Shahid Jaman

Mr. Shahid Jaman

PhD Researcher at EPOWERS-MOBI Research Team, Vrije Universiteit Brussel

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
Shahid JamanShahid Jaman
Shahid Jaman
BVBoud Verbrugge
Boud Verbrugge
OGOscar Hernandez Garcia
Oscar Hernandez Garcia
MAMohamed Abdel-Monem
Mohamed Abdel-Monem
OBOliver Blum
Oliver Blum
Omar HegazyOmar Hegazy
Omar Hegazy
Vehicle-to-Grid (V2G) technology is viewed as a viable solution to offer auxiliary power system services. Currently, V2G operation is only possible through DC chargers using the CHAdeMO connector with the necessary communication protocol. However, in Europe, for high-power DC charging (>50 kW), the Combined Charging Service (CCS) Type 2 is preferred over CHAdeMO. Therefore, this work presents the development of a V2G testing system with a Combo CCSType 2 charger including communication via the ISO 15118-2 protocol. The BOSCH passenger car with a 400 V battery pack is used to test and validate the technical feasibility of V2G charging via a Combo CCS Type 2 connector standard. The V2G feature is characterized in terms of efficiency, signal delay, response proportionality, magnitude accuracy and noise precision. A data driven V2G charger simulation model based on the real-time data is also developed in MATLAB/Simulink. The performance under various operating settings is presented in the outcomes, emphasizing the need for appropriate hardware calibration, and understanding while delivering standard-compliant grid control services using V2G technology. Finally, the results of the simulation model are compared with the real hardware results in terms of error, noise level and data magnitude accuracy.

25 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
Shahid JamanShahid Jaman
Shahid Jaman
Sajib ChakrabortySajib Chakraborty
Sajib Chakraborty
DTDuong Tran
Duong Tran
Thomas GeuryThomas Geury
Thomas Geury
MBMohamed El Baghdadi
Mohamed El Baghdadi
Omar HegazyOmar Hegazy
Omar Hegazy
This article reviews the different topologies compatible with V2G feature and control approaches of integrated onboard charger (iOBC) systems for battery electric vehicles (BEVs). The integrated topologies are presented, analyzed, and compared in terms of component count, switching frequency, total harmonic distortion (THD), charging and traction efficiencies, controllability, reliability and multifunctionality. This paper also analyzes different control approaches for charging and traction modes. Moreover, the performance indices such as setting time, rise time, overshoot, etc., are summarized for charging and traction operations. Additionally, the feasibility of a Level 3 charging (AC fast charging with 400 Vac) of up to 44 kW iOBC is discussed in terms of converter efficiencies with different switching frequencies and switch technologies such as SiC and GaN. Finally, this paper explores the power density trends of different commercial integrated charging systems. The power density trend analysis could certainly help researchers and solution engineers in the automotive industry to select the suitable converter topology to achieve the projected power density.

10 October 2023 in IEEE Access
Verified
Journal Article
Open access
Shahid JamanShahid Jaman
Shahid Jaman
MAMohamed Abdel-Monem
Mohamed Abdel-Monem
Thomas GeuryThomas Geury
Thomas Geury
Omar HegazyOmar Hegazy
Omar Hegazy
This research paper proposes a novel grid-connected modular inverter for an integrated bidirectional charging station for residential applications. The system is designed to support the electrical grid by providing buffering services and enhancing the stability of the grid. The proposed system consists of a modular bidirectional inverter which can work as an EV charger. The system can operate in different modes such as charging and discharging the EV battery, storing excess energy from the grid during low-demand periods, and supplying energy back to the grid during high-demand periods. A low-level control strategy based on the droop control technique and feedforward decoupling is developed to manage the power flow between the EV battery, household load and the grid. The performance of the proposed system is evaluated through simulation studies in MATLAB/Simulink software. The results show the system’s ability to support the grid during peak demand and boost renewable energy integration. It also acts as a backup power supply during outages, increasing reliability. The experimental validation in a laboratory environment confirms an 87% charging efficiency with 35% SoC, drawing 6.3 kW from the grid. Returning power to the grid achieves a V2G efficiency of around 94%, delivering 8.6 kW AC output and 8.77 kW battery input at a 55% SoC.

25 January 2024 in IEEE Access
Verified
Journal Article
Open access
Ekaterina AbramushkinaEkaterina Abramushkina
Ekaterina Abramushkina
GMGamze Egin Martin
Gamze Egin Martin
ASAtila Sen
Atila Sen
Shahid JamanShahid Jaman
Shahid Jaman
HRHaaris Rasool
Haaris Rasool
Omar HegazyOmar Hegazy
Omar Hegazy
Modern Electric Vehicles (EVs) require high power and high efficient powertrains to extend their power range. A key element of the electric powertrain is its drive with an electric machine controlled by a traction inverter. A cooling system dissipates heat generated due to the losses in this inverter and keeps its temperature within limits, i.e. below the operational maximum value. Indirect cooling systems are often the preferred solution due to their easy implementation and robust separation of the electric/electronic parts and the coolant circuit. Indirect cooling comes with additional surface interfaces, hence thermal barriers and increased thermal resistance for the losses’ heat flow path. One way to increase the system’s heat transfer coefficient is by implementing power electronics with dual-sided cooling (DSC) solutions and by enhancing surface structures for the cold plates. Manufacturing complex cold plate solutions with internal surface-enhancing structures by way of classical techniques (e.g. aluminum extrusion with CNC machining) can be difficult, costly, or even not possible. Sealed one-piece solutions are preferred, without the need to weld parts or use screws, glue, gaskets, etc. 3D metal printing allows to manufacture of a one-unit compact, light, and reliable cold plate. This study shows the advantages and limitations of a 3D metal-printed inverter cold plate by presenting the microchannel design, numerical thermal simulations, and experimental results for the liquid cooled DSC SiC and Si inverters. This work explores the compatible use of 3D metal printing solutions, which will aid the development of modern high-power density EVs.

1 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
MHMd. Mahamudul Hasan
Md. Mahamudul Hasan
Shahid JamanShahid Jaman
Shahid Jaman
Thomas GeuryThomas Geury
Thomas Geury
Omar HegazyOmar Hegazy
Omar Hegazy
This paper presents a comprehensive performance assessment of a two-stage power electronic (PE) converter for interfacing the grid of a lithium-ion battery energy storage system (Li-BESS) for building-integrated PV (BIPV) applications. A performance assessment of the control system was conducted for the two-stage PE interface with a common DC-link, which consisted of a bi-directional boost converter with a cascaded PI controller and an AC/DC converter with proportional-integral (PI) and proportional-resonant (PR) controllers. The assessment covered loss analysis and useful lifetime estimation for the 10 kW PE interface with a wide-bandgap SiC power MOSFET at different loads for both the charging and discharging modes of a 50 kWh lithium-ion battery system. Additionally, a performance comparison of various switching frequencies was performed. It was observed that the system was stable up to a switching frequency of 30 kHz, and that increasing the switching frequency improved the responsiveness of the converter by decreasing the settling time; however, there were diminishing returns at higher switching frequencies. To obtain a proper balance between responsiveness and lower loss, a switching frequency of 10 kHz was selected.

16 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
HRHaaris Rasool
Haaris Rasool
BVBoud Verbrugge
Boud Verbrugge
Shahid JamanShahid Jaman
Shahid Jaman
Ekaterina AbramushkinaEkaterina Abramushkina
Ekaterina Abramushkina
Thomas GeuryThomas Geury
Thomas Geury
Omar HegazyOmar Hegazy
Omar Hegazy
Emerging wide bandgap (WBG) semiconductors, such as silicon carbide (SiC), will enable chargers to operate at higher switching frequencies, which grants the ability to deliver high power and enhances efficiency. This paper addresses the modeling of a double-sided cooling (DSC) SiC technology-based off-board charger for battery electric buses (BEBs) and the design of its control and real-time (RT) implementation. A three-phase active front-end (AFE) rectifier topology is considered in the modeling and control system design for the active part of the DC off-board charger. The control system consists of a dual-loop voltage–current controller and is used to ensure AC to DC power conversion for charging and to achieve the targeted grid current total harmonic distortion (THD) and unity power factor (PF). Linear and nonlinear simulation models are developed in MATLAB/Simulink for optimum control design and to validate the voltage and current control performances. Four types of controllers (i.e., proportional–integral (PI), lead–lag, proportional–resonant (PR), and modified proportional–resonant (MPR)) are designed as current controllers, and a comparative analysis is conducted on the simulation model. In addition, the final design of the dual-loop controller is implemented on the RT–FPGA platform of dSpace MicroLabBox. It is then tested with the charger to validate the control performance with experimental data. The simulation and experimental results demonstrate the correct operation of the converter control performance by tracking the reference commands.