Seo-A Park

Ms. Seo-A Park

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
JYJaeeun Yoo
Jaeeun Yoo
HPHye-Sun Park
Hye-Sun Park
JKJoungOk Kim
JoungOk Kim
SCSang-Ik Cho
Sang-Ik Cho
SJSeong Hwan Jo
Seong Hwan Jo
Eun-Jee OhEun-Jee Oh
Eun-Jee Oh
Background/Objectives: The Elecsys HCV Duo immunoassay simultaneously detects HCV core antigen (HCV Ag) and anti-HCV antibodies in a single sample. We evaluated its clinical performance against a standard-of-care reference algorithm of anti-HCV antibody and HCV RNA testing. Methods: We retrospectively analyzed 1332 residual serum or plasma samples tested with reference HCV RNA assays and the Alinity i Anti-HCV assay. Samples were classified as reference-positive, indicating current or past HCV infection (n = 166; 88 RNA+/Ab+ with active infection and 78 RNA−/Ab+ with resolved or treated infection), or reference-negative (n = 1166; RNA−/Ab−), including 1000 randomly selected blood donor samples. All specimens were tested with the Elecsys HCV Duo (cobas® e 801, Roche Diagnostics). Positive and negative percent agreements (PPA and NPA) were calculated against the combined reference standard. Results were further analyzed by infection status and viral load. No HCV RNA+/anti-HCV− (window-period) specimens were available. Results: Overall agreement was high (PPA 98.8% [164/166; 95% CI, 95.7–99.9%]; NPA 99.9% [1165/1166; 95% CI, 99.5–100.0%]). Agreement of the anti-HCV component with the Alinity i Anti-HCV assay was identical (PPA 98.8%, NPA 99.9%). The HCV Duo Ag component showed a PPA of 60.2% (95% CI, 49.2–70.5%) and NPA of 99.0% (95% CI, 98.3–99.5%) against HCV RNA detection. The Ag module was also reactive in 12 of 78 (15.4%) RNA−/Ab+ specimens, all from previously treated patients; thus, 53 of 65 (81.5%) dual Ag/Ab-reactive specimens had detectable HCV RNA. HCV Ag positivity was highest at HCV RNA ≥106 IU/mL (77.4%, 41/53), compared with 32.1% (9/28) at 104–106 IU/mL and 42.9% (3/7) at <104 IU/mL. Receiver operating characteristic analysis of the Ag component yielded an area under the curve of 0.920 (95% CI, 0.904–0.934). Conclusions: The Elecsys HCV Duo demonstrated high overall agreement with the reference methods, supporting its potential as a single-step screening test for HCV infection. Most, but not all, dual Ag/Ab-reactive specimens were viremic, so this result may help prioritize anti-HCV-positive individuals for linkage to care; however, the assay does not replace HCV RNA testing, which remains necessary to confirm active infection, particularly in Ag-negative or previously treated individuals. Because no window-period specimens were included, the potential of the assay for earlier detection of acute infection could not be evaluated.

21 July 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
HLHyeyoung Lee
Hyeyoung Lee
ACAe-Ran Choi
Ae-Ran Choi
HPHye-Sun Park
Hye-Sun Park
JKJoungOk Kim
JoungOk Kim
SPSeo-A Park
Seo-A Park
Eun-Jee OhEun-Jee Oh
Eun-Jee Oh
Background/Objectives: Since the World Health Organization (WHO) recommended HIV self-testing as an alternative to traditional facility-based testing in 2016, it has been increasingly adopted worldwide. This study aimed to evaluate the performance of the ConfiSign HIV Self-Test (GenBody Inc., Republic of Korea), a newly developed blood-based immunochromatographic assay for the qualitative detection of total antibodies (IgG and IgM) against HIV-1/HIV-2. Methods: The evaluation included four components: (1) retrospective analysis of 1400 archived serum samples (400 HIV-positive and 1000 HIV-negative samples), (2) prospective self-testing by 335 participants (112 HIV-positive participants and 223 individuals with an unknown HIV status, including healthy volunteers), (3) assessment using seroconversion panels and diverse HIV subtypes, and (4) analytical specificity testing for cross-reactivity and interference. The Elecsys HIV combi PT and Alinity I HIV Ag/Ab Combo assays were used as reference assays. Results: In retrospective testing, the ConfiSign HIV Self-Test achieved a positive percent agreement (PPA) of 100%, a negative percent agreement (NPA) of 99.2%, and a Cohen’s kappa value of 0.986, showing excellent agreement with the reference assays. In the prospective study, the test showed 100% sensitivity and specificity, with a low invalid result rate of 1.8%. All HIV-positive samples, including those with low signal-to-cutoff (S/Co) values in the Alinity I assay, were correctly identified. The test also reliably detected early seroconversion samples and accurately identified a broad range of HIV-1 subtypes (A, B, C, D, F, G, CRF01_AE, CRF02_AG, and group O) as well as HIV-2. No cross-reactivity or interference was observed with samples that were positive for hepatitis viruses, cytomegalovirus, Epstein–Barr virus, varicella zoster virus, influenza, HTLV-1, HTLV-2, or malaria. Conclusions: The ConfiSign HIV Self-Test demonstrated excellent sensitivity, specificity, and robustness across diverse clinical samples, supporting its reliability and practicality as a self-testing option for HIV-1/2 antibody detection.