Seren Acarer Arat

Dr. Seren Acarer Arat

Environmental Engineering Department, Istanbul Technical University, Istanbul, İstanbul, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2023 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
Seren Acarer AratSeren Acarer Arat
Seren Acarer Arat
Microplastics (MPs) cannot be completely removed from water/wastewater in conventional wastewater treatment plants (WWTPs) and drinking water treatment plants (DWTPs). According to the literature analysis, membrane technologies, one of the advanced treatment technologies, are the most effective and promising technologies for MP removal from water and wastewater. In this paper, firstly, the properties of MPs commonly present in WWTPs/DWTPs and the MP removal efficiency of WWTPs/DWTPs are briefly reviewed. In addition, research studies on MP removal from water/wastewater by microfiltration (MF), ultrafiltration (UF), nanofiltration (NF), reverse osmosis (RO), and membrane bioreactors (MBRs) are reviewed. In the next section, membrane filtration is compared with other methods used for MP removal from water/wastewater, and the advantages/disadvantages of the removal methods are discussed. Moreover, the problem of membrane fouling with MPs during filtration and the potential for MP release from polymeric membrane structure to water/wastewater are discussed. Finally, based on the studies in the literature, the current status and research deficiencies of MP removal by membrane technologies are identified, and recommendations are made for further studies.

25 January 2023 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
Seren Acarer AratSeren Acarer Arat
Seren Acarer Arat
Since wastewater treatment plants (WWTPs) cannot completely remove microplastics (MPs) from wastewater, WWTPs are responsible for the release of millions of MPs into the environment even in 1 day. Therefore, knowing the sources, properties, removal efficiencies and removal mechanisms of MPs in WWTPs is of great importance for the management of MPs. In this paper, firstly the sources of MPs in WWTPs and the quantities and properties (polymer type, shape, size, and color) of MPs in influents, effluents, and sludges of WWTPs are presented. Following this, the MP removal efficiency of different treatment units (primary settling, flotation, biological treatment, secondary settling, filtration-based treatment technologies, and coagulation) in WWTPs is discussed. In the next section, details about MP removal mechanisms in critical treatment units (settling and flotation tanks, bioreactors, sand filters, membrane filters, and coagulation units) in WWTPs are given. In the last section, the mechanisms and factors that are effective in adsorbing organic–inorganic pollutants in wastewater to MPs are presented. Finally, the current situation and research gap in these areas are identified and suggestions are provided for topics that need further research in the future.


1 February 2022 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
MÖMehmet Şükrü Özçoban
Mehmet Şükrü Özçoban
Seren Acarer AratSeren Acarer Arat
Seren Acarer Arat
NTNeşe Tüfekci
Neşe Tüfekci
Landfilling is one of the most widely used methods to reduce the impact on the environment and human health by ensuring the management of solid wastes. For the process in question to be called landfill, the landfill leachate must be controlled and liner impermeability conditions must be provided. For this reason, compacted clay liners (CCL) and geosynthetic clay liners (GCL) with very low hydraulic conductivity are often used as hydraulic barriers in landfills to prevent the risk of leachate mixing with groundwater. However, as a result of various interactions between leachate–clay liners, changes occur in the hydraulic conductivity of the liners. In this review, the change (increase/decrease) in the hydraulic conductivity of the landfill liners caused by the contaminants in the leachate composition and the mechanisms responsible for this change were examined. In addition, deficiencies in the literature on this subject were identified and directions for future studies were presented.


20 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Seren Acarer AratSeren Acarer Arat
Seren Acarer Arat
İnci Pirİnci Pir
İnci Pir
Mertol TufekciMertol Tufekci
Mertol Tufekci
GDGüler Türkoğlu Demirkol
Güler Türkoğlu Demirkol
NTNeşe TÜFEKÇİ
Neşe TÜFEKÇİ
In this study, polyethersulfone (PES) and polyvinylidene fluoride (PVDF) microfiltration membranes containing polyvinylpyrrolidone (PVP) with and without support layers of 130 and 150 μm thickness are manufactured using the phase inversion method and then experimentally characterised. For the characterisation of membranes, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and pore size analysis are performed, the contact angle and water content of membranes are measured and the tensile test is applied to membranes without support layers. Using the results obtained from the tensile tests, the mechanical properties of the halloysite nanotube (HNT) and nano-silicon dioxide (nano SiO2) reinforced nanocomposite membranes are approximately determined by the Mori–Tanaka homogenisation method without applying any further mechanical tests. Then, plain polymeric and PES and PVDF based nanocomposite membranes are modelled using the finite element method to determine the effect of the geometry of the membrane on the mechanical behaviour for fifteen different geometries. The modelled membranes compared in terms of three different criteria: equivalent stress (von Mises), displacement, and in-plane principal strain. Based on the data obtained from the characterisation part of the study and the numerical analysis, the membrane with the best performance is determined. The most appropriate shape and material for a membrane for water treatment is specified as a 1% HNT doped PVDF based elliptical membrane.