Pascal Schirmer

Dr. Pascal Schirmer

University of Hertfordshire
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PSPascal Schirmer
Pascal Schirmer
IMIosif Mporas
Iosif Mporas
The rapid development of technology in the electrical energy sector within the last 20 years has led to growing electric power needs through the increased number of electrical appliances and automation of tasks. In parallel the global climate protection goals, energy conservation and efficient energy management arise interest for reduction of the overall energy consumption. These requirements have led to the recent adoption of smart-meters and smart-grids, as well as to the rise of Load Monitoring (LM) using energy disaggregation, also referred to as Non-Intrusive Load Monitoring (NILM), which enables appliance-specific energy monitoring by only observing the aggregated energy consumption of a household. The real-time information on appliance level can be used to get deeper insights in the origin of energy consumption and to make optimization, strategic load scheduling and demand management feasible. The three main contributions are as follows: First, a generalized up-to-date review of NILM approaches including a high-level taxonomy of NILM methodologies is provided. Second, previously published results are grouped based on the experimental setup which allows direct comparison. Third, the article is accompanied by a software implementation of the described NILM approaches.

11 June 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
PSPascal Schirmer
Pascal Schirmer
IMIosif Mporas
Iosif Mporas
In this paper we evaluate several well-known and widely used machine learning algorithms for regression in the energy disaggregation task. Specifically, the Non-Intrusive Load Monitoring approach was considered and the K-Nearest-Neighbours, Support Vector Machines, Deep Neural Networks and Random Forest algorithms were evaluated across five datasets using seven different sets of statistical and electrical features. The experimental results demonstrated the importance of selecting both appropriate features and regression algorithms. Analysis on device level showed that linear devices can be disaggregated using statistical features, while for non-linear devices the use of electrical features significantly improves the disaggregation accuracy, as non-linear appliances have non-sinusoidal current draw and thus cannot be well parametrized only by their active power consumption. The best performance in terms of energy disaggregation accuracy was achieved by the Random Forest regression algorithm.

6 January 2020 in Entropy
Verified
Journal Article
Open access
PDF file
PSPascal Schirmer
Pascal Schirmer
IMIosif Mporas
Iosif Mporas
Michael ParaskevasMichael Paraskevas
Michael Paraskevas
In this article an energy disaggregation architecture using elastic matching algorithms is presented. The architecture uses a database of reference energy consumption signatures and compares them with incoming energy consumption frames using template matching. In contrast to machine learning-based approaches which require significant amount of data to train a model, elastic matching-based approaches do not have a model training process but perform recognition using template matching. Five different elastic matching algorithms were evaluated across different datasets and the experimental results showed that the minimum variance matching algorithm outperforms all other evaluated matching algorithms. The best performing minimum variance matching algorithm improved the energy disaggregation accuracy by 2.7% when compared to the baseline dynamic time warping algorithm.

16 June 2021 in IEEE Transactions on Emerging Topics in Computational Intelligence
Verified
Journal Article
Closed access
PSPascal Schirmer
Pascal Schirmer
IMIosif Mporas
Iosif Mporas
Non-Intrusive Load Monitoring aims to extract the energy consumption of individual electrical appliances through disaggregation of the total power load measured by a single smart-meter. In this article we introduce Double Fourier Integral Analysis in the Non-Intrusive Load Monitoring task in order to provide more distinct feature descriptions compared to current or voltage spectrograms. Specifically, the high-frequency aggregated current and voltage signals are transformed into two-dimensional unit cells as calculated by Double Fourier Integral Analysis and used as input to a Convolutional Neural Network for regression. The performance of the proposed methodology was evaluated in the publicly available U.K.-DALE dataset. The proposed approach improves the estimation accuracy by 7.2% when compared to the baseline energy disaggregation setup using current and voltage spectrograms.

1 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
PSPascal Schirmer
Pascal Schirmer
IMIosif Mporas
Iosif Mporas
Akbar Sheikh-AkbariAkbar Sheikh-Akbari
Akbar Sheikh-Akbari
A data-driven methodology to improve the energy disaggregation accuracy during Non-Intrusive Load Monitoring is proposed. In detail, the method uses a two-stage classification scheme, with the first stage consisting of classification models processing the aggregated signal in parallel and each of them producing a binary device detection score, and the second stage consisting of fusion regression models for estimating the power consumption for each of the electrical appliances. The accuracy of the proposed approach was tested on three datasets—ECO (Electricity Consumption & Occupancy), REDD (Reference Energy Disaggregation Data Set), and iAWE (Indian Dataset for Ambient Water and Energy)—which are available online, using four different classifiers. The presented approach improves the estimation accuracy by up to 4.1% with respect to a basic energy disaggregation architecture, while the improvement on device level was up to 10.1%. Analysis on device level showed significant improvement of power consumption estimation accuracy especially for continuous and nonlinear appliances across all evaluated datasets.

4 January 2021 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
PSPascal Schirmer
Pascal Schirmer
IMIosif Mporas
Iosif Mporas