Patricia Kwakye-Boateng

Dr. Patricia Kwakye-Boateng

Mechanical Engineering, Accra Technical University, Accra, Greater Accra, Ghana
+2
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
Patricia Kwakye-BoatengPatricia Kwakye-Boateng
Patricia Kwakye-Boateng
Lagouge TartibuLagouge Tartibu
Lagouge Tartibu
Tien-Chien JenTien-Chien Jen
Tien-Chien Jen
The growing need for cooling, combined with the environmental concerns surrounding conventional mechanical vapour compression (MVC) systems, has accelerated research for sustainable cooling solutions driven by low-grade heat. Single-stage dual-bed adsorption chillers (ADCs) using silica gel and water provide a promising approach due to their continuous cooling output, lower complexity, and the use of environmentally safe working fluids. However, limitations in their performance, specifically in the coefficient of performance (COP), cooling capacity (Qcc), and waste heat recovery efficiency (ηe), necessitate improvement through optimization. This study employs statistically validated regression-based objective functions to optimize ten decision variables using the single Grey Wolf Optimizer (GWO) and its multi-objective variant, Muilti-Objective Grey Wolf Optimization (MOGWO), for a silica gel–water single-stage dual-bed ADC. The results from the single-objective optimization showed a maximum coefficient of performance (COP) of 0.697, cooling capacity (Qcc) of 20.76 kW, and waste heat recovery efficiency (ηe) of 0.125. The values from the Pareto-optimal solutions for the MOGWO ranged from 0.5123 to 0.6859 for COP, 12.45 to 20.73 kW for Qcc and 8.24% to 12.48% for ηe, demonstrating superior performance compared to existing benchmarks. A one-at-a-time sensitivity analysis revealed non-linear and non-monotonic impacts of variables, confirming the robustness and physical realism of the MOGWO model. The developed MOGWO framework effectively enhances the performance of the single-stage dual-bed ADC and improves low-grade heat utilization, offering a robust decision-support tool for system design and optimization.

9 July 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Patricia Kwakye-BoatengPatricia Kwakye-Boateng
Patricia Kwakye-Boateng
Lagouge TartibuLagouge Tartibu
Lagouge Tartibu
Tien-Chien JenTien-Chien Jen
Tien-Chien Jen
The growing need for cooling, combined with the environmental concerns surrounding conventional mechanical vapour compression (MVC) systems, has accelerated research for sustainable cooling solutions driven by low-grade heat. Single-stage dual-bed adsorption chillers (ADCs) using silica gel and water offer a promising approach due to their continuous cooling output, lower complexity, and use of environmentally safe working fluids. However, limitations in their performance, specifically in Coefficient of Performance (COP), cooling capacity (Qcc), and waste heat recovery efficiency (ηᴇ), necessitate improvement through optimisation. This study employs regression-based objective functions and optimizes ten decision variables using the Grey Wolf Optimizer (GWO) and its multi-objective variant (MOGWO). Results showed COP values between 0.5123 and 0.6859 and Qcc values from 12.45 to 20.73 kW. A one-at-a-time sensitivity analysis revealed non-linear and non-monotonic impacts of variables, confirming the physical realism of the MOGWO model. The framework effectively enhances ADC performance and low-grade heat utilization.
1

5 January 2026 in Technologies
Verified
Journal Article
Open access
PDF file
Patricia Kwakye-BoatengPatricia Kwakye-Boateng
Patricia Kwakye-Boateng
Lagouge TartibuLagouge Tartibu
Lagouge Tartibu
Tien-Chien JenTien-Chien Jen
Tien-Chien Jen
Growing cooling demand and environmental concerns motivate research into alternative technologies capable of converting low-grade heat into useful cooling. This study proposes a regression-assisted multi-objective optimisation framework using the Ant Lion Optimiser and its multi-objective variant to jointly maximise the coefficient of performance (COP), cooling capacity (Qcc) and waste-heat recovery efficiency (ηe). Pareto-optimal solutions exhibit a one-dimensional ridge in which ηe declines, and COP and Qcc increase simultaneously. Within the explored bounds, non-dominated ranges span COP = 0.674–0.716, Qcc= 18.3–27.5 kW and ηe= 0.118–0.127, with a practical compromise near COP ≈ 0.695, Qcc ≈ 24 kW and ηe ≈ 0.122–0.123. Compared to the typical reported COP band for single-stage silica-gel/water ADCs, the practical compromise solution (COP ≈ 0.695) offers a conservative COP improvement of approximately 16% when benchmarked against COP = 0.6, while the compromise Qcc (Qcc ≈ 24 kW) represents a conservative increase of approximately 20% relative to the upper product-class reference (20 kW). A one-at-a-time sensitivity analysis with re-optimisation identifies the hot- and chilled-water inlet temperatures and exchanger conductance as the dominant decision variables and maps diminishing-return regions. This framework can effectively utilise low-grade heat in future low-carbon buildings and processes, supporting the configuration of ADC systems.

9 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Patricia Kwakye-BoatengPatricia Kwakye-Boateng
Patricia Kwakye-Boateng
Lagouge TartibuLagouge Tartibu
Lagouge Tartibu
Tien-Chien JenTien-Chien Jen
Tien-Chien Jen
Growing cooling demand and environmental concerns surrounding mechanical vapour compression systems motivate research into alternative technologies capable of converting low-grade heat into useful cooling. Silica-gel/water single-stage dual-bed adsorption chillers (ADCs) are promising candidates, however, their design must balance conflicting performance targets. This study proposes a regression-assisted multi-objective optimisation framework for low-grade-heat ADC, combining statistically validated surrogate models with the Ant Lion Optimiser and its multi-objective variant. Three co-equal objectives, coefficient of performance (COP), cooling capacity (Q_cc) and waste-heat recovery efficiency (η_e) are jointly maximised to map an operational envelope for sustainable cooling. Two-dimensional Pareto-optimal solutions exhibit a one-dimensional ridge in which η_e declines, and COP and Q_cc increase simultaneously. Within the explored bounds, non-dominated ranges span COP=0.675–0.717, Q_cc=18.3–27.5 kW and η_e=0.118–0.127, with a practical compromise near COP ≈ 0.695, Q_cc ≈ 24 kW and η_(e )≈ 0.122–0.123. While mass flow rate decisions increase Q_cc at the expense of η_e, a one-at-a-time sensitivity analysis with re-optimisation identifies the hot- and chilled-water inlet temperatures and exchanger conductance as the dominant decision variables and maps diminishing-return regions. The proposed framework can effectively use low-grade heat in future low-carbon buildings and processes and supports the configuration of ADC systems.