Ratilal Akabari

Mr. Ratilal Akabari

SUNY Upstate Medical University, Syracuse, Indiana, USA
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Genes
Verified
Journal Article
Open access
PDF file
RARatilal Akabari
Ratilal Akabari
DQDahui Qin
Dahui Qin
MHMohammad Omar Hussaini
Mohammad Omar Hussaini
Background: The detection of CEBPA and FLT3 mutations by next generation sequencing (NGS) is challenging due to high GC content and Internal Tandem Duplications (ITDs). Recent advances have been made to surmount these challenges. In this study, we compare three commercial kits and evaluate the performance of these more advanced hybrid-capture and AMP-chemistry based methods. Methods: Amplicon-based TSM 54-Gene Panel (Illumina) was evaluated against hybridization-capture SOPHiA Genetics MSP, OGT SureSeq, and AMP chemistry-based VariantPlex (Archer) for wet-lab workflow and data-analysis pipelines. Standard kit directions and commercial analysis pipelines were followed. Seven CEBPA and 10 FLT3-positive cases were identified that previously were missed on an amplicon NGS assay. The average reads, coverage uniformity, and the detection of CEBPA or FLT3 mutations were compared. Results: All three panels detected all 10 CEBPA mutations and all 10 FLT3 ITDs with 100% sensitivity. In addition, there was high concordance (100%) between all three panels detecting 47/47 confirmed variants in a set of core myeloid genes. Conclusions: The results show that the NGS assays are now able to reliably detect CEBPA mutations and FLT3 ITDs. These assays may allow foregoing additional orthogonal testing for CEBPA and FLT3.

Verified
Journal Article
Open access
PDF file
DQDahui Qin
Dahui Qin
MFMark Forster
Mark Forster
SGShital M. Gandhi
Shital M. Gandhi
RARatilal Akabari
Ratilal Akabari
ZZZhong Zheng
Zhong Zheng
KLKatherine Lovinger
Katherine Lovinger
Sample identification error is a severe medical error in clinical molecular diagnostic laboratories, which can lead to reporting the wrong results for the patient involved. Sample contamination can also lead to incorrect test reports. Avoiding sample identification error and sample contamination could be life-saving. Sample switch and sample contamination could happen on laboratory bench works, especially when pipetting into multi-well plates. It is difficult to realize such errors during laboratory bench work. Laboratory staff may not be aware of such an error when it happens. DNA fingerprinting technology can be used to determine sample identity and subsequently identify sample switch and sample contamination in the laboratory. Our laboratory has explored the usage of this technology in our quality control process and successfully established that DNA fingerprinting can be used to monitor sample switch and sample contamination in next-generation sequencing and BCR/ABL1 real-time PCR bench work.