Denture stomatitis is a common oral infection caused by Candid albicans. It occurs under removable dentures due to several causative and contributing factors. If not treated, it can lead to fatal systemic candida infections. Different materials and techniques have been used to treat denture stomatitis; however, no single treatment has succeeded. The purpose of this study was to review novel techniques for incorporating antimicrobial and protein repellent agents into denture acrylic resin materials and their effect on the adhesion of Candida albicans to denture base acrylic resin materials to prevent and/or treat denture stomatitis. A systematic review was conducted in which an electronic search was undertaken using different databases and relevant keywords. The literature search revealed numerous studies describing different antifungal materials incorporated into different denture acrylic resin materials. The investigated materials showed significant antimicrobial activity with slight or no effect on the physical and mechanical properties; however, the optical properties were particularly affected with higher concentrations. The incorporation of antimicrobial agents to reduce or prevent Candida albicans biofilm formation on acrylic resin proved to be very effective, and this effect was found to be proportional to the percentage of the material used. The latter should be considered carefully not to alter the physical, mechanical or optical characteristics of the denture base material.
Denture stomatitis is a multifactorial pathological condition of the oral mucosa that affects up to 72% of denture wearers. It is commonly seen on the palatal mucosa and characterized by erythema on the oral mucosa that are in contact with the denture surface. The aim of this study was to incorporate 2-methacryloyloxyethyl phosphorylcholine (MPC) and dimethylaminohexadecyl methacrylate (DMAHDM) into a high impact polymethylmethacrylate heat-cured denture base acrylic resin as a potential treatment for denture stomatitis. We used a comparative study design to examine the effect of incorporating MPC as a protein repellent agent and DMAHDM as an antifungal agent to prevent the adherence of Candida albicans to the denture base material. The dual incorporation of MPC and DMAHDM reduced C. albicans biofilm colony-forming unit by two orders of magnitude when compared to the control group devoid of the bioactive agents. Although the addition of MPC and DMAHDM alone or in combination significantly reduced the flexural strength of the material, they showed reduced roughness values when compared to control groups. This new denture acrylic resin provides the benefit of enhancing C. albicans biofilm elimination through dual mechanisms of action, which could potentially reduce the prevalence of denture stomatitis.
The aim of this study was to compare patients’ satisfaction and quality of life (QoL) when using implant overdentures vs. conventional dentures. The QoL of Saudi patients who were provided mandibular implant-supported overdentures was assessed using a structured questionnaire. Overall satisfaction; ability to speak, eat, and chew food; comfort; esthetics; stability; and satisfaction of general oral health were measured. A total of 48.3% vs. 6.9% were, overall, very satisfied with their implant overdentures and conventional dentures, respectively. A total of 37.9% of the patients were very satisfied regarding speaking with their implant overdentures vs. 17.2% with conventional dentures. Furthermore, 41.4% were very comfortable with their implant overdentures vs. 5.2% were very comfortable using conventional dentures. However, only 15.5% were very satisfied with the esthetics of the conventional dentures compared to 43.1% being satisfied with implant overdentures. Only 1.7% were very satisfied with the stability of conventional dentures vs. 44.8% being satisfied using implant overdentures. About 8.6% of the candidates were very satisfied regarding chewing food with conventional dentures vs. 36.2% being very satisfied using implant overdentures. Approximately 10.3% were very satisfied with their general oral health using conventional dentures compared to 29.3% being very satisfied using implant overdentures. Mandibular implant overdentures had a strong impact on patients’ quality of life over conventional complete dentures and should be considered the minimum standard of care provided to completely edentulous patients.
Candida albicans (C. albicans) biofilm is a common etiological factor in denture stomatitis. The purpose of this study was to investigate the effects of incorporating 2-methacryloyloxyethyl phosphorylcholine (MPC) as a protein repellent into a new high-impact denture acrylic (HIPA) resin on the surface roughness, solution pH, and C. albicans biofilm adhesion to the denture base. The new acrylic denture resin base was formulated by mixing MPC into HIPA resin at mass fractions of 1.5%, 3%, and 4.5%. Surface roughness was measured using a Mitutoyo surface roughness tester. C. albicans biofilm growth and viability were assessed via colony forming unit counts. The pH of the biofilm growth medium was measured using a digital pH meter. Adding MPC to the HIPA resin at percentages of 1.5% and 3% increased the roughness values significantly (p < 0.05), while adding 4.5% MPC resulted in no difference in roughness values to that of the control group (p > 0.05). All experimental groups demonstrated neutral pH values (pH ≅ 7) and were not significantly different from each other (p > 0.05). Incorporating 2-methacryloyloxyethyl phosphorylcholine at 4.5% resulted in a significant (≅1 log) colony-forming unit reduction compared with the control group with 0% MPC (p < 0.05). A fungal-retarding denture acrylic resin was developed through the incorporation of MPC for its protein-repelling properties. This newly developed denture acrylic material has the potential to prevent oral microbial infections, such as denture stomatitis.
The fracture resistance of computer-aided designing and computer-aided manufacturing CAD/CAM fabricated implant-supported cantilever zirconia frameworks (ISCZFs) is affected by the size/dimension and the micro cracks produced from diamond burs during the milling process. The present in vitro study investigated the fracture load for different cross-sectional dimensions of connector sites of implant-supported cantilever zirconia frameworks (ISCZFs) with different cantilever lengths (load point). A total of 48 ISCZFs (Cercon, Degudent; Dentsply, Deutschland, Germany) were fabricated by CAD/CAM and divided into four groups based on cantilever length and reinforcement of distal-abutment: Group A: 9 mm cantilever; Group B: 9 mm cantilever with reinforced distal-abutment; Group C: 12 mm cantilever; Group D: 12 mm cantilever with reinforced distal-abutment (n = 12). The ISCZFs were loaded using a universal testing machine for recording the fracture load. Descriptive statistics, ANOVA, and Tukey’s test were used for the statistical analysis (p < 0.05). Significant variations were found between the fracture loads of the four ISCZFs (p = 0.000); Group-C and B were found with the weakest and the strongest distal cantilever frameworks with fracture load of 670.39 ± 130.96 N and 1137.86 ± 127.85 N, respectively. The mean difference of the fracture load between groups A (810.49 + 137.579 N) and B (1137.86 ± 127.85 N) and between C (670.39 ± 130.96 N) and D (914.58 + 149.635 N) was statistically significant (p = 0.000). Significant variations in the fracture load between the ISCZFs with different cantilever lengths and thicknesses of the distal abutments were found. Increasing the thickness of the distal abutment only by 0.5 mm reinforces the distal abutments by significantly increasing the fracture load of the ISCZFs. Therefore, an increase in the thickness of the distal abutments is recommended in patients seeking implant-supported distal cantilever fixed prostheses.
Background: A major disadvantage of polymethyl methacrylate (PMMA) acrylic resins is susceptibility to biofilm accumulation. The incorporation of antimicrobial agents is a reliable prevention technique. The purpose of this study is to investigate the effect of incorporating dimethylaminohexadecyl methacrylate (DMAHDM) and/or 2-methacryloyloxyethyl phosphorylcholine (MPC) into heat-polymerized (HP) and 3D-printed (3DP) denture base materials on the flexural strength, modulus of elasticity, and surface hardness. Methods: DMAHDM and/or MPC were mixed with the acrylic resin liquid of a heat-polymerized (ProBase Hot) and a 3D printed (NextDent Denture 3D) material at mass fractions of 1.5% and 3% and a combination of 3% MPC and 1.5% DMAHDM. Results: Significant differences in mechanical properties between the control and experimental groups have been detected (p-value < 0.0001). In HP materials, the addition of DMAHDM and/or MPC generally decreased the flexural strength, from (151.18 MPa) in G1 down to (62.67 MPa) in G5, and surface hardness, from (18.05 N/mm2) down to (10.07 N/mm2) in G5. Conversely, in 3DP materials, flexural strength was slightly enhanced, from (58.22 MPa) in G1 up to (62.76 MPa) in G6, although surface hardness was consistently reduced, from (13.57 N/mm2) down to (5.29 N/mm2) in G5. Conclusion: It is recommended to carefully optimize the concentrations of DMAHDM and/or MPC to maintain mechanical integrity.