Roger Lecomte

Prof. Roger Lecomte

orcid

Research Focus & Metrics

Academic Career Length

51Years (1976-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2015 in The FASEB Journal
Verified
Journal Article
Open access
PDF file
SLSébastien M. Labbé
Sébastien M. Labbé
ACAlexandre Caron
Alexandre Caron
IBInan Bakan
Inan Bakan
MLMathieu Laplante
Mathieu Laplante
ACAndré C. Carpentier
André C. Carpentier
DRDenis Richard
Denis Richard
The present study was designed to investigate the effects of cold on brown adipose tissue (BAT) energy substrate utilization in vivo using the positron emission tomography tracers [ 18 F]fluorodeoxyglucose (glucose uptake), 14(R,S)‐[ 18 F]fluoro‐6‐thiaheptadecanoic acid [nonesterified fatty acid (NEFA) uptake], and [ 11 C]acetate (oxidative activity). The measurements were performed in rats adapted to 27°C, which were acutely subjected to cold (10°C) for 2 and 6 hours, and in rats chronically adapted to 10°C for 21 days, which were returned to 27°C for 2 and 6 hours. Cold exposure (acutely and chronically) led to increases in BAT oxidative activity, which was accompanied by concomitant increases in glucose and NEFA uptake. The increases were particularly high in cold‐adapted rats and largely readily reduced by the return to a warm environment. The cold‐induced increase in oxidative activity was meaningfully blunted by nicotinic acid, a lipolysis inhibitor, which emphasizes in vivo the key role of intracellular lipid in BAT thermogenesis. The changes in BAT oxidative activity and glucose and NEFA uptakes were paralleled by inductions of genes involved in not only oxidative metabolism but also in energy substrate replenishment (triglyceride and glycogen synthesis). The capacity of BAT for energy substrate replenishment is remarkable.—Labbé, S. M., Caron, A., Bakan, I., Laplante, M., Carpentier, A. C., Lecomte, R., Richard, D. In vivo measurement of energy substrate contribution to cold‐induced brown adipose tissue thermogenesis. FASEB J. 29, 2046‐2058 (2015). www.fasebj.org

14 June 2012 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
AGAndrew L. Goertzen
Andrew L. Goertzen
QBQinan Bao
Qinan Bao
MBMélanie Bergeron
Mélanie Bergeron
EBEric Blankemeyer
Eric Blankemeyer
SBStephan Blinder
Stephan Blinder
RLRichard Laforest
Richard Laforest
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. Methods: We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: microPET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. Results: The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Conclusion: Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand.

12 July 2004 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CPC.M. Pepin
C.M. Pepin
PBP. Berard
P. Berard
APA.-L. Perrot
A.-L. Perrot
CPC. Pepin
C. Pepin
DHD. Houde
D. Houde
HDH. Dautet
H. Dautet
The luminescence and nuclear spectroscopic properties of the new cerium-doped rare-earth scintillator lutetium-yttrium oxyorthosilicate (Lu/sub 0.6/Y/sub 1.4/Si/sub 0.5/:Ce, LYSO) were investigated and compared to those of both recent and older LSO crystals. UV-excited luminescent spectra outline important similarities between LYSO and LSO scintillators. The two distinct Ce1 and Ce2 luminescence mechanisms previously identified in LSO are also present in LYSO scintillators. The energy and timing resolutions were measured using avalanche photodiode (APD) and photomultiplier tube (PMT) readouts. The dependence of energy resolution on gamma-ray energy was also assessed to unveil the crystal intrinsic resolution parameters. In spite of significant progress in light output and luminescence properties, the energy resolution of these scintillators appears to still suffer from an excess variance in the number of scintillation photons. Pulse-shape discrimination between LYSO and LSO scintillators has been successfully achieved in phoswich assemblies, confirming LYSO, with a sufficient amount of yttrium to modify the decay time, to be a potential candidate for depth-of-interaction determination in multicrystal PET detectors.

10 February 2009 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MBMélanie Bergeron
Mélanie Bergeron
JCJules Cadorette
Jules Cadorette
JBJean-François Beaudoin
Jean-François Beaudoin
MLMartin D. Lepage
Martin D. Lepage
GRGhislain Robert
Ghislain Robert
RLRoger Lecomte
Roger Lecomte
The LabPETtrade is a fully digital avalanche photodiode (APD) based PET scanner designed for state-of-the-art molecular and genomic imaging of small animals. Two versions of the scanner were evaluated, having 3.75 (LabPET4) and 7.5 cm axial FOV (LabPET8). The detectors are made of 2times2times12/14 mm3 LYSO and LGSO crystals assembled in phoswich pairs read out by an APD. After digital crystal identification, the average energy resolution is 24plusmn6% for LYSO and 25plusmn6% for LGSO. The scanner's overall timing resolution is 6.6 ns for LYSO/LYSO and 10.7 ns for LGSO/LGSO coincidences after coarse timing alignment. The FBP reconstructed tangential/radial resolution is 1.3/1.4 mm FWHM (2.5/2.4 mm FWTM) at the FOV center and remains below 2.1 mm FWHM (3.6 mm FWTM) within the central 4-cm diameter FOV. MLEM reconstruction of a micro resolution phantom provided clear separation of the 1.0 mm spots. With an energy window of 250-650 keV, the sensitivity is 1.1% for LabPET4 and 2.1% for LabPET8. The imaging capabilities of the scanner are demonstrated with in vivo images of rats and mice.

24 December 2008 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
RLRoger Lecomte
Roger Lecomte

11 May 2012 in Journal of Nuclear Medicine Technology
Verified
Journal Article
Open access
PDF file
RYRutao Yao
Rutao Yao
RLRoger Lecomte
Roger Lecomte
ECElpida S. Crawford
Elpida S. Crawford
Small-animal PET refers to imaging of animals such as rats and mice using dedicated PET scanners. Small-animal PET has been used extensively in modern biomedical research. It provides a quantitative measure of the 3-dimensional distribution of a radiopharmaceutical administered to a live subject noninvasively. In this article, we will discuss the operational and technical aspects of small-animal PET; make some comparisons between small-animal PET and human PET systems; identify the challenges of, opportunities for, and ultimate limitations in applying small-animal PET; and discuss some representative small-animal PET applications. Education objectives: After reading this article, the technologist will be able to explain the requirements and benefits of small-animal PET in biomedical research, describe the design and general characteristics of a small-animal PET system, list and describe some of the challenges of imaging small animals, and discuss several small-animal PET applications.