Truong Quoc Truong

Prof. Dr. Truong Quoc Truong


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2015 in Indian Journal of Microbiology
Verified
Journal Article
Closed access
PDF file
Truong Quoc TruongTruong Quoc Truong
Truong Quoc Truong
DHDo Thi Thu Ha
Do Thi Thu Ha
UVUwe Volker
Uwe Volker
EHElke Hammer
Elke Hammer

1 January 2023 in Journal of Applied Biology & Biotechnology
Verified
Journal Article
Open access
PDF file
TTThuy Thi Thu Trinh
Thuy Thi Thu Trinh
HNHuong Thu Ngo
Huong Thu Ngo
Truong Quoc TruongTruong Quoc Truong
Truong Quoc Truong
Bovine lactoferrin (bLf) has been well characterized as a multifunctional glycoprotein belonging to the transferrin family with antibacterial, antioxidant, anti-tumor, and antiviral activities. The main aim of this study was to determine the feeding strategies in fed-batch fermentation to obtain high-cell density in Pichia pastoris KM71H-3 for production of bLf. During the growth phase, two feeding strategies were performed: (i) Feeding glycerol solution; and (ii) feeding glycerol and nitrogen source solution with a carbon-to-nitrogen ratio of 3:1. In addition, two feeding induction strategies were applied: One-time feeding and continuous feeding with 0.5% of methanol every 24 h. The results showed that the highest cell density at OD600 was 362.67 ± 2.04 when the feeding phase used a mix-feed solution of glycerol and nitrogen sources with a carbon to nitrogen ratio of 3:1 in the 2-L scale. Up-scaled production of lactoferrin from this strain was successfully employed in the 10-L and 100-L bioreactor with the highest OD600 reaching 338.20 ± 3.38 and 375.50 ± 2.98, respectively. For optimal lactoferrin expression, methanol was fed continuously, corresponding to an induced methanol concentration of 0.5% per 24 h. The appropriate induction time was 48 h. This research provides information on cell growth and fed-batch strategies for enhanced bLf production using P. pastoris as a host, which may be applicable to the expression of other proteins from P. pastoris strains.

19 October 2018 in Vietnam Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
Truong Quoc TruongTruong Quoc Truong
Truong Quoc Truong
NPNgọc Thị Phạm
Ngọc Thị Phạm
HNHuong Dieu Nguyen
Huong Dieu Nguyen
ANAnh Thi Ngoc Nguyen
Anh Thi Ngoc Nguyen
Aflatoxins are secondary metabolites mostly produced by Aspergillus flavus and Aspergillus parasiticus and found in agricultural foodstuff such as maize grains, peanuts, animal feeds,... These are toxic and cancerous agents for humans and animals. Among them, aflatoxin B1 is the most consideration due to its highest toxicity and presence in samples. Several methods were developed to detect aflatoxin in food, feed and other foodstuffs such as chromatographic methods (TLC, HPTLC, HPLC), LC-MS/MS, FTIR, RIA, ELISA, SPR, electrochemical, and immunodipstick. Among them only immunodipstick method is compatible for field usage. Therefore, aim of the present study is to determine optimal condition for conjugation of aflatoxin B1 (AFB1) with bovine serum albumin (BSA) to develop a lateral flow immunoassay test strip for detection of aflatoxin B1. Optimal conditions for generating mediate compound of aflatoxin B1 – CMO was investigated: AFB1:CMO ratio of 1:2, reflux temperature of 100oC for 2 hours. Concentration of aflatoxin B1 in reaction was 0.27 µg/µl. Conjugation of AFB1 with CMO was confirmed by thin layer chromatography, HPLC and FT-IR methods. Furthermore, optimal conditions for conjugation of mediate AFB1-CMO derivative with BSA were also investigated. Ratio of AFB1-CMO with BSA was determined as 40:1 and equal to predicted theoretical ratio. Efficient conjugation conditions were 25oC for 2 hours in bicarbonate buffer pH 9.5. Generated conjugate of AFB1-BSA was successfully applied to construct a lateral flow immunoassay test strip for detection of aflatoxin B1

26 January 2024 in Vietnam Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
NHNgo Thu Huong
Ngo Thu Huong
HHHoang Thi Huyen
Hoang Thi Huyen
Truong Quoc TruongTruong Quoc Truong
Truong Quoc Truong
Tetracycline (TC) is a broad-spectrum antibiotic used in the treatment of several infectious diseases. The excessive use of tetracycline antibiotics, especially tetracyclines in livestock, has raised concerns about residues of tetracycline antibiotics in food that may affect consumers' health. It is necessary to develop a rapid test strip for detecting tetracycline antibiotic residues in food and animal feed. This paper presents the suitable conditions for the conjugation of tetracycline to BSA or KLH: molar ratio of TC:BSA/KLH was 25:1, formaldehyde concentration of 5 %, temperature of 4oC and reaction time of 4 hours. The KLH-TC conjugate was used to successfully raise polyclonal antibodies against TC in rabbits. The anti-TC polyclonal antibodies were purified and could be used for the development of the lateral flow immunoassay test strip for the detection of tetracycline.

Verified
Journal Article
Open access
PDF file
CVCuong Viet Vo
Cuong Viet Vo
TNTrang Thu Nguyen
Trang Thu Nguyen
HNHuong Thu Ngo
Huong Thu Ngo
BABui Thi Lan Anh
Bui Thi Lan Anh
TTToan Van Trinh
Toan Van Trinh
Truong Quoc TruongTruong Quoc Truong
Truong Quoc Truong
Neisseria meningitidis is a pathogenic bacterial agent that causes meningococcal meningitis in humans. Developing a rapid and low-cost N. meningitidis detection method is crucial, especially for developing countries. This study focuses on the development of an efficient loop-mediated isothermal amplification (LAMP) method for accurate N. meningitidis identification. A new LAMP primer set was designed, and a LAMP reaction was optimized. The colorimetric detection method was also applied, and the assay characteristics were evaluated using clinical samples. The results demonstrated a specific LAMP reaction for N. meningitidis detection of genotypes A, B, and C, with a limit of detection of 102 cfu/mL, 100% specificity and sensitivity, and a rapid detection time of only 40 min by colorimetric visual inspection. No cross-reactivity with reference strains of Streptococcus pneumoniae, Staphylococcus aureus, Neisseria lactamica, Mycobacterium tuberculosis, and Haemophilus influenzae type b was observed in the LAMP reaction with the new primer set. This result suggests that the LAMP reaction could be a promising tool for developing a rapid N. meningitidis detection method suitable for use in Vietnam and other developing countries.

1 January 2024 in Journal of Applied Biology & Biotechnology
Verified
Journal Article
Open access
PDF file
HNHuong Thu Ngo
Huong Thu Ngo
TNTho Tien Ngo
Tho Tien Ngo
STSon Van Tran
Son Van Tran
YTYen Thu Tran
Yen Thu Tran
HNHien Dang Nguyen
Hien Dang Nguyen
Truong Quoc TruongTruong Quoc Truong
Truong Quoc Truong
Rubella is still considered a dangerous infectious disease, especially for pregnant women. The symptoms of rubella can be similar to those of other illnesses. Therefore, an early and accurate diagnosis of the rubella virus will help doctors make a reasonable treatment plan. This study presents the development and characterization of a novel lateral flow immunochromatographic assay test strip for rapid recognition of rubella virus antigen. Rabbit polyclonal antibodies against the rubella virus were purified with a purity of 95%. Optimal conditions for the production of the main components of a test strip were determined. Anti-rubella virus polyclonal antibodies were physically adsorbed onto the star-shaped gold nanoparticles at the optimal concentration of 1.0 μg/ml at 25°C for 30 min. The amounts of antibody per conjugate pad and immobilized on the test line were 0.2 μg/pad and 4.5 μg/cm, respectively. The properties of the test strip were characterized by testing mock clinical specimens. Reproducibility and repeatability were achieved at 100%. The limit of detection of the test strip was determined to be as low as 5 × 105 virus particles/mL. The test strip did not cross-react with six different potential interfering pathogens. The sensitivity and specificity of the test strip were determined by testing with 400 mock clinical samples and reached 99.5% and 98.5%, respectively. The Kappa statistics (k coefficient = 0.98) showed very good agreement between the generated test strip and real-time PCR results. According to the findings, the test strip can be used as an additional rapid test tool for the detection of the rubella virus.