RICARDO RODRIGUEZ JORGE

Dr. RICARDO RODRIGUEZ JORGE

Information and communications technologies, CEIT-Basque Research and Technology Alliance, San Sebastian, Spain
orcid
Research Scientist / Data Scientist

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Journal of Applied Research and Technology
Verified
Journal Article
Open access
RICARDO RODRIGUEZ JORGERICARDO RODRIGUEZ JORGE
RICARDO RODRIGUEZ JORGE
AMA. Mexicano
A. Mexicano
JBJ. Bila
J. Bila
SCS. Cervantes
S. Cervantes
RPR. Ponce
R. Ponce
This paper presents a novel approach for QRS complex detection and extraction of electrocardiogram signals for different types of arrhythmias. Firstly, the ECG signal is filtered by a band pass filter, and then it is differentiated. After that, the Hilbert transform and the adaptive threshold technique are applied for QRS detection. Finally, the Principal Component Analysis is implemented to extract features from the ECG signal. Nineteen different records from the MIT-BIH arrhythmia database have been used to test the proposed method. A 96.28% of sensitivity and a 99.71% of positive predictivity are reported in this testing for QRS complexity detection, being a positive result in comparison with recent researches

1 June 2021 in Internet of Things
Verified
Journal Article
Closed access
RICARDO RODRIGUEZ JORGERICARDO RODRIGUEZ JORGE
RICARDO RODRIGUEZ JORGE
ILI. De León-Damas
I. De León-Damas
JBJiri Bila
Jiri Bila
JŠJiří Škvor
Jiří Škvor

1 July 2010
Verified
Conference Paper
Closed access
IBIvo Bukovsky
Ivo Bukovsky
NHNoriyasu Homma
Noriyasu Homma
LSLadislav Smetana
Ladislav Smetana
RICARDO RODRIGUEZ JORGERICARDO RODRIGUEZ JORGE
RICARDO RODRIGUEZ JORGE
MMMartina Mironovova
Martina Mironovova
SVStanislav Vrana
Stanislav Vrana
The paper discusses the quadratic neural unit (QNU) and highlights its attractiveness for industrial applications such as for plant modeling, control, and time series prediction. Linear systems are still often preferred in industrial control applications for their solvable and single solution nature and for the clarity to the most application engineers. Artificial neural networks are powerful cognitive nonlinear tools, but their nonlinear strength is naturally repaid with the local minima problem, overfitting, and high demands for application-correct neural architecture and optimization technique that often require skilled users. The QNU is the important midpoint between linear systems and highly nonlinear neural networks because the QNU is relatively very strong in nonlinear approximation; however, its optimization and performance have fast and convex-like nature, and its mathematical structure and the derivation of the learning rules is very comprehensible and efficient for implementation.

1 August 2014
Verified
Conference Paper
Closed access
RICARDO RODRIGUEZ JORGERICARDO RODRIGUEZ JORGE
RICARDO RODRIGUEZ JORGE
JBJiri Bila
Jiri Bila
AMAdriana Mexicano
Adriana Mexicano
SCSalvador Cervantes
Salvador Cervantes
RPRafael Ponce
Rafael Ponce
NNN. B. Nghien
N. B. Nghien
This paper presents a predictive model for the prediction and modeling of nonlinear, chaotic, and non-stationary electrocardiogram signals. The model is based on the combined usage of Hilbert-Huang transform, False nearest neighbors, and a novel neural network architecture. This model is intended to increase the prediction accuracy by applying the Empirical Mode Decomposition over a signal, and to reconstruct the signal by adding each calculated Intrinsic Mode Function and its residue. The Intrinsic Mode Function that obtains the highest frequency oscillation is not considered during the reconstruction. The optimal embedding dimension space of the reconstructed signal is obtained by False Nearest Neighbors algorithm. Finally, for the prediction horizon, a neural network retraining technique is applied to the reconstructed signal. The method has been validated using the record 103 from MIT-BIH arrhythmia database. Results are very promising since the measured root mean squared errors are 0.031, 0.05, and 0.085 of the ECG amplitude, for the prediction horizons of 0.0028, 0.0056, 0.0083 seconds, respectively.

1 January 2016 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
AMA. Mexicano
A. Mexicano
RICARDO RODRIGUEZ JORGERICARDO RODRIGUEZ JORGE
RICARDO RODRIGUEZ JORGE
SCS. Cervantes
S. Cervantes
Pascual Noradino Montes DorantesPascual Noradino Montes Dorantes
Pascual Noradino Montes Dorantes
MJM. Jiménez
M. Jiménez
AAA. Abrego
A. Abrego
In this paper, an enhanced version of the K-Means algorithm that incorporates a new convergence criterion is presented. The largest centroid displacement at each iteration was used as mean to define whether the algorithm stops or not its execution. Computational experiments showed that in general, the Early Stop Heuristic is able to reduce the execution time of the standard version without a significant quality reduction. According to the experimentation, the Early Stop Heuristic reached a time reduction up to 87.06% only a quality reduction of 2.46% for the Transactions dataset, the worst case occurred when the Skin instance was grouped into 200 clusters obtaining a 79.04% in reduction time, and a 4.27% in quality reduction.

3 November 2017
Verified
Book Chapter
Closed access
PDF file
RICARDO RODRIGUEZ JORGERICARDO RODRIGUEZ JORGE
RICARDO RODRIGUEZ JORGE
EGEdgar Martínez García
Edgar Martínez García
RCRafael Torres Córdoba
Rafael Torres Córdoba
JBJiri Bila
Jiri Bila
JMJ. Mizera-Pietraszko
J. Mizera-Pietraszko