Rifai Chai

Dr. Rifai Chai

Swinburne University of Technology, Melbourne, Victoria, Australia
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2020 in Psychophysiology
Verified
Journal Article
Closed access
PDF file
Yvonne TranYvonne Tran
Yvonne Tran
ACAshley Craig
Ashley Craig
RCRachel Craig
Rachel Craig
Rifai ChaiRifai Chai
Rifai Chai
HNHung Nguyen
Hung Nguyen

12 June 2019 in The Journal of Psychology
Verified
Journal Article
Closed access
MSMitchell R. Smith
Mitchell R. Smith
Rifai ChaiRifai Chai
Rifai Chai
HNHung Nguyen
Hung Nguyen
SMSamuele M. Marcora
Samuele M. Marcora
ACAaron Coutts
Aaron Coutts
This investigation assessed the impact of three cognitively demanding tasks on cognitive performance, subjective, and physiological indicators of mental fatigue. Following familiarization, participants completed four testing sessions, separated by 48 h. During each session, participants watched a 45-min emotionally neutral documentary (control) or completed one of the following computer tasks: Psychomotor Vigilance Task (PVT); AX-Continuous Performance Test (AX-CPT); or Stroop Task. Mental fatigue was assessed before and at regular periods for 60 min following the 45-min treatments. Cognitive performance was assessed using 3-min PVT, and task performance. Subjective assessments were conducted using the Brunel Mood Scale, and visual analog scales (VAS). Physiological indicators of mental fatigue included electroencephalography (EEG), and heart rate variability (HRV). Subjective ratings of mental fatigue increased from pre to 0-min post in all-treatments, but not the documentary (p < 0.05). Subjective fatigue (VAS) remained higher (p < 0.05) than pretreatment values for 20-, 50-, and 60-min following the PVT, Stroop, and AX-CPT respectively. The cognitively demanding tasks had unclear effects on 3-min PVT, EEG, and HRV assessments. Tasks requiring response inhibition appear to induce fatigue for longer durations than a simple vigilance task. Simple VAS appear to be the most practical method for assessing mental fatigue.

19 February 2016 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Rifai ChaiRifai Chai
Rifai Chai
Ganesh R NaikGanesh R Naik
Ganesh R Naik
TNTuan Nghia Nguyen
Tuan Nghia Nguyen
SLSai Ho Ling
Sai Ho Ling
Yvonne TranYvonne Tran
Yvonne Tran
HNHung Nguyen
Hung Nguyen
This paper presents a two-class electroencephal-ography-based classification for classifying of driver fatigue (fatigue state versus alert state) from 43 healthy participants. The system uses independent component by entropy rate bound minimization analysis (ERBM-ICA) for the source separation, autoregressive (AR) modeling for the features extraction, and Bayesian neural network for the classification algorithm. The classification results demonstrate a sensitivity of 89.7%, a specificity of 86.8%, and an accuracy of 88.2%. The combination of ERBM-ICA (source separator), AR (feature extractor), and Bayesian neural network (classifier) provides the best outcome with a p-value <; 0.05 with the highest value of area under the receiver operating curve (AUC-ROC = 0.93) against other methods such as power spectral density as feature extractor (AUC-ROC = 0.81). The results of this study suggest the method could be utilized effectively for a countermeasure device for driver fatigue identification and other adverse event applications.

7 March 2017 in Frontiers in Neuroscience
Verified
Journal Article
Open access
Rifai ChaiRifai Chai
Rifai Chai
SLSai Ho Ling
Sai Ho Ling
PSPhyo Phyo San
Phyo Phyo San
Ganesh R NaikGanesh R Naik
Ganesh R Naik
TNTuan N. Nguyen
Tuan N. Nguyen
HNHung Nguyen
Hung Nguyen
This paper presents an improvement of classification performance for electroencephalography (EEG)-based driver fatigue classification between fatigue and alert states with the data collected from 43 participants. The system employs autoregressive (AR) modeling as the features extraction algorithm, and sparse-deep belief networks (sparse-DBN) as the classification algorithm. Compared to other classifiers, sparse-DBN is a semi supervised learning method which combines unsupervised learning for modeling features in the pre-training layer and supervised learning for classification in the following layer. The sparsity in sparse-DBN is achieved with a regularization term that penalizes a deviation of the expected activation of hidden units from a fixed low-level prevents the network from overfitting and is able to learn low-level structures as well as high-level structures. For comparison, the artificial neural networks (ANN), Bayesian neural networks (BNN) and original deep belief networks (DBN) classifiers are used. The classification results show that using AR feature extractor and DBN classifiers, the classification performance achieves an improved classification performance with a of sensitivity of 90.8%, a specificity of 90.4%, an accuracy of 90.6% and an area under the receiver operating curve (AUROC) of 0.94 compared to ANN (sensitivity at 80.8%, specificity at 77.8%, accuracy at 79.3% with AUC-ROC of 0.83) and BNN classifiers (sensitivity at 84.3%, specificity at 83%, accuracy at 83.6% with AUROC of 0.87). Using the sparse-DBN classifier, the classification performance improved further with sensitivity of 93.9%, a specificity of 92.3% and an accuracy of 93.1% with AUROC of 0.96. Overall, the sparse-DBN classifier improved accuracy by 13.8%, 9.5% and 2.5% over ANN, BNN and DBN classifiers respectively.

1 August 2015
Verified
Conference Paper
Closed access
HCHenry Candra
Henry Candra
MYMitchell Yuwono
Mitchell Yuwono
Rifai ChaiRifai Chai
Rifai Chai
AHArdi Handojoseno
Ardi Handojoseno
IEIrraivan Elamvazuthi
Irraivan Elamvazuthi
Steven SuSteven Su
Steven Su
When dealing with patients with psychological or emotional symptoms, medical practitioners are often faced with the problem of objectively recognizing their patients' emotional state. In this paper, we approach this problem using a computer program that automatically extracts emotions from EEG signals. We extend the finding of Koelstra et. al [IEEE trans. affective comput., vol. 3, no. 1, pp. 18-31, 2012] using the same dataset (i.e. the DEAP: dataset for emotion analysis using electroencephalogram, physiological and video signals), where we observed that the accuracy can be further improved using wavelet features extracted from shorter time segments. More precisely, we achieved accuracy of 65% for both valence and arousal using the wavelet entropy of 3 to 12 seconds signal segments. This improvement in accuracy entails an important discovery that information on emotions contained in the EEG signal may be better described in term of wavelets and in shorter time segments.

12 December 2013 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Rifai ChaiRifai Chai
Rifai Chai
SLSai Ho Ling
Sai Ho Ling
GHGregory P. Hunter
Gregory P. Hunter
Yvonne TranYvonne Tran
Yvonne Tran
HNHung Nguyen
Hung Nguyen
This paper presents the classification of a three-class mental task-based brain-computer interface (BCI) that uses the Hilbert-Huang transform for the features extractor and fuzzy particle swarm optimization with cross-mutated-based artificial neural network (FPSOCM-ANN) for the classifier. The experiments were conducted on five able-bodied subjects and five patients with tetraplegia using electroencephalography signals from six channels, and different time-windows of data were examined to find the highest accuracy. For practical purposes, the best two channel combinations were chosen and presented. The three relevant mental tasks used for the BCI were letter composing, arithmetic, and Rubik's cube rolling forward, and these are associated with three wheelchair commands: left, right, and forward, respectively. An additional eyes closed task was collected for testing and used for on-off commands. The results show a dominant alpha wave during eyes closure with average classification accuracy above 90%. The accuracies for patients with tetraplegia were lower compared to the able-bodied subjects; however, this was improved by increasing the duration of the time-windows. The FPSOCM-ANN provides improved accuracies compared to genetic algorithm-based artificial neural network (GA-ANN) for three mental tasks-based BCI classifications with the best classification accuracy achieved for a 7-s time-window: 84.4% (FPSOCM-ANN) compared to 77.4% (GA-ANN). More comparisons on feature extractors and classifiers were included. For two-channel classification, the best two channels were O1 and C4, followed by second best at P3 and O2, and third best at C3 and O2. Mental arithmetic was the most correctly classified task, followed by mental Rubik's cube rolling forward and mental letter composing.