 to 14.6 million (−29.2%) and fluorography dropped by 67.7%. CT scans increased over threefold, from 491,738 to 1.6 million. Radiologists grew from 3529 to 4511 (+27.8%), and ultrasound doctors from 1396 to 2178 (+56.1%). Interventional physicians had the highest quarterly radiation dose (0.65 ± 0.58 mSv, p = 0.001). Among radiology professionals, 32% reported anxiety related to occupational exposure. Anxiety was significantly associated with not using aprons (58% vs. 27%, p < 0.001), lack of dosimeter use (27% vs. 12%, p = 0.001), and inadequate safety training (27% vs. 6%, p < 0.001). Spielberger–Hanin scores ≥ 45 indicated high levels of situational (58%) and personal (56%) anxiety in this group. Kazakhstan’s diagnostic radiology capacity has grown rapidly, especially in CT availability, yet regional disparities and occupational anxiety remain critical concerns. Targeted workforce distribution, improved protective practices, and enhanced radiation safety education are urgently needed.

27 February 2023 in Journal of Clinical Medicine of Kazakhstan
Verified
Journal Article
Open access
PDF file
BKBauyrzhan Kaliyev
Bauyrzhan Kaliyev
RRRaushan Rakhimzhanova
Raushan Rakhimzhanova
TDTairkhan Dautov
Tairkhan Dautov
LBLazzat Bastarbekova
Lazzat Bastarbekova
ZMZhanar Moldakhanova
Zhanar Moldakhanova
AAAyan Abdrakhmanov
Ayan Abdrakhmanov
Objective: Atrial fibrillation is strongly associated with stroke and accounts for 60% of cardioembolic stroke. Assessing thromboembolic risk is important for patients with atrial fibrillation. Approximately 90% of all thrombus are localized in the left atrium appendage (LAA). This study aimed to determine the efficacy of cardiac computed tomography (CT) for LAA thrombus detection. Material and methods: This retrospective study included 292 patients. LAA thrombus was confirmed or excluded by cardiac CT with the reference to transesophageal echocardiography (TEE). We excluded patients with allergic reactions to iodide, increased creatinine levels, thyroid disease (hyperthyroidism), pregnancy, and age <18 years. Results: According to the cardiac CT, 103 of 292 people had LAA thrombus, while according to TEE, only 48 of patients had LAA thrombus. The sensitivity and specificity of CT were 97.7% and 77%, respectively. The sensitivity and specificity of the CT was higher in 2016–2020, when the delayed phase was added to the standard protocol, compared to 2012–2015 years. Older age, higher BMI, higher CHA2DS2-VASc and HAS-BLED scores, and larger LA and LVESV were significantly associated with LAA thrombus detection on cardiac CT. Higher LVESV and LVEDV indexes (LVESVI and LVEDVI) and lower LV ejection fraction measured by TEE were also predictors of LAA thrombus detection by cardiac CT. Conclusion: Our findings show that cardiac CT has high sensitivity and specificity for excluding or confirming LAA thrombus, and can also be exclusively used to determine the presence or absence of a thrombus.

1 January 2024 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
TDTairkhan Dautov
Tairkhan Dautov
ZKZhanar Kozhakhmetova
Zhanar Kozhakhmetova
BKBauyrzhan Kaliyev
Bauyrzhan Kaliyev
NZNurmakhan Zholshybek
Nurmakhan Zholshybek
BYBibissara Yerekesh
Bibissara Yerekesh
Dautov T, et al. Korean J Radiol. 2024 Jun;25(6):508-510. https://doi.org/10.3348/kjr.2024.0270

30 June 2023 in Kardiologiia
Verified
Journal Article
Closed access
PDF file
BKBauyrzhan Bakhytovich Kaliyev
Bauyrzhan Bakhytovich Kaliyev
RRRaushan Ibzhanovna Rakhimzhanova
Raushan Ibzhanovna Rakhimzhanova
Valentin SinitsynValentin Sinitsyn
Valentin Sinitsyn
TDTairkhan Dautov
Tairkhan Dautov
AAAyan Abdrakhmanov
Ayan Abdrakhmanov
Aim The study aimed to determine the efficacy of cardiac computed tomography angiography (CCTA) for diagnosing left atrial appendage (LAA) thrombus before catheter ablation with the patient in the left lateral decubitus position and, also, to evaluate the risk factors for thrombus formation. Material and methods This retrospective, cohort study included 101 patients with atrial fibrillation. All patients underwent transthoracic echocardiography (TTE) and left lateral decubitus CCTA. Transesophageal echocardiography (TEE) was performed to confirm or exclude LAA thrombus. Patients with allergic reactions to iodinated contrast media, increased serum creatinine, hyperthyroidism, pregnancy, and age<18 years were excluded. The CHA2‑DS2‑VASc and HAS-BLED scores were calculated for each patient. Results All LAA thrombi detected on CCTA were confirmed by TEE. Higher CHA2‑DS2‑VASc, HAS-BLED scores, enlarged LA, and the anteroposterior dimension of the left atrium were significantly associated with the presence of LAA thrombus. A LAA cauliflower shape was a predictor of thrombus. An increase of LAA volume by 1 ml increased the chances of LAA thrombus and cerebral ischemic infarct by 2 %. The growth of the LAA anteroposterior diameter by 1 cm increased the risk of LAA thrombus by 190 % and of cerebral infarct by 78 %. An increase in the CHA2DS2‑VASc score by 1 point increased the risk of thromboembolism and cerebral infarction by 12 %. Conclusions CCTA performed in the left lateral decubitus position of the patient is an optimal screening tool to detect or exclude LAA thrombus before catheter ablation because of atrial fibrillation. CCTA has predictive value for risk of thrombosis formation in LAA.

31 March 2023 in Oncologia i Radiologia Kazakhstana
Verified
Journal Article
Closed access
FBF. Bayembaev
F. Bayembaev
RRR. Rakhimzhanova
R. Rakhimzhanova
TDTairkhan Dautov
Tairkhan Dautov
ASA. Saduakasova
A. Saduakasova
ATA. Temirbekov
A. Temirbekov
Relevance: Positron emission tomography combined with computed tomography (PET/CT) is a young and promising technique for lymphoproliferative diseases’ primary detection, staging, and evaluation of the treatment results. However, at this stage of nuclear medicine development, some shortcomings in PET/CT diagnostics of lymphomas using 18Fluorodeoxyglucose (F18-FDG) affect its reliability to a certain extent. The study aimed to evaluate the physical and technical weaknesses of F18-FDG PET/CT in diagnosing lymphomas and review the analytical methods that affect opinion accuracy. Methods: The articles on the use of F18-FDG PET/CT in diagnosing lymphomas, its reliability, and methods for optimizing were searched in the PUBMED database for 2012-2022. Results: One of the main shortcomings of F18-FDG PET/CT in diagnosing lymphomas is the Deauville 5-point scale, which does not fully meet clinical requirements. This scale has some disadvantages, including low inter-reader agreement and an unreliable reference organ for F18-FDG accumulation. Mathematical algorithms for correction to the patient’s weight also require optimization. Conclusion: Some of the existing deficiencies can be improved at the software level and through educating staff about the importance of changing the SUV calculation method. However, other deficiencies, such as classifications that do not meet clinical requirements, require more efforts at the level of international experts and much more in-depth study of this issue to avoid such shortcomings of new staging methods. However, even considering all the shortcomings described, at the moment, PET/CT with F18-FDG is one of the most reliable modalities available, both for the initial detection and for evaluating the therapy effectiveness in patients with lymphomas.

31 March 2023 in Oncologia i Radiologia Kazakhstana
Verified
Journal Article
Closed access
FBF. Bayembaev
F. Bayembaev
RRR. Rakhimzhanova
R. Rakhimzhanova
TDTairkhan Dautov
Tairkhan Dautov
ASA. Saduakasova
A. Saduakasova
ATA. Temirbekov
A. Temirbekov
Relevance: Positron emission tomography combined with computed tomography (PET/CT) is a young and promising technique for lymphoproliferative diseases’ primary detection, staging, and evaluation of the treatment results. However, at this stage of nuclear medicine development, some shortcomings in PET/CT diagnostics of lymphomas using 18Fluorodeoxyglucose (F18-FDG) affect its reliability to a certain extent. The study aimed to evaluate the physical and technical weaknesses of F18-FDG PET/CT in diagnosing lymphomas and review the analytical methods that affect opinion accuracy. Methods: The articles on the use of F18-FDG PET/CT in diagnosing lymphomas, its reliability, and methods for optimizing were searched in the PUBMED database for 2012-2022. Results: One of the main shortcomings of F18-FDG PET/CT in diagnosing lymphomas is the Deauville 5-point scale, which does not fully meet clinical requirements. This scale has some disadvantages, including low inter-reader agreement and an unreliable reference organ for F18-FDG accumulation. Mathematical algorithms for correction to the patient’s weight also require optimization. Conclusion: Some of the existing deficiencies can be improved at the software level and through educating staff about the importance of changing the SUV calculation method. However, other deficiencies, such as classifications that do not meet clinical requirements, require more efforts at the level of international experts and much more in-depth study of this issue to avoid such shortcomings of new staging methods. However, even considering all the shortcomings described, at the moment, PET/CT with F18-FDG is one of the most reliable modalities available, both for the initial detection and for evaluating the therapy effectiveness in patients with lymphomas.