S M Shah Riyadh

Dr. S M Shah Riyadh

Department of Physics, Purdue University, Fort Wayne, Indiana, USA
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2021 in npj 2D Materials and Applications
Verified
Journal Article
Open access
PDF file
MRManthila Rajapakse
Manthila Rajapakse
BKBhupendra Karki
Bhupendra Karki
UAUsman O. Abu
Usman O. Abu
SPSahar Pishgar
Sahar Pishgar
RMRajib Khan Musa
Rajib Khan Musa
Jacek JasinskiJacek Jasinski
Jacek Jasinski
Recent advances in two-dimensional (2D) materials have led to the renewed interest in intercalation as a powerful fabrication and processing tool. Intercalation is an effective method of modifying the interlayer interactions, doping 2D materials, modifying their electronic structure or even converting them into starkly different new structures or phases. Herein, we discuss different methods of intercalation and provide a comprehensive review of various roles and applications of intercalation in next‐generation energy storage, optoelectronics, thermoelectrics, catalysis, etc. The recent progress in intercalation effects on crystal structure and structural phase transitions, including the emergence of quantum phases are also reviewed.

28 July 2020 in Nanotechnology
Verified
Journal Article
Open access
PDF file
BKBhupendra Karki
Bhupendra Karki
BFByron Freelon
Byron Freelon
MRManthila Rajapakse
Manthila Rajapakse
RMRajib Musa
Rajib Musa
S M Shah RiyadhS M Shah Riyadh
S M Shah Riyadh
Jacek JasinskiJacek Jasinski
Jacek Jasinski
We studied and compared the effect of tensile strain on the Raman spectra of black phosphorus (BP) and molybdenum ditelluride (MoTe2) crystals by using a simple custom strain device. In-situ Raman spectroscopy on BP revealed clear red shifting of all three phonon modes, A1 g, B2g and A2 g, under tensile stress. From our theoretical analyses, we found that such red shifting strongly depends on the direction of the strain exerted on the system even within the elastic deformation limit (i.e. strain ≤ 1 %). In particular, calculated results for the strain along the armchair direction are consistent with our experimental data, confirming that the strain applied to the sample acts effectively along the armchair direction. In a comparative study, we found that the effect of strain on the Raman shifting is larger for BP than that for MoTe2, presumably due to the smaller Young’s modulus of BP. We also see a remarkable resemblance between donor-type intercalation induced vibrational properties and tensile stress-induced vibrational properties in BP. We anticipate that our method of in-situ Raman spectroscopy can be an effective tool that can allow observation of strain effect directly which is critical for future flexible electronic devices.

10 March 2022 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
HTHamzeh Telfah
Hamzeh Telfah
KSKetan Sharma
Ketan Sharma
APAnam C. Paul
Anam C. Paul
S M Shah RiyadhS M Shah Riyadh
S M Shah Riyadh
TMTerry A. Miller
Terry A. Miller
JLJinjun Liu
Jinjun Liu
Vibronically resolved laser-induced fluorescence/dispersed fluorescence and cavity ring-down spectra of the electronic transition of the calcium isopropoxide [CaOCH(CH3)2] radical have been obtained and simulated.

21 May 2020 in Preprints.org
Verified
Preprint
Open access
MBMohammad Khairul Basher
Mohammad Khairul Basher
S M Shah RiyadhS M Shah Riyadh
S M Shah Riyadh
M. Khalid HossainM. Khalid Hossain
M. Khalid Hossain
MHMahmudul Hassan
Mahmudul Hassan
AAAbdur Rafiq Akand
Abdur Rafiq Akand
NDNarottam Das
Narottam Das
Zinc-oxide (ZnO) nanostructures including nanorods are currently considered as a pioneer research of interest world-wide due to their excellent application potentials in various applied fields especially for the improvement of energy harvesting photovoltaic solar cells (PSC). We report on the growth and morphological properties of zinc-oxide (ZnO) nanorods grown on the surface of plain zinc (non-etched and chemically etched) plates by using a simple, economical, and environment-friendly technique. We apply hot water treatment (HWT) technique to grow the ZnO nanorods and varies the process parameters, such as temperature and the process time duration. The morphological, and elemental analysis confirm the agglomeration of multiple ZnO nanorods with its proper stoichiometry. The obtained nanostructures for different temperatures with different time duration showed the variation in uniformity, density, thickness and nanonorods size. The ZnO nanorods produced on the etched zinc surface were found thicker and uniform as compared to those grown on the non-etched zinc surface. This chemically etched Zinc plates preparation can be an easy solution to grow ZnO nanorods with high density and uniformity suitable for PSC applications such as to enhance the energy conversion efficiency of the photovoltaic (PV) solar cells towards the future sustainable green earth.

9 September 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
DNDoe M Na
Doe M Na
JGJoel Guzman-Sanchez
Joel Guzman-Sanchez
JOJeremy Siboe Ogutu
Jeremy Siboe Ogutu
S M Shah RiyadhS M Shah Riyadh
S M Shah Riyadh
Recent advances have broadened the capabilities of continuous-wave cavity ring-down spectroscopy (CW-CRDS), driven by demands for higher sensitivity, faster acquisition, and reliable operation in non-ideal environments. This review organizes progress through a taxonomy spanning: (i) cavity and coupling architectures, including compact resonators, related fiber-based systems, extended spectral implementations, and multiplexed or comb-enabled designs; (ii) ring-down acquisition and modulation approaches, from controlled and random cavity-length tuning to coding-based and hybrid modulation–absorption schemes, with different trade-offs in spectral coverage and drift sensitivity; and (iii) analysis workflows that address precision and traceability, such as Allan-variance–guided optimization, saturation/nonlinearity modeling, and uncertainty reporting. We connect these technical choices to key application areas, including trace-gas sensing, reactive and transient media, particulate/aerosol measurements, breath analysis, and precision spectroscopy. Deployment considerations, including sampling interfaces, long-term stability, and calibration transfer, are discussed for harsh or space-limited settings. Remaining challenges in mode matching, baseline control, scalable multiplexing, and low-power integration are outlined to guide next-generation CW-CRDS instruments.

22 October 2026 in Spectroscopy Journal
Verified
Journal Article
Open access
PDF file
DNDoe M Na
Doe M Na
JGJoel Guzman-Sanchez
Joel Guzman-Sanchez
JOJeremy Siboe Ogutu
Jeremy Siboe Ogutu
S M Shah RiyadhS M Shah Riyadh
S M Shah Riyadh
Recent advances have broadened the capabilities of continuous-wave cavity ring-down spectroscopy (CW-CRDS), driven by demands for higher sensitivity, faster acquisition, and reliable operation in non-ideal environments. From the emergence of CW-CRDS in the late 1990s to developments reported through August 2026, this review traces changes in resonator architecture, resonance control, and acquisition strategies. Drawing on 171 cited sources, this narrative review organizes progress through a taxonomy spanning (i) cavity and coupling architectures, including compact resonators, related fiber-based systems, extended spectral implementations, and multiplexed or comb-enabled designs; (ii) ring-down acquisition and modulation approaches, ranging from controlled and random cavity-length tuning to coding-based and hybrid modulation–absorption schemes, with different trade-offs in spectral coverage and drift sensitivity; and (iii) analysis workflows that address precision and traceability, such as Allan-variance-guided optimization, saturation/nonlinearity modeling, and uncertainty reporting. We connect these technical choices to key application areas, including trace-gas sensing, reactive and transient media, particulate/aerosol measurements, breath analysis, and precision spectroscopy. Deployment considerations, including sampling interfaces, long-term stability, and calibration transfer, are discussed for harsh or space-limited settings. Remaining challenges in mode matching, baseline control, scalable multiplexing, and low-power integration are outlined to guide next-generation CW-CRDS instruments.