Rambaboo Singh

Mr. Rambaboo Singh

Electrical Engineering, National Institute of Technology Patna, Patna, India

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
Rambaboo SinghRambaboo Singh
Rambaboo Singh
RKRamesh Kumar
Ramesh Kumar
URUtkarsh Raj
Utkarsh Raj
RSRavi Shankar
Ravi Shankar
Frequency regulation (FR) constitutes a fundamental aspect of power system stability, particularly in the context of the growing integration of intermittent renewable energy sources (RES) and electric vehicles (EVs). The load frequency control (LFC) mechanism, essential for achieving FR, is increasingly reliant on communication infrastructures that are inherently vulnerable to cyber threats. Cyberattacks targeting these communication links can severely compromise coordination among smart grid components, resulting in erroneous control actions that jeopardize the security and stability of the power system. In light of these concerns, this study proposes a cyber-physical LFC framework incorporating a fuzzy linear active disturbance rejection controller (F-LADRC), wherein the controller parameters are systematically optimized using the quasi-opposition-based reptile search algorithm (QORSA). Furthermore, the proposed approach integrates a comprehensive cyberattack detection and prevention scheme, employing Haar wavelet transforms for anomaly detection and long short-term memory (LSTM) networks for predictive mitigation. The effectiveness of the proposed methodology is validated through simulations conducted on a restructured power system integrating RES and EVs, as well as a modified IEEE 39-bus test system. The simulation outcomes substantiate the capability of the proposed framework to deliver robust and resilient frequency regulation, maintaining system frequency and tie-line power fluctuations within nominal operational thresholds, even under adverse cyberattack scenarios.

5 November 2025 in Processes
Verified
Journal Article
Open access
PDF file
Rambaboo SinghRambaboo Singh
Rambaboo Singh
RKRamesh Kumar
Ramesh Kumar
RSRavi Shankar
Ravi Shankar
Rakesh Kumar SinghRakesh Kumar Singh
Rakesh Kumar Singh
In this study, the authors demonstrate the development and evaluation of an optimal frequency control controller for an interlinked two-area power system that incorporates Renewable Energy Sources (RESs). In decentralized power grids, the Load Frequency Control (LFC) system allows scheduled tie-line power as well as system frequency to be reimposed to their nominal values. Designing an advanced controller might enhance the functionality of the LFC mechanism. This article illustrates the possible impacts of converter capacitors using the new High-Voltage Direct Current (HVDC) tie-line model as well as the Inertia Emulation Technique (IET). This paper suggests a new adaptive control procedure for the expected LFC mechanism: an ANN-based (PIλ + PIλf) controller. The authors evaluate which control parameters are most effective using a modified version of the Quasi-Opposition-learning-based Reptile Search Algorithm (QORSA) method. Software called MATLAB/Simulink-2015 is used to create this arrangement. The use of established techniques for handling step as well as random load disturbances has enabled an evaluation of the suggested LFC architecture’s efficacy. An IET-based HVDC tie-line reduces overshoot by 100% in Areas 1 and 2 (Area 1 frequency deviation, i.e., ∆f1, as well as Area 2 frequency deviation, i.e., ∆f2). When considering SLD, the suggested controller outperforms the most widely used alternative settings. The IEEE-39 bus system has been changed by the addition of RESs. The IEEE-39 bus system is composed of three control areas. It is confirmed how the IEEE-39 bus system reacts to changes in frequency in Areas 1, 2, and 3. It is illustrated how to use the suggested controller in the modified IEEE-39 bus system, accompanied by real-time load variations. Recent research indicates that the suggested control method is better and more efficient due to its 100% decrease in overshoot in Areas 1 and 2 and quick response time.