Rakibul Hasan

Mr. Rakibul Hasan

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2026 in Energies
Verified
Journal Article
Open access
PDF file
Rakibul HasanRakibul Hasan
Rakibul Hasan
Majdi MansouriMajdi Mansouri
Majdi Mansouri
JAJURA ARKHANGELSKI
JURA ARKHANGELSKI
Mahamadou Abdou-TankariMahamadou Abdou-Tankari
Mahamadou Abdou-Tankari
Accurate forecasting of energy consumption in sensor-rich environments remains challenging due to strong inter-sensor dependencies, temporal variability, and heterogeneous sensor behavior. This paper proposes a lightweight and interpretable multi-sensor fusion framework for short-term energy consumption forecasting. The heterogeneous sensor dataset is first preprocessed to handle missing values, outliers, and temporal misalignment, followed by synchronization of the multivariate signals on a common timeline to enable consistent learning. The proposed framework systematically investigates multiple strategies for exploiting information from synchronized multi-sensor data without performing explicit feature elimination or time-lag engineering. In particular, three fusion paradigms are considered: (i) Early Fusion, where all sensor measurements are jointly used as input features for a multivariate regression model; (ii) Late Fusion, where individual sensor predictors are trained independently and their outputs are combined using reliability-based weighting; and (iii) an attention-inspired fusion strategy, in which adaptive weights are assigned to sensor-level predictions based on their predictive reliability estimated from training errors and normalized via a softmax function. In addition, classical machine learning models including Random Forest (RF), Support Vector Regression (SVR), and Gradient Boosting (GB) are evaluated under the same experimental conditions to provide a consistent benchmark. Experimental results on a real-world building energy monitoring dataset consisting of nine heterogeneous sensors demonstrate that multi-sensor fusion approaches consistently improve forecasting performance compared to single-model baselines. Among the evaluated strategies, Late Fusion provides stable performance across strongly correlated loads, while the attention-inspired fusion strategy exhibits improved robustness when handling sensors with varying predictive reliability. To ensure robustness and reproducibility, results are reported using multiple chronological validation splits, with performance evaluated in terms of RMSE, MAE, and R2 along with statistical measures including standard deviation and confidence intervals. The proposed framework provides a practical balance between predictive accuracy, interpretability, and computational efficiency, making it suitable for smart building energy management and real-world deployment scenarios.

24 March 2026 in Artificial Intelligence Research and Applications
Verified
Journal Article
Open access
PDF file
JAJURA ARKHANGELSKI
JURA ARKHANGELSKI
Rakibul HasanRakibul Hasan
Rakibul Hasan
Mahamadou Abdou-TankariMahamadou Abdou-Tankari
Mahamadou Abdou-Tankari
GLGilles Lefebvre
Gilles Lefebvre
Accurate 24-hour energy forecasting in smart buildings remains a challenging real-world problem due to the highly non-linear, dynamic, and heterogeneous nature of IoT sensor data. This study extensively expands upon previous research that demonstrated the effectiveness of Bi-LSTM as a univariate predictor. To address existing gaps, we make two primary contributions: (1) developing a multivariate forecasting framework that incorporates eight diverse IoT sensor streams, including HVAC (heat pump) energy consumption and indoor environmental comfort metrics, and (2) benchmarking advanced attention-based architectures, such as the Temporal Fusion Transformer (TFT), optimized for interpretable, high-performance multidimensional time-series forecasting. Using real-world datasets from a multifunctional smart building in France (Pôle Culturel), experiments were conducted over approximately four months (October 23, 2024, to February 27, 2025) at 10-minute intervals. The preprocessing pipeline includes timestamp harmonization, Akima interpolation for non-linear data gaps, outlier correction, and feature scaling. Using MAE, RMSE, MAPE, and R2 as evaluation metrics, the experiments compare a multivariate Bi-LSTM against standard models such as LSTM, GRU, and the TFT. The results indicate that the multivariate Bi-LSTM (R2 = 0.9656) significantly reduces errors compared to univariate approaches, accurately capturing daily trends and peak loads. Furthermore, while the TFT effectively models complex multivariate dependencies (R2 = 0.8130), it demonstrates that attention-based models require specific architectural tuning for medium-scale IoT datasets, providing practical guidance for sustainable, data-driven energy management.