sarula Chen

Dr. sarula Chen

Anhui Jianzhu University, Hefei, Anhui, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Energy Conversion and Management
Verified
Journal Article
Closed access
YYYang Yang
Yang Yang
sarula Chensarula Chen
sarula Chen
TCTianxin Chang
Tianxin Chang
JMJunrong Ma
Junrong Ma
YSYong Sun
Yong Sun


18 April 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
HTHaolin Tian
Haolin Tian
sarula Chensarula Chen
sarula Chen
QZQing Guo Zhang
Qing Guo Zhang
CHChen Hu
Chen Hu
WZWeiyi Zhang
Weiyi Zhang
HYHao Yu
Hao Yu
China’s urbanization process has entered the stage of mid-to-late transformation and upgrading, with the urbanization and population growth rates having passed the turning point. Urban renewal has become an increasingly important issue, among which the renovation of old residential areas holds enormous potential. The improvement of the living environment is urgent, and enhancing the microclimate to improve the livability and comfort of outdoor residential spaces is a critical factor. This study presents for the first time a quantitative framework for multifactor synergistic optimization by coupling building layout closure and material albedo effects. This paper takes typical old residential areas in Fuyang as an example and uses 3D microclimate simulation software (ENVI-met Version 4.3) to establish a simulation model. It evaluates the microclimate and thermal comfort under different building layouts, green infrastructures, building envelope materials, and various surface materials. The results show that: (1) Regarding building layout, the point-cluster layout generally results in the best improvement of daily cumulative physiological equivalent temperature (PET) values, followed by row-type and enclosed layouts; (2) The optimal solutions for improving the daily average PET value are as follows: using glass as the building envelope material in the point-cluster layout; 100% tree coverage in the row-type layout; and 100% asphalt coverage as the surface material in the point-cluster layout. These three conditions reduce the daily average PET by 3.51 °C, 23.87 °C, and 2.65 °C, respectively; (3) The degree of impact on PET is ranked as: green infrastructure configuration > building layout > building envelope materials > surface materials; (4) When the building layout of the residential area is more enclosed, such as using row-type or enclosed layouts, the order of building envelope materials improving thermal comfort is: brick, concrete, and glass. When the building layout is less enclosed, such as using point-cluster layouts, the order of building envelope materials improving thermal comfort is: glass, brick, and concrete. Therefore, it is concluded that applying point-cluster layout in buildings, using glass as the building envelope material, and having 100% coverage of asphalt pavement as the surface material and 100% coverage of trees can maximize the improvement of the thermal environment of the buildings. The conclusion is applicable to old residential areas in warm temperate semi-humid monsoon climatic zones characterized by high densities (floor area ratios > 2.5) and high rates of hardening of the ground (≥80%), and is particularly instructive for medium-sized urban renewal projects with an urbanization rate between 45% and 60%.

9 October 2023 in Fire
Verified
Journal Article
Open access
PDF file
YWYunfa Wu
Yunfa Wu
BHbin hua
bin hua
sarula Chensarula Chen
sarula Chen
JYJimo Yang
Jimo Yang
In the history of human civilization, traditional villages and buildings have been significantly threatened by fire. As an essential part of Huizhou traditional architecture, fire seal walls play a crucial role in preserving Huizhou architecture by effectively blocking the spread of fire. However, with economic and social development, the Huizhou fire seal wall’s original fire prevention function has been unable to meet the needs of modern fire protection. This study aims to explore the fire performance of different types of Huizhou fire seal walls to provide a reference guide for future fire protection, optimization, and transformation of traditional buildings. In this paper, 3D models of traditional buildings with fire seal walls were built with FDS, and the performance of the different kinds of fire seal walls was simulated under the influence of wind speeds, building spacing, and the height of the vertical ridge of the fire seal wall. The results showed that, under the same conditions, a fire seal wall with a single eave is superior to fire seal walls with quintuple eaves in terms of performance, and fire seal walls with quintuple eaves are superior to fire seal walls with triple eaves in the middle and late stages of a fire. In addition, wind speeds, building spacing, and the height of the vertical ridge have different effects on the fire performance of seal walls. Lower wind speeds can reduce the fire performance of fire seal walls, and no wind and higher wind speeds have no significant effect on the fire performance of fire seal walls, while increasing the height of the vertical ridge and fire spacings appropriately can improve the fire performance of fire seal walls. This study provides a reference guide for future fire protection, optimization, and transformation of Huizhou fire seal walls, which can help improve the fire safety of traditional buildings.

2 December 2023 in Energy Conversion and Management
Verified
Journal Article
Closed access
YYYang Yang
Yang Yang
sarula Chensarula Chen
sarula Chen

23 July 2024 in Building Simulation
Verified
Journal Article
Closed access
PDF file
YYYang Yang
Yang Yang
sarula Chensarula Chen
sarula Chen
JZJiqiang Zhang
Jiqiang Zhang
ZZZhenya Zhang
Zhenya Zhang
SLShuying Li
Shuying Li
XXXiuyi Xiao
Xiuyi Xiao