RODRIGO MORUZZI

Prof. RODRIGO MORUZZI

Sao Paulo State University
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Science of The Total Environment
Verified
Journal Article
Closed access
RODRIGO MORUZZIRODRIGO MORUZZI
RODRIGO MORUZZI
AOAndré L. de Oliveira
André L. de Oliveira
Fabiano Tomazini ConceiçãoFabiano Tomazini Conceição
Fabiano Tomazini Conceição
JGJohn Gregory
John Gregory
Luiza C. CamposLuiza C. Campos
Luiza C. Campos

19 September 2022 in Environmental Pollution
Verified
Journal Article
Closed access
LGLuiza Ostini Goehler
Luiza Ostini Goehler
RODRIGO MORUZZIRODRIGO MORUZZI
RODRIGO MORUZZI
FCFabiano Tomazini da Conceição
Fabiano Tomazini da Conceição
AJAntônio Aparecido Couto Júnior
Antônio Aparecido Couto Júnior
LSLais Galileu Speranza
Lais Galileu Speranza
Luiza C. CamposLuiza C. Campos
Luiza C. Campos

1 February 2018 in Journal of Hydrology
Verified
Journal Article
Closed access
JAJoão Abrantes
João Abrantes
RODRIGO MORUZZIRODRIGO MORUZZI
RODRIGO MORUZZI
ASAlexandre Silveira
Alexandre Silveira
JLJoão L.M.P. de Lima
João L.M.P. de Lima

14 July 2020 in Water
Verified
Journal Article
Open access
PDF file
RODRIGO MORUZZIRODRIGO MORUZZI
RODRIGO MORUZZI
LSLais Galileu Speranza
Lais Galileu Speranza
Fabiano Tomazini ConceiçãoFabiano Tomazini Conceição
Fabiano Tomazini Conceição
SMSuely Teodoro de Souza Martins
Suely Teodoro de Souza Martins
Rosa BusquetsRosa Busquets
Rosa Busquets
Luiza C. CamposLuiza C. Campos
Luiza C. Campos
Stormwater runoff carries pollutants from urban areas to rivers and has the potential to be a main contributing source of microplastics (MPs) to the ecosystem. Stormwater detention reservoirs (SDRs) differ from ponds and lakes in that SDRs retain most particulate matter and they are emptied after storm events. This paper investigates the occurrence of MPs in the SDR of the Alto-Tietê catchment area, Itaim stream in Poá city, São Paulo, Brazil. The MPs found were classified in different categories: shapes (fragment, line/fibre, film/sheet and pellet); size (1 mm); and polymer composition. Results have shown that most of the MPs found in the samples are fragments (57%), followed by pellets (27%), fibres/lines (9%), and then films/sheets (6%). Small particles (<0.5 mm) represented 89% of the total MPs, and this category mainly included fragments (62%) and pellets (30%). MPs were found in a vast variety of shapes and colours, which shows a likely variety of sources. Besides the occurrence of MPs in the stormwater samples, the potential of SDRs as a first sanitary barrier to retain MPs before they reach the ecosystem has been speculated.

1 January 2010 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
RODRIGO MORUZZIRODRIGO MORUZZI
RODRIGO MORUZZI
MRM. A. P. Reali
M. A. P. Reali
This paper aims to investigate the influence of some dissolved air flotation (DAF) process variables (specifically: the hydraulic detention time in the contact zone and the supplied dissolved air concentration) and the pH values, as pretreatment chemical variables, on the micro-bubble size distribution (BSD) in a DAF contact zone. This work was carried out in a pilot plant where bubbles were measured by an appropriate non-intrusive image acquisition system. The results show that the obtained diameter ranges were in agreement with values reported in the literature (10–100 μm), quite independently of the investigated conditions. The linear average diameter varied from 20 to 30 μm, or equivalently, the Sauter (d3,2) diameter varied from 40 to 50 μm. In all investigated conditions, D50 was between 75% and 95%. The BSD might present different profile (with a bimodal curve trend), however, when analyzing the volumetric frequency distribution (in some cases with the appearance of peaks in diameters ranging from 90–100 μm). Regarding volumetric frequency analysis, all the investigated parameters can modify the BSD in DAF contact zone after the release point, thus potentially causing changes in DAF kinetics. This finding prompts further research in order to verify the effect of these BSD changes on solid particle removal efficiency by DAF.

15 March 2023 in Water
Verified
Journal Article
Open access
PDF file
Adriano BressaneAdriano Bressane
Adriano Bressane
AGAna Paula Garcia Goulart
Ana Paula Garcia Goulart
CMCarrie Peres Melo
Carrie Peres Melo
IGIsadora Gurjon Gomes
Isadora Gurjon Gomes
ALAnna Isabel Silva Loureiro
Anna Isabel Silva Loureiro
RTRicardo Fernandes Thomé
Ricardo Fernandes Thomé
Coagulation is the most sensitive step in drinking water treatment. Underdosing may not yield the required water quality, whereas overdosing may result in higher costs and excess sludge. Traditionally, the coagulant dosage is set based on bath experiments performed manually, known as jar tests. Therefore, this test does not allow real-time dosing control, and its accuracy is subject to operator experience. Alternatively, solutions based on machine learning (ML) have been evaluated as computer-aided alternatives. Despite these advances, there is open debate on the most suitable ML method applied to the coagulation process, capable of the most highly accurate prediction. This study addresses this gap, where a comparative analysis between ML methods was performed. As a research hypothesis, a data-driven (D2) fuzzy inference system (FIS) should provide the best performance due to its ability to deal with uncertainties inherent to complex processes. Although ML methods have been widely investigated, only a few studies report hybrid neuro-fuzzy systems applied to coagulation. Thus, to the best of our knowledge, this is the first study thus far to address the accuracy of this non-hybrid data-driven FIS (D2FIS) for such an application. The D2FIS provided the smallest error (0.69 mg/L), overcoming the adaptive neuro-fuzzy inference system (1.09), cascade-correlation network (1.18), gene expression programming (1.15), polynomial neural network (1.20), probabilistic network (1.17), random forest (1.26), radial basis function network (1.28), stochastic gradient tree boost (1.25), and support vector machine (1.17). This finding points to the D2FIS as a promising alternative tool for accurate real-time coagulant dosage in drinking water treatment. In conclusion, the D2FIS can help WTPs to reduce operating costs, prevent errors associated with manual processes and operator experience, and standardize the efficacy with real-time and highly accurate predictions, and enhance safety for the water industry. Moreover, the evidence from this study can assist in filling the gap with the most suitable ML method and identifying a promising alternative for computer-aided coagulant dosing. For further advances, future studies should address the potential of the D2FIS for the control and optimization of other unit operations in drinking water treatment.