Robert Rink

Dr. Robert Rink

Institute of Power Engineering Research Institute, Warsaw, Mazowieckie, Poland
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
MKMichal Kosmecki
Michal Kosmecki
Robert RinkRobert Rink
Robert Rink
AWAnna Wakszyńska
Anna Wakszyńska
RCRoberto Ciavarella
Roberto Ciavarella
Marialaura Di SommaMarialaura Di Somma
Marialaura Di Somma
Giorgio GraditiGiorgio Graditi
Giorgio Graditi
Along with the increasing share of non-synchronous power sources, the inertia of power systems is being reduced, which can give rise to frequency containment problems should an outage of a generator or a power infeed happen. Low system inertia is eventually unavoidable, thus power system operators need to be prepared for this condition. This paper addresses the problem of low inertia in the power system from two different perspectives. At a system level, it proposes an operation planning methodology, which utilises a combination of power flow and dynamic simulation for calculation of existing inertia and, if need be, synthetic inertia (SI) to fulfil the security criterion of adequate rate of change of frequency (RoCoF). On a device level, it introduces a new concept for active power controller, which can be applied virtually to any power source with sufficient response time to create synthetic inertia. The methodology is demonstrated for a 24 h planning period, for which it proves to be effective. The performance of SI controller activated in a battery energy storage system (BESS) is positively validated using a real-time digital simulator (RTDS). Both proposals can effectively contribute to facilitating the operation of low inertia power systems.

27 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
BGBartlomiej Gawin
Bartlomiej Gawin
Robert MalkowskiRobert Malkowski
Robert Malkowski
Robert RinkRobert Rink
Robert Rink
The estimation of electric power utilization, its baseload, and its heating, light, ventilation, and air-conditioning (HVAC) power component, which represents a very large portion of electricity usage in commercial facilities, are important for energy consumption controls and planning. Non-intrusive load monitoring (NILM) is the analytical method used to monitor the energy and disaggregate total electrical usage into appliance-related signals as an alternative to installing multiple electricity meters in the building. However, despite considerable progress, there are a limited number of tools dedicated to the problem of reliable and complete energy disaggregation. This paper presents an experiment consisting in designing an electrical system with electrical energy receivers, and then starting NILM disaggregation using machine learning algorithms (MLA). The quality of this disaggregation was assessed using dedicated indicators. Subsequently, the quality of these MLA was also verified using the available BLUED data source. The results show that the proposed method guarantees non-intrusive load disaggregation but still requires further research and testing. Measurement data have been published as open research data and listed in the literature section repository.

9 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
Robert RinkRobert Rink
Robert Rink
Robert MalkowskiRobert Malkowski
Robert Malkowski
BGBartlomiej Gawin
Bartlomiej Gawin
KJKlara Janiga
Klara Janiga
This paper presents the design of an innovative scalable wind turbine emulator. The system’s hardware and software components are described in detail including test results, demonstrating the research potential of the proposed design. The uniqueness of the proposed solution lies in its scalability, achieved despite the use of physical devices with fixed parameters. This scalability allows for the flexible shaping of the system’s structure and parameters, allowing it to emulate both individual wind turbines with a capacity ranging from kilowatts to megawatts as well as aggregated models of entire wind farms. The emulator was developed using the hardware-in-the loop (HIL) concept and consists of a digital part including aerodynamic and mechanical models (wind, rotor, shaft models, disturbances, etc.) and control systems for mechanical and electrical devices within the wind turbine. The digital component has a modular structure, which allows for the replacement of any module of the native control system with the user’s custom designed one and testing its properties over a broad range of parameters. The test results presented in the article demonstrate a satisfactory level of accuracy of the developed emulator.

1 December 1993 in Energy Conversion and Management
Verified
Journal Article
Closed access
Robert RinkRobert Rink
Robert Rink
MZMOHAMMED ZAHEERUDDIN
MOHAMMED ZAHEERUDDIN

1 November 2018
Verified
Conference Paper
Closed access
MKMichal Kosmecki
Michal Kosmecki
Robert RinkRobert Rink
Robert Rink
A new method for on-line grid impedance estimation is presented in the paper. It is based on an algorithm that requires no measurements from other buses. What is more, in normal operation it does not need to inject any current to the grid at the point of common coupling as it common in active methods for impedance estimation. The paper includes a mathematical derivation of the key equations, simulation results for a simple test system as well as performance evaluation. Laboratory tests are ongoing.

1 March 2014 in Acta Energetica
Verified
Journal Article
Closed access
BSBogdan Sobczak
Bogdan Sobczak
Robert RinkRobert Rink
Robert Rink
RKRafał Kuczyński
Rafał Kuczyński
RTRobert Trębski
Robert Trębski