Rakesh Kumar Singh

Dr. Rakesh Kumar Singh

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in International Journal of Information Technology
Verified
Journal Article
Closed access
PDF file
Rakesh Kumar SinghRakesh Kumar Singh
Rakesh Kumar Singh
VVVimlesh Verma
Vimlesh Verma

5 November 2025 in Processes
Verified
Journal Article
Open access
PDF file
Rambaboo SinghRambaboo Singh
Rambaboo Singh
RKRamesh Kumar
Ramesh Kumar
RSRavi Shankar
Ravi Shankar
Rakesh Kumar SinghRakesh Kumar Singh
Rakesh Kumar Singh
In this study, the authors demonstrate the development and evaluation of an optimal frequency control controller for an interlinked two-area power system that incorporates Renewable Energy Sources (RESs). In decentralized power grids, the Load Frequency Control (LFC) system allows scheduled tie-line power as well as system frequency to be reimposed to their nominal values. Designing an advanced controller might enhance the functionality of the LFC mechanism. This article illustrates the possible impacts of converter capacitors using the new High-Voltage Direct Current (HVDC) tie-line model as well as the Inertia Emulation Technique (IET). This paper suggests a new adaptive control procedure for the expected LFC mechanism: an ANN-based (PIλ + PIλf) controller. The authors evaluate which control parameters are most effective using a modified version of the Quasi-Opposition-learning-based Reptile Search Algorithm (QORSA) method. Software called MATLAB/Simulink-2015 is used to create this arrangement. The use of established techniques for handling step as well as random load disturbances has enabled an evaluation of the suggested LFC architecture’s efficacy. An IET-based HVDC tie-line reduces overshoot by 100% in Areas 1 and 2 (Area 1 frequency deviation, i.e., ∆f1, as well as Area 2 frequency deviation, i.e., ∆f2). When considering SLD, the suggested controller outperforms the most widely used alternative settings. The IEEE-39 bus system has been changed by the addition of RESs. The IEEE-39 bus system is composed of three control areas. It is confirmed how the IEEE-39 bus system reacts to changes in frequency in Areas 1, 2, and 3. It is illustrated how to use the suggested controller in the modified IEEE-39 bus system, accompanied by real-time load variations. Recent research indicates that the suggested control method is better and more efficient due to its 100% decrease in overshoot in Areas 1 and 2 and quick response time.

22 April 2021
Verified
Book Chapter
Closed access
PDF file
SAShobha Agarwal
Shobha Agarwal
Rakesh Kumar SinghRakesh Kumar Singh
Rakesh Kumar Singh
VVVimlesh Verma
Vimlesh Verma

13 October 2021 in International Journal of System Assurance Engineering and Management
Verified
Journal Article
Closed access
PDF file
Rakesh Kumar SinghRakesh Kumar Singh
Rakesh Kumar Singh
SAShobha Agarwal
Shobha Agarwal
VVVimlesh Verma
Vimlesh Verma