Ruslan Kharak

Prof. Ruslan Kharak

Mechanical and Electrical Engineering, Poltava State Agrarian University, Poltava, Poltavs’ka Oblast’, Ukraine
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2019 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
OIOleg Ivanov
Oleg Ivanov
RKRuslan Kharak
Ruslan Kharak
Olena KostenkoOlena Kostenko
Olena Kostenko
VAVolodymyr Arendarenko
Volodymyr Arendarenko
ONOleksii Nazarenko
Oleksii Nazarenko
VSVictor Sarana
Victor Sarana
Estimation model of the diesel engine fuel system with an electromechanical device to intensify fuel supply

5 July 2024 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Verified
Journal Article
Open access
PDF file
Anatolii O SemenovAnatolii O Semenov
Anatolii O Semenov
RKRuslan Kharak
Ruslan Kharak
VAVolodymyr Arendarenko
Volodymyr Arendarenko
Yaroslav BychkovYaroslav Bychkov
Yaroslav Bychkov
A method for approximate estimation of load losses in distribution networks from 6 to 10 kV, as well as for lower voltage networks, has been proposed. The main advantage of this method is that the root mean square current is calculated only once for a series of calculations. This approach significantly reduces the time required for calculations and improves their accuracy, as it eliminates the need for multiple determinations of the root mean square current for each individual calculation. The proposed approach contributes to a better understanding of the influence of various factors on load losses, which allows for more effective planning and management of distribution networks. This is particularly important in the context of increasing loads on electrical networks and higher demands for their reliability and efficiency. In the calculation of electrical energy losses in distribution networks from 6 to 10 kV, methods that use generalized coefficients of electrical circuits and operating modes in the form of regression equations are widely applied. The most significant and independent factors, such as the input of active energy, total line length, number of line sections, total number of transformers, and their total installed capacity, must be taken into account and are included in the calculation equation. Additionally, the components used and their regular maintenance play an important role in electrical energy losses in electrical networks. The main direction of research is the optimization of distribution network parameters, taking into account the latest technologies and materials, as well as the implementation of automated monitoring and control systems that will allow timely detection and elimination of problems associated with electrical energy losses. The proposed method for estimating load losses in distribution networks is a promising direction for the development of the energy sector, which will contribute to improving the efficiency and reliability of electrical networks, as well as reducing the costs of their operation and maintenance.

30 September 2024 in Ukrainian Metrological Journal
Verified
Journal Article
Open access
PDF file
TSTamara Sakhno
Tamara Sakhno
VPValentyna Panchenko
Valentyna Panchenko
Anatolii O SemenovAnatolii O Semenov
Anatolii O Semenov
NBNikolay Barashkov
Nikolay Barashkov
RKRuslan Kharak
Ruslan Kharak
ЮСЮрій Сахно
Юрій Сахно
Ensuring homogeneity of the feed mixing is crucial for animal health and productivity. The growing complexity of feed formulations increases the need for uniform mixtures, particularly for young animals, where balanced feed significantly affects growth and consumption. Ferromagnetic microtracers, developed by MicroTracers Inc., are used to monitor mixing uniformity in dry feed production. These microtracers, including iron-based types, are effective due to their magnetic properties, facilitating detection, and separation. However, they are less suitable for liquid feeds, leading to the development of magnetic nanotracers based on the iron oxide for liquid feed applications. Nanoparticle Tracking Analysis (NTA) is used to measure the size and distribution of nanoparticles in liquid feeds, ensuring thus effective mixing. The stability and uniform distribution of magnetic nanoparticles are crucial, with various surfactants, such as dimethylamine salt of oleic acid (DMAOA) and ammonium oleate, influencing particle size and aggregation. DMAOA provides better dispersion and stability, essential for quality control in feed production. The concentration of cobalt in nanoparticles FexCoyOz was determined by a modified spectrophotometric method.

29 May 2026 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Verified
Journal Article
Open access
Anatolii O SemenovAnatolii O Semenov
Anatolii O Semenov
VAVolodymyr Arendarenko
Volodymyr Arendarenko
RKRuslan Kharak
Ruslan Kharak
VVViacheslav Vovk
Viacheslav Vovk
The article has a review and analytical character and is devoted to the systematization of modern approaches to the integration of vacuum circuit breakers with control, monitoring, and diagnostic systems in medium- and high-voltage electrical networks. The main attention is paid to 6–35 kV networks, where vacuum circuit breakers have gained the widest practical application, as well as to the prospects for their use in 110–220 kV high-voltage installations as part of Smart Grid digital substations. An analytical and comparative review of switching devices (oil, air, SF₆, and vacuum types) is presented, with a generalized analysis of the electrophysical mechanisms of arc extinction in vacuum, the influence of contact materials (CuCr, AgWC), and the degree of vacuum on the dielectric recovery of the contact gap. The architectures of monitoring and diagnostic systems compatible with IEC 61850 are evaluated, including sensors for electrical and thermal parameters, microprocessor controllers, and Supervisory Control and Data Acquisition or Automated Control System for Technological Processes integration. The results demonstrate that vacuum circuit breakers ensure fast arc extinction and rapid dielectric recovery, have a long switching life, and require no periodic maintenance. Integration with digital monitoring systems significantly reduces fault detection time and the number of emergency shutdowns, while increasing equipment availability. A structural scheme of an integrated “vacuum circuit breaker – control system” complex is proposed, along with practical recommendations for its implementation in industrial and agro-industrial networks of 6–35 kV and potentially up to 110–220 kV. The findings confirm the feasibility of transitioning to digital substations based on IEC 61850 standards. The practical implementation of the proposed technical solutions in industrial and agro-industrial electrical networks will ensure improved power supply reliability, enhanced energy efficiency, reduced operating costs, and compliance with the requirements of modern energy standards.

30 September 2024 in Avtoshliakhovyk Ukrayiny
Verified
Journal Article
Open access
PUPoltava State Agrarian University
Poltava State Agrarian University
OIOleg Ivanov
Oleg Ivanov
Oleksiy BurlakaOleksiy Burlaka
Oleksiy Burlaka
Anton KelemeshAnton Kelemesh
Anton Kelemesh
RKRuslan Kharak
Ruslan Kharak
The task of the research is to determine the static and dynamic characteristics of a tractor diesel when using a special hydraulic corrector in its fuel supply system. It is use to change the initial phase period of fuel injection into diesel cylinders for each fuel injection line. The developed hydraulic corrector is a body with a movable rod with an annular groove in the central part. The movement of the rod occurs with the help of a power electromagnet. The hydraulic correc-tor itself is a blocking element and blocks the fuel supply to the injector for a certain period. The duration of this period depends on the need to change the injection start time. Its installation does not require significant structural changes to the fuel system. Location – near the nozzle. To determine the efficiency of this hydraulic corrector, it is necessary to con-duct a complex of non-motorized and motorized studies. In the course of these studies, the advantage of using an experi-mental fuel supply system with a distribution fuel pump without a mechanical centrifugal clutch for advanced fuel injec-tion was determined. According to the results of comparative motorless studies, there is an improvement in the parame-ters of fuel supply in a wide range of changes in the frequency of rotation of the camshaft of the injection pump. There is a decrease in the fuel injection phase by 20…30%, an increase in the maximum injection pressure by 30…40 MPa, an in-crease in the average injection pressure by 10…20%. In addition, the use of this hydraulic corrector allows you to improve the quality of the transient acceleration mode of the 6ChN13/11.5 diesel engine by reducing the transition time to a new speed mode and improving the parameters of the air supply system. In particular, the duration of the stabilization of the rotation frequencies of the crankshaft and the rotor of the turbocompressor in the new stable mode of operation is reduced by an average of 10-12%, there is no clear read-justment of the operating parameters; a decrease in the normalization time of the turbocharger rotation frequency by 0.1s, a decrease in the temperature of the exhaust gases by 25°C and an increase in the boost pressure by 30% with an increase in the air supply to 540 m3/h were noted. The obtained results convincingly confirm the effectiveness and expe-diency of using the proposed hydraulic corrector for the modernization of the fuel systems of the auto-tractor diesel en-gine without significant structural changes in its fuel system. Keywords: hydraulic correction, fuel injection advance angle, electric control, crankshaft rotation frequency, turbo-charger, diesel, fuel supply parameters.

22 July 2019 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
AVAndrii Voitik
Andrii Voitik
VKVasyl Kravchenko
Vasyl Kravchenko
RORuslan Oliadnichuk
Ruslan Oliadnichuk
OPOlexandr Pushka
Olexandr Pushka
SKSerhii Kiurchev
Serhii Kiurchev
ONOleksii Nazarenko
Oleksii Nazarenko
Defining the parameters for a brush with polypropylene bristle when uncovering the root system of maternal plants