Seyedamin Valedsaravi

Dr. Seyedamin Valedsaravi

Rovira i Virgili University, Tarragona, Catalonia, Spain
+2
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
Seyedamin ValedsaraviSeyedamin Valedsaravi
Seyedamin Valedsaravi
Abdelali El AroudiAbdelali El Aroudi
Abdelali El Aroudi
LMLuis Martinez-Salamero
Luis Martinez-Salamero
The emergence of DC fast chargers for electric vehicle batteries (EVBs) has prompted the design of ad-hoc microgrids (MGs), in which the use of a solid-state transformer (SST) instead of a low-frequency service transformer can increase the efficiency and reduce the volume and weight of the MG electrical architecture. Mimicking a conventional gasoline station in terms of service duration and service simultaneity to several customers has led to the notion of ultra-fast chargers, in which the charging time is less than 10 min and the MG power is higher than 350 kW. This survey reviews the state-of-the-art of DC ultra-fast charging stations, SST transformers, and DC ultra-fast charging stations based on SST. Ultra-fast charging definition and its requirements are analyzed, and SST characteristics and applications together with the configuration of power electronic converters in SST-based ultra-fast charging stations are described. A new classification of topologies for DC SST-based ultra-fast charging stations is proposed considering input power, delta/wye connections, number of output ports, and power electronic converters. More than 250 published papers from the recent literature have been reviewed to identify the common understandings, practical implementation challenges, and research opportunities in the application of DC ultra-fast charging in EVs. In particular, the works published over the last three years about SST-based DC ultra-fast charging have been reviewed.

19 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
Seyedamin ValedsaraviSeyedamin Valedsaravi
Seyedamin Valedsaravi
Abdelali El AroudiAbdelali El Aroudi
Abdelali El Aroudi
JBJosé Antonio Barrado-Rodrigo
José Antonio Barrado-Rodrigo
Walid IssaWalid Issa
Walid Issa
LMLuis Martinez-Salamero
Luis Martinez-Salamero
Load and supply parameters may be uncertain in microgrids (MGs) due for instance to the intermittent nature of renewable energy sources among others. Guaranteeing reliable and stable MGs despite parameter uncertainties is crucial for their correct operation. Their stability and dynamical features are directly related to the controllers’ parameters and power-sharing coefficients. Hence, to maintain power good quality within the desirable range of system parameters and to have a satisfactory response to sudden load changes, careful selection of the controllers and power-sharing coefficients are necessary. In this paper, a simple design approach for the optimal design of controllers’ parameters is presented in an islanded MG. To that aim, an optimization problem is formulated based on a small-signal state-space model and solved by three different optimization techniques including particle swarm optimization (PSO), genetic algorithm (GA), and a proposed approach based on the combination of both PSO and GA. The optimized coefficients are selected to guarantee desirable static and dynamic responses in a wide range of operations regardless of the number of inverters, system configuration, output impedance differences, and load types. Through the proposed design and tuning method, the performance of the MG is improved as compared to those obtained using state-of-art techniques. This fact is demonstrated by using numerical simulations performed on a detailed model implemented in PSIM© software.

10 May 2023 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Open access
PDF file
Seyedamin ValedsaraviSeyedamin Valedsaravi
Seyedamin Valedsaravi
AAAbdelali El Aroudi
Abdelali El Aroudi
JBJose A. Barrado-Rodrigo
Jose A. Barrado-Rodrigo
MHMohsen Hamzeh
Mohsen Hamzeh
LMLuis Martínez-Salamero
Luis Martínez-Salamero
The use of Active Power Filters (APFs) in future power grids with high penetration of nonlinear loads is unavoidable. Voltage Source Inverters (VSIs) interfacing Photovoltaic (PV) generator could play the APF role in addition to power supply. In this paper, the control of a PV-fed multifunctional grid-connected three-phase VSI is addressed with nonlinear and unbalanced load. The control objective is threefold. The first one is to deliver the maximum available power from the PV source to the grid satisfying power quality standards. The second one is the Voltage Balancing Control for DC-link capacitors to guarantee correct operation of the VSI. The last one is shunt APF control to compensate for nonlinear and unbalanced load harmonics, reactive power, and unbalanced sequences. A quasi-Proportional-Resonant (PR) controller with harmonic compensators is proposed for the current control loop. The quasi-PR controller parameters are determined through optimization algorithms such as Particle Swarm Optimization (PSO), Genetic Algorithm (GA), and a combination of both PSO and GA. The aim of the objective function is to improve static and dynamic behavior. The different gains at the fundamental resonant frequency and the selected odd harmonics are obtained for the proposed quasi-PR controller. The dynamic characteristics of the optimized quasi-PR controllers show superiority against conventional ones in terms of gain margin, phase margin, overshoot, and robustness. With the proposed control scheme, the harmonics, reactive power, and unbalanced sequences are appropriately compensated. The performance of the PV-fed VSI shunt APF under irradiance change, load change, and distorted grid voltage conditions is validated through numerical simulations performed on $$\hbox {PSIM}^{\copyright }$$ PSIM © software. The results show that the grid currents Total Harmonic Distortion for irradiance change case study are $$4.57\%$$ 4.57 % , $$4.57\%$$ 4.57 % , and $$3.22\%$$ 3.22 % in phase a, b, and c with the proposed control method, while they are $$9.25\%$$ 9.25 % , $$5.65\%$$ 5.65 % , and $$10.12\%$$ 10.12 % with conventional instantaneous $$p-q$$ p - q theory.

14 February 2025 in IEEE Access
Verified
Journal Article
Open access
Seyedamin ValedsaraviSeyedamin Valedsaravi
Seyedamin Valedsaravi
Global warming has accelerated the transition towards clean and renewable energy (RE) resources. However, the intermittent nature of these resources presents challenges to their effective integration into power systems. A practical and sustainable solution involves storing the generated energy in energy storage systems (ESS) or converting it into renewable fuels and chemicals through power-to-x (PtX) processes. The latter has gained increased attention because of its ability to stabilize energy systems over extended periods. The application of PtX enables decarbonization of sectors in which direct electrification is challenging. PtX microgrids (MG) can operate in either grid-connected/on-grid or islanded/off-grid modes. Each operation mode requires specific equipment and strategies to ensure the power balance, stability, and resilience within the power system. Choosing the optimal operational mode for a PtX MG can be complex, because the on-grid and off-grid configurations differ significantly in terms of both technical performance and financial viability. Therefore, this paper presents a techno-commercial comparative assessment of a real industrial RE-based PtX MG, focusing on hydrogen (H2) production plants, under both operational modes. First, the essential components of the PtX MG and additional equipment required for each mode are introduced. Second, financial analysis evaluates the contribution of various equipment costs to the total equipment cost. Finally, the steady-state and transient performances of the on-grid and off-grid PtX MG are compared. These include load flow analysis (LFA), short circuit analysis (SCA), harmonic flow analysis (HFA), and low-voltage ride-through (LVRT) simulations. The PtX MG power system is modeled using PowerFactory software.

18 June 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
Seyedamin ValedsaraviSeyedamin Valedsaravi
Seyedamin Valedsaravi
KMKuntal Mandal
Kuntal Mandal
Abdelali El AroudiAbdelali El Aroudi
Abdelali El Aroudi
LMLuis Martinez-Salamero
Luis Martinez-Salamero
This article presents a fixed-frequency digital sliding mode control (SMC) technique to perform power factor correction (PFC) for electric vehicle (EV) charging applications. A three-phase four-wire boost rectifier with split-capacitor topology is selected. Using system model, three decoupled sliding mode controllers are designed to achieve loss-free resistor (LFR) behavior in each phase for PFC. The control law and the dynamic model of the rectifier are obtained by imposing sliding-mode regime in discrete time. To obtain simple expression of the duty cycle for ease of digital implementation in natural frame, the discrete-time model of the system has been used with reasonable approximations. Despite the theoretical stability of the closed-loop system, practical implementation of the control law is limited by digital control delays. To mitigate this problem in practice, a modified control law is proposed to ensure stability by scaling the weighted error in the expression of the control law resulting from the ideal SMC. The combination of the topology and the control method in the natural frame shows improved performance compared to the existing literature. Theoretical predictions are validated by several numerical simulations of the switched model and experimental measurements under different practical scenarios.

4 August 2022 in IFAC-PapersOnLine
Verified
Journal Article
Closed access
Seyedamin ValedsaraviSeyedamin Valedsaravi
Seyedamin Valedsaravi
AAAbdelali El Aroudi
Abdelali El Aroudi
LSLuis Martínez Salamero
Luis Martínez Salamero