Soumya Kanti Manna

Dr. Soumya Kanti Manna

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2018 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Soumya Kanti MannaSoumya Kanti Manna
Soumya Kanti Manna
VDVenketesh N. Dubey
Venketesh N. Dubey
During the last two decades, a large variety of upper limb exoskeletons have been developed. Out of these, majority are platform based systems which might be the reason for not being widely adopted for post-stroke rehabilitation. Despite the potential benefits of platform-based exoskeletons as being rugged and reliable, stroke patients prefer to have a portable and user-friendly device that they can take home. However, the types of actuator as well as the actuation mechanism used in the exoskeleton are the inhibiting factors why portable exoskeletons are mostly non-existent for patient use. This paper presents a quantitative analysis of the actuation systems available for developing portable upper arm exoskeletons with their specifications. Finally, it has been concluded from this research that there are not many stand-alone arm exoskeletons which can provide all forms of rehabilitation, therefore, a generic solution has been proposed as the rehabilitation strategy to get best out of the portable arm exoskeletons.

4 April 2023 in Heliyon
Verified
Journal Article
Open access
Soumya Kanti MannaSoumya Kanti Manna
Soumya Kanti Manna
MAM.A. Hannan Bin Azhar
M.A. Hannan Bin Azhar
AGAnn Greace
Ann Greace
Neuromuscular diseases cause abnormal joint movements and drastically alter gait patterns in patients. The analysis of abnormal gait patterns can provide clinicians with an in-depth insight into implementing appropriate rehabilitation therapies. Wearable sensors are used to measure the gait patterns of neuromuscular patients due to their non-invasive and cost-efficient characteristics. FSR and IMU sensors are the most popular and efficient options. When assessing abnormal gait patterns, it is important to determine the optimal locations of FSRs and IMUs on the human body, along with their computational framework. The gait abnormalities of different types and the gait analysis systems based on IMUs and FSRs have therefore been investigated. After studying a variety of research articles, the optimal locations of the FSR and IMU sensors were determined by analysing the main pressure points under the feet and prime anatomical locations on the human body. A total of seven locations (the big toe, heel, first, third, and fifth metatarsals, as well as two close to the medial arch) can be used to measure gate cycles for normal and flat feet. It has been found that IMU sensors can be placed in four standard anatomical locations (the feet, shank, thigh, and pelvis). A section on computational analysis is included to illustrate how data from the FSR and IMU sensors are processed. Sensor data is typically sampled at 100 Hz, and wireless systems use a range of microcontrollers to capture and transmit the signals. The findings reported in this article are expected to help develop efficient and cost-effective gait analysis systems by using an optimal number of FSRs and IMUs.

12 December 2013 in Journal of Robotics
Verified
Journal Article
Open access
PDF file
Soumya Kanti MannaSoumya Kanti Manna
Soumya Kanti Manna
SBSubhasis Bhaumik
Subhasis Bhaumik
The developed exoskeleton device (Exorn) has ten degrees of freedom to control joints starting from shoulder griddle to wrist to provide better redundancy, portability, and flexibility to the human arm motion. A 3D conceptual model is being designed to make the system wearable by human arm. All the joints are simple revolute joints with desired motion limit. A Simulink model of the human arm is being developed with proper mass and length to determine proper torque required for actuating those joints. Forward kinematics of the whole system has been formulated for getting desired dexterous workspace. A proper and simple Graphical User Interface (GUI) and the required embedded system have been designed for providing physiotherapy lessons to the patients. In the literature review it has been found that researchers have generally ignored the motion of shoulder griddle. Here we have implemented those motions in our design. It has also been found that people have taken elbow pronation and supination motion as a part of shoulder internal and external rotation though both motions are quite different. A predefined resolved motion rate control structure with independent joint control is used so that all movements can be controlled in a predefined way.

8 October 2019 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
Soumya Kanti MannaSoumya Kanti Manna
Soumya Kanti Manna
VDVenketesh N. Dubey
Venketesh N. Dubey
Patients suffering from stroke need to undergo a standard and intensive rehabilitation therapy. The rehabilitation training consists of three sequential stages: the first stage is controlled joint movement under external actuator, the second stage deals with supporting the movements by providing assistive force, and the last stage provides variety and difficulty to exercises. Most of the exoskeletons developed so far for rehabilitation are restricted to a particular type of activity. Although a few exoskeletons incorporate different modes of rehabilitation, those are software controlled requiring sensory data acquisition and complex control architecture. To bridge this gap, a portable elbow exoskeleton has been developed for delivering three stages of rehabilitation in a single structure without affecting the range of motion and safety features. Use of electric motor and springs have been arranged in the actuation mechanism to minimize the energy consumption. The developed exoskeleton enhances torque to weight ratio compared to existing models, and all the three modes of rehabilitation have been controlled using a single motor.

2 May 2019 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
Soumya Kanti MannaSoumya Kanti Manna
Soumya Kanti Manna
VDVenketesh N. Dubey
Venketesh N. Dubey
Intensive and adaptive rehabilitation therapy is beneficial for post-stroke recovery. Three modes of rehabilitation are generally performed at different stages after stroke: external force-based control in the acute stage, assistive force-based rehabilitation in the midway of recovery and resistive force-based rehabilitation in the last stage. To achieve the above requirements, an innovative elbow exoskeleton has been developed to incorporate the three modes of rehabilitation in a single structure. The structure of the exoskeleton has been designed in such a way that the whole working region is divided into three where each region can provide a different mode of rehabilitation. Recovery rate can be varied for individuals since it depends on various parameters. To evaluate the rate of recovery, three joint parameters have been identified: range of angular movement, angular velocity and joint torque. These parameters are incorporated into the framework of planning a novel rehabilitation strategy, which is discussed in this article along with the structural description of the designed exoskeleton.

1 July 2017 in IEEE International Conference on Rehabilitation Robotics (ICORR)
Verified
Conference Paper
Closed access
Soumya Kanti MannaSoumya Kanti Manna
Soumya Kanti Manna
VDVenketesh N. Dubey
Venketesh N. Dubey
It is well proven that repetitive extensive training consisting of active and passive therapy is effective for patients suffering from neuromuscular deficits. The level of difficulty in rehabilitation should be increased with time to improve the neurological muscle functions. A portable elbow exoskeleton has been designed that will meet these requirements and potentially offers superior outcomes than human-assisted training. The proposed exoskeleton can provide both active and passive rehabilitation in a single structure without changing its configuration. The idea is to offer three levels of rehabilitation; namely active, passive and stiffness control in a single device using a single actuator. The mechanism also provides higher torque to weight ratio making it an energy efficient mechanism.