A buried quad junction (BQJ) photodetector has been designed and fabricated with a high-voltage CMOS process. It implements four vertically stacked p-n junctions with four different spectral responses. This feature allows high spectral discriminating ability, greater than both conventional buried double junction and buried triple junction detectors. In this paper, we propose a SPICE-like model, based on the physical properties of the device structure. The proposed model has been integrated in EDA software. It could be used for rapid and reliable design of system on chip, integrating the BQJ sensor, and its signal processing. The analytical expressions of the four BQJ photocurrents, as well as dark currents, have been developed. The spectral characteristics of the photodetector, computed with the proposed model, have been compared with those from TCAD simulations and experimental measurements. The analytical is close to the measurement with an average error on spectral responses in the range of 3%-17%, depending on the considered junction.

16 November 2020 in IEEE Circuits and Systems Magazine
Verified
Journal Article
Closed access
GGGabriel Gagnon-Turcotte
Gabriel Gagnon-Turcotte
GBGuillaume Bilodeau
Guillaume Bilodeau
OTOlivier Tsiakaka
Olivier Tsiakaka
Benoit GosselinBenoit Gosselin
Benoit Gosselin
The future of brain research lies in the application of new technologies drawing from the latest developments in biology, physics and engineering to advance our understanding of how this complex organ processes, integrates and transfers information. Among these, optogenetics is a groundbreaking technology that allows using light to selectively activate neurons in the cortex of transgenic animals, usually mice, to observe its effect in large biological networks. A new research paradigm drawing from these advances consists of synchronizing optogenetic stimulation with electrophysiology recordings, to close the loop and to regulate the neural microcircuits, or to repair them. Such an approach holds promise to accelerate the development of new therapeutics against brain diseases by enabling entirely new experimental research scenarios with freely behaving animal models. As a result, the development of advanced wireless microelectronic implantable systems to elicit, extract and process brain data in real time has become a source of significant interest. This paper reviews the design challenges and the state-of-the-art technology in this field. We present the design of a complete electro-optic device for preforming optogenetics and multichannel electrophysiology in a closed-loop (CL) system with live neurons. We cover the design of the different CMOS integrated building blocks involved in this system to perform photostimulation and multichannel neural recording in parallel. We describe advanced hardware strategies to perform action potential (AP) detection, neural data compression and AP sorting in real-time, over several parallel recording channels for enabling real-time CL neural control. Finally, we present CL experimental results obtained in vivo with an electro-optic prototype.

10 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
OTOlivier Tsiakaka
Olivier Tsiakaka
Benoit GosselinBenoit Gosselin
Benoit Gosselin
SFSylvain FERUGLIO
Sylvain FERUGLIO
Pulse oximetry enables oxygen saturation estimation ( S p O 2) non-invasively in real time with few components and modest processing power. With the advent of affordable development kits dedicated to the monitoring of biosignals, capabilities once reserved to hospitals and high-end research laboratories are becoming accessible for rapid prototyping. While one may think that medical-grade equipment differs greatly in quality, surprisingly, we found that the performance requirements are not widely different from available consumer-grade components, especially regarding the photodetection module in pulse oximetry. This study investigates how the use of candidate light sources and photodetectors for the development of a custom S p O 2 monitoring system can lead to inaccuracies when using the standard computational model for oxygen saturation without calibration. Following the optical characterization of selected light sources, we compare the extracted parameters to the key features in their respective datasheet. We then quantify the wavelength shift caused by spectral pairing of light sources in association with photodetectors. Finally, using the widely used approximation, we report the resulting absolute error in S p O 2 estimation and show that it can lead up to 8% of the critical 90–100% saturation window.

21 April 2018 in Microelectronics Journal
Verified
Journal Article
Closed access
OTOlivier Tsiakaka
Olivier Tsiakaka
SFSylvain FERUGLIO
Sylvain FERUGLIO

19 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NMnicolas MAINARD
nicolas MAINARD
OTOlivier Tsiakaka
Olivier Tsiakaka
SLSonglin LI
Songlin LI
JDJulien Denoulet
Julien Denoulet
KMKarim Messaoudene
Karim Messaoudene
SFSylvain FERUGLIO
Sylvain FERUGLIO
The spinal cord is a major structure of the central nervous system allowing, among other things, the transmission of afferent sensory and efferent motor information. During spinal surgery, such as scoliosis correction, this structure can be damaged, resulting in major neurological damage to the patient. To date, there is no direct way to monitor the oxygenation of the spinal cord intraoperatively to reflect its vitality. This is essential information that would allow surgeons to adapt their procedure in case of ischemic suffering of the spinal cord. We report the development of a specific device to monitor the functional status of biological tissues with high resolution. The device, operating with multiple wavelengths, uses Near-InfraRed Spectroscopy (NIRS) in combination with other additional sensors, including ElectroNeuroGraphy (ENG). In this paper, we focused primarily on aspects of the PhotoPlethysmoGram (PPG), emanating from four different light sources to show in real time and record biological signals from the spinal cord in transmission and reflection modes. This multispectral system was successfully tested in in vivo experiments on the spinal cord of a pig for specific medical applications.

1 August 2015
Verified
Conference Paper
Closed access
OTOlivier Tsiakaka
Olivier Tsiakaka
MTMehdi Terosiet
Mehdi Terosiet
OROlivier Romain
Olivier Romain
AHAymeric Histace
Aymeric Histace
HBHabib Benali
Habib Benali
SFSylvain Feruglio
Sylvain Feruglio
Little is known about the processes occurring after Spinal Cord damage. Whether permanent or recoverable, those processes have not been precisely characterized because their mechanism is complex and information on the functioning of this organ are partial. This study demonstrates the feasibility of Spinal Cord activity monitoring using Near Infra-Red Spectroscopy in a pig animal model. This animal has been chosen because of its comparable size and its similarities with humans. In the first step, optical characterization of the Spinal Cord tissues was performed in different conditions using a spectrophotometer. Optical Density was evaluated between 3.5 and 6.5 in the [500; 950] nm range. Secondly, adapted light sources with custom probes were used to observe autonomic functions in the spine. Results on the measured haemodynamics at rest and under stimulation show in real time the impact of a global stimulus on a local section of the Spinal Cord. The photoplethysmogram signal of the Spinal Cord showed low AC-to-DC ratio (below to 1 %).