Rhonda R Franklin

Prof. Rhonda R Franklin

University of Minnesota, Minneapolis, Minnesota, USA
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ZNZohreh Nemati
Zohreh Nemati
MKMohammad Reza Zamani Kouhpanji
Mohammad Reza Zamani Kouhpanji
FZFang Zhou
Fang Zhou
Raja DasRaja Das
Raja Das
KMKelly Makielski
Kelly Makielski
JMJavier Alonso Masa
Javier Alonso Masa
Isolating and analyzing tumor-derived exosomes (TEX) can provide important information about the state of a tumor, facilitating early diagnosis and prognosis. Since current isolation methods are mostly laborious and expensive, we propose herein a fast and cost-effective method based on a magnetic nanoplatform to isolate TEX. In this work, we have tested our method using three magnetic nanostructures: (i) Ni magnetic nanowires (MNWs) (1500 × 40 nm), (ii) Fe3O4 nanorods (NRs) (41 × 7 nm), and (iii) Fe3O4 cube-octahedral magnetosomes (MGs) (45 nm) obtained from magnetotactic bacteria. The magnetic response of these nanostructures has been characterized, and we have followed their internalization inside canine osteosarcoma OSCA-8 cells. An overall depiction has been obtained using a combination of Fluorescence and Scanning Electron Microscopies. In addition, Transmission Electron Microscopy images have shown that the nanostructures, with different signs of degradation, ended up being incorporated in endosomal compartments inside the cells. Small intra-endosomal vesicles that could be precursors for TEX have also been identified. Finally, TEX have been isolated using our magnetic isolation method and analyzed with a Nanoparticle tracking analyzer (NanoSight). We observed that the amount and purity of TEX isolated magnetically with MNWs was higher than with NRs and MGs, and they were close to the results obtained using conventional non-magnetic isolation methods.

21 December 2018 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
WZWen Zhou
Wen Zhou
JUJoseph Um
Joseph Um
YZYali Zhang
Yali Zhang
ANAlexander P. Nelson
Alexander P. Nelson
ZNZohreh Nemati
Zohreh Nemati
RFRhonda R Franklin
Rhonda R Franklin
This paper presents the development of a biolabeling system using different ferromagnetic nanowire types. The proposed biolabeling system concept includes a cell separation procedure description using magnetic nanowires and how nanowires can be used and identified as biolabels. A study on single magnetic nanowire behavior is performed, and the algorithm used to characterize and identify each nanowire type separately and from a mix of multiple types is described. The algorithm is verified using measurement data from individual nanowire array samples and stacked combinations of cobalt, iron and nickel. From the strong correlation between the measured transmission coefficient data of magnetic nanowire arrays and a mathematical model, the potential of interpreting multiple magnetic nanowire types inside cells is confirmed.

4 December 2012
Verified
Book Chapter
Closed access
MEMichael Etheridge
Michael Etheridge
NMNavid Manuchehrabadi
Navid Manuchehrabadi
RFRhonda R Franklin
Rhonda R Franklin
JBJohn Bischof
John Bischof

5 October 2020 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
YZYali Zhang
Yali Zhang
JUJoseph Um
Joseph Um
BSBethanie Stadler
Bethanie Stadler
RFRhonda R Franklin
Rhonda R Franklin
In this letter, a straightforward accurate method for magnetic nanowires (MNWs) ferromagnetic resonance (FMR) frequency determination and permeability extraction is proposed. FMR frequencies are obtained using a one-port coplanar waveguide (CPW) circuit system. Relative permeability, defined as μ =μ '-jμ '', of MNW samples is extracted by ``four steps'' method, commonly used for thin films (Bekker et al., 2004; Liu et al., 2005; Wei et al., 2015). MNW samples with and without copper (Cu) layer are compared. Samples with a Cu layer show stronger FMR resonances, negligible influences from board resonances, and low distortion μ' compared to those without a Cu layer. From μ'', the average linewidth of a cobalt sample with and without Cu layer is 4.96 and 5.6 GHz, respectively. From the peak of μ'', the FMR frequency of an iron sample is higher at low dc field when compared to cobalt. This can be beneficial for microwave device design when external dc field is limited, and higher operating frequency is required.

6 February 2025 in IEEE Microwave Magazine
Verified
Journal Article
Closed access
YZYali Zhang
Yali Zhang
ADAditya Dave
Aditya Dave
NMNikita Majabeen
Nikita Majabeen
RHRashaunda Henderson
Rashaunda Henderson
BSBethanie Stadler
Bethanie Stadler
RFRhonda R Franklin
Rhonda R Franklin
Recently, advancing RF interconnect technologies for future 2.5D and 3D integration have been identified as an important game changer for energy efficient complex integrated circuit systems. Researchers are improving the performance of traditional interconnect technologies, such as wire bonds, and are exploring novel technologies as alternative interconnect solutions, such as stich chip and copper nanowire vias. Due to the high speed needs of 5G and 6G communication, interconnect operation needs to extend into the millimeter and sub-millimeter wave frequency range, which poses big challenges for designs with low loss and broad bandwidth. Herein, this review discusses and describes recent advances in interconnect technologies for wired and wireless RF applications. The research work is promising and shows a variety of methods to achieve low loss over a broad range of frequencies needed to truly enable design of energy efficient complex integrated circuit systems.

1 March 2022 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
LGLinsey Griffin
Linsey Griffin
MYMinji Yu
Minji Yu
ACAlison Cloet
Alison Cloet
SASusan Arnold
Susan Arnold
NCNeil Carlson
Neil Carlson
WDWilliam Durfee
William Durfee
At the beginning of the COVID-19 pandemic when traditional N95 respirators were in short supply in the United States, there was a need for alternative products that did not rely on traditional avenues of sourcing and manufacturing. The purpose of this research was to develop and test alternatives to N95 respirators that could be produced locally without specialized materials and processes. Through an interdisciplinary team of experts, new mask designs that use repurposed filtration media and commercially available components were developed and tested for filtration and fit against current N95 standards. Filtration efficiency test results showed that the filtration media can be used for high-quality facemasks and quantitative fit testing demonstrated that the new mask designs could be viable alternatives to traditional N95 facemasks when those masks are in short supply. Manufacturing viability was tested utilizing a workforce to create 6000 masks over 10 days. The ability to quickly produce masks at scale using a workforce without specialized skills demonstrated the feasibility of the mask designs and manufacturing approach to address shortages of critical healthcare equipment, mitigate risk for healthcare and essential workers, and minimize the transmission and spread of disease.