Instrumenting wells with distributed acoustic sensors (DASs) and illuminating them with passive or active seismic sources allows precise tracking of temporal variations of direct-wave traveltimes and amplitudes, which can be used to monitor variations in formation stiffness and density. This approach has been tested by tracking direct-wave amplitudes and traveltimes as part of a carbon capture and storage project where a 15 kt supercritical CO2 injection has been monitored with continuous offset vertical seismic profiling using nine permanently mounted surface orbital vibrators acting as seismic sources and several wells instrumented with DAS cables cemented behind the casing. The results indicate a significant (from 15% to 30%) increase of strain amplitudes within the CO2 injection interval, and traveltime shifts of 0.3–0.4 ms below this interval, consistent with full-wave 1.5D numerical simulations and theoretical predictions. The results give independent estimates of the CO2 plume thickness and the associated P-wave velocity reduction.
Induced seismicity is one of the main risks for gigaton‐scale geological storage of carbon dioxide ( ). Thus, passive seismic monitoring is often recommended as a necessary component of the monitoring systems for storage projects, with a particular forcus on risk mitigation. We present the first field study, CO2CRC Otway Project Stage 3 (Victoria, Australia), where distributed acoustic sensing (DAS) enabled high‐precision tracking of the induced seismicity triggered by a small injection and also informed the reservoir models. In 610 days of passive seismic monitoring of the Stage 3 injection, we detected 17 microseismic events (maximum moment magnitude 0.1) using five deep boreholes equipped with enhanced‐sensitivity optical fiber. The DAS array has sensitivity sufficient for detection and location of induced events with in a monitoring borehole located up to 1500 m away. Thanks to the dense spatial sampling by the DAS, we were able to estimate the focal mechanisms for events with ; although the monitoring boreholes provided very limited angular coverage. The main cluster of the events has the same location and source mechanism as the one triggered by the previous injection at the Otway Project site, Stage 2C. Surprizingly, the Stage 2C and Stage 3 events closely followed the actual movement of the saturation plume front (not the pressure front), as observed using controlled‐source reflection seismic images. The nature of the plume‐fault interaction remains unclear, but some alteration of the fault gouge by might be responsible for the faults’ reactivation by the pressure perturbation. Importantly, the seismogenic fault could not be identified in the seismic images and was only revealed by DAS observations, which also demonstrated the signature of fluid–rock interaction, that may control the flow.
Monitoring changes of formation properties along the well bore associated with the presence of carbon dioxide can be important for both tracking the plume inside of the primary containment and detecting leakage into the zone located above the reservoir. This can be achieved with time lapse wireline logging, but this approach requires well intervention and is not always possible. If the well is permanently instrumented with an optical fibre, it can be used as a distributed seismic receiver array to detect gas behind the casing by monitoring changes in amplitude of the seismic waves generated by active or passive seismic sources. Previous research showed the efficacy of this technique using continuous seismic sources. The Stage 3 Otway Project presented an opportunity to test this technique using passive seismic recording, as downhole fibre-optic arrays recorded numerous regional earthquakes over the period of nearly 2 years before, during, and after CO2 injection. Analysis of P-wave amplitudes extracted from these downhole gathers shows a consistent amplitude anomaly at the injection level, visible in all events that occurred after the start of injection. This indicates that the anomaly is caused by changes in elastic properties in the reservoir caused by CO2 saturation. However, extracted amplitudes show significant variability between earthquakes even without subsurface changes; thus, multiple events are required to distinguish the time-lapse anomaly from time-lapse noise. Ubiquity of these events even in a tectonically quiet region (such as Australia) makes this technique a viable and cost-effective option for downhole monitoring.
The 4D surface seismic monitoring is a standard method for reservoir surveillance during the production of hydrocarbons or CO2 injection. However, land 4D seismic acquisition campaigns are often associated with high cost and disruptions to industrial operation or agricultural activities in the area of acquisition. An alternative technique for time-lapse monitoring of the subsurface is the 3D vertical seismic profiling (VSP), which becomes particularly attractive when used with distributed acoustic fiber-optic sensors (DAS) installed in wells. The advantages of 3D DAS VSP include its relatively low cost, minimal footprint on the local area during acquisition, and superior spatial resolution compared to the resolution of geophones. The potential of this technique is explored by processing and analyzing multiwell 3D DAS VSP data acquired at the CO2CRC Otway Project site in Victoria, Australia. The DAS data were recorded using an engineered fiber with enhanced backscattering cemented behind the casing of five wells. The data from each well are processed individually using the same processing flow and then migrated using a 3D migration code tailored to DAS data. Having DAS along the full extent of multiple wells ensures adequate seismic coverage of the area of CO2 injection. The migrated images provide detailed information about the subsurface up to 700 m away from a well and up to 2 km depth. The images are consistent with previously acquired geophone VSP and surface seismic data. The quality of the 3D DAS VSP imaging is comparable or superior to the quality of conventional imaging using geophone data. Therefore, 3D DAS VSP is a demonstrably optimal solution for reservoir monitoring.
Distributed acoustic sensing (DAS) is a promising technology for seismic data acquisition, particularly in downhole applications. However, downhole DAS measurements can be affected by the deployment method of the fibre-optic cable. These effects were explored in a field trial in two wells (one vertical and one deviated) drilled at the Otway International Test Centre. The trial in the vertical well shows that (1) fibre-optic cables cemented behind the casing provide data of the highest quality due to the best coupling to the formation, and (2) tubing-conveyed cable shows only slightly weaker coupling, but the data quality can be severely degraded by source-generated noise. A cable loosely suspended in the deviated well provided data quality comparable to that of the cemented DAS cable. To better understand the nature of the observed effects, the field experiments were supplemented by numerical modelling with a 1.5D full wave reflectivity algorithm (3D wave propagation in a 1D model), where cement, casing and wellbore were represented by infinite vertical layers. The results show that (1) a cement layer has only a slight effect (<5%) on the DAS amplitude; (2) the vertical strain in a liquid-filled borehole is comparable to that in the formation; and (3) the strain amplitude in the cable is of the same order of magnitude both in the formation and in the fluid. The strain in the cable is zero both when the cable’s Poisson’s ratio is zero and when the borehole fluid is air. The results confirm the feasibility of borehole DAS measurements with fibre-optic cables suspended in a borehole liquid (but not gas!).