Ramita Shah

Ms. Ramita Shah

Electrical Engineering and Computer Science, South Dakota State University, Brookings, Oregon, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
MKMorakot Kaewmanee
Morakot Kaewmanee
LLLarry Leigh
Larry Leigh
Ramita ShahRamita Shah
Ramita Shah
GGGarrison L Gross
Garrison L Gross
Three advanced methodologies were performed during Landsat-9 on orbit and initialization and verification (OIV): Extended Pseudo Invariant Calibration Sites Absolute Calibration Model Double Ratio (ExPAC Double Ratio) and Extended Pseudo Invariant Calibration Sites (EPICS)-based cross-calibration utilizing stable regions in Northern African desert sites (EPICS-NA) and a global scale (EPICS-Global). The development of these three techniques was described using uncertainties analysis. The ExPAC Double Ratio was derived based on the ratio between ExPAC model prediction and satellite measurements for Landsat-8 and Landsat-9. The ExPAC Double Ratio can be performed to determine differences between sensors ranging from visible, red edge, near-infrared, to short-wave infrared wavelengths. The ExPAC Double Ratio and EPICS-based inter-comparison ratio uncertainties were determined using the Monte Carlo Simulation. It was found that the uncertainty levels of 1–2% can be achieved. The EPICS-based cross-calibration results were derived using two targets: EPICS-NA and EPICS-Global, with uncertainties of 1–2.2% for all spectral bands. The inter-comparison results between Landsat-9 and Landsat-8 during the OIV period using the three advanced methods were well within 0.5% for all spectral bands except for the green band, which showed sub 1% agreement.

8 December 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Ramita ShahRamita Shah
Ramita Shah
LLLarry Leigh
Larry Leigh
MKMorakot Kaewmanee
Morakot Kaewmanee
CPCibele Teixeira Pinto
Cibele Teixeira Pinto
The expanded Trend-to-Trend (T2T) cross-calibration technique has the potential to calibrate two sensors in much less time and provides trends on a daily assessment basis. The trend obtained from the expanded technique aids in evaluating the differences between satellite sensors. Therefore, this technique was validated with several trusted cross-calibration techniques to evaluate its accuracy. Initially, the expanded T2T technique was validated with three independent RadCaTS RRV, DIMITRI-PICS, and APICS models, and results show a 1% average difference with other models over all bands. Further, this technique was validated with other SDSU techniques to calibrate the newly launched satellite Landsat 9 with 8, demonstrating good agreement in all bands within 0.5%. This technique was also validated for Terra MODIS and ETM+, showing consistency within 1% for all bands compared to four PICS sites. Additionally, the T2T technique was applied to a global scale using EPICS Global sites. The expanded T2T cross-calibration gain result obtained for Landsat 8 versus Landsat 7/8, Sentinel 2A/2B, and Terra/Aqua MODIS presented that the difference between these pairs was within 0.5–1% for most of the spectral bands. Total uncertainty obtained for these pairs of sensors using Monte Carlo Simulation varies from 2.5–4% for all bands except for SWIR2 bands, which vary up to 5%. The difference between EPICS Global and EPICS North Africa was calculated using the ratio of trend gain; the difference among them was within 0.5–1% difference on average for all the sensors and bands within a 0.5% uncertainty level difference.