Shao Min Huang

Dr. Shao Min Huang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
PLPei-Hua Lee
Pei-Hua Lee
SHShao Min Huang
Shao Min Huang
YTYi-Ching Tsai
Yi-Ching Tsai
YWYu-Ting Wang
Yu-Ting Wang
FCFatt Yang Chew
Fatt Yang Chew
Contrast-induced nephropathy (CIN) represents a significant complication associated with the use of iodinated contrast media (ICM), especially in individuals with preexisting renal impairment. The pathophysiology of CIN encompasses oxidative stress, inflammation, endothelial dysfunction, and hemodynamic disturbances, resulting in acute kidney injury (AKI). Early detection is essential for effective management; however, conventional markers like serum creatinine (sCr) and estimated glomerular filtration rate (eGFR) exhibit limitations in sensitivity and timeliness. This review emphasizes the increasing significance of novel biomarkers in enhancing early detection and risk stratification of contrast-induced nephropathy (CIN). Recent advancements in artificial intelligence and computational analytics have improved the predictive capabilities of these biomarkers, enabling personalized risk assessment and precision medicine strategies. Additionally, we discuss mitigation strategies, including hydration protocols, pharmacological interventions, and procedural modifications, aimed at reducing CIN incidence. Incorporating biomarker-driven assessments into clinical decision-making can enhance patient management and outcomes. Future research must prioritize the standardization of biomarker assays, the validation of predictive models across diverse patient populations, and the exploration of novel therapeutic targets. Utilizing advancements in biomarkers and risk mitigation strategies allows clinicians to improve the safety of contrast-enhanced imaging and reduce the likelihood of renal injury.

25 August 2023 in Medicine
Verified
Journal Article
Open access
SLSuat Yee Lee
Suat Yee Lee
JLJung-Nien Lai
Jung-Nien Lai
YHYulin Haw
Yulin Haw
LCLu-Ting Chiu
Lu-Ting Chiu
SHShao Min Huang
Shao Min Huang
FCFatt Yang Chew
Fatt Yang Chew
The association between vesicoureteral reflux (VUR) and chronic kidney disease (CKD) risk remains unestablished. We investigated the incidence of CKD in children with VUR in Taiwan and evaluated whether they had a higher risk of CKD than the general population. A nationwide population-based cohort study was conducted among children with VUR identified using Taiwan’s National Health Insurance Research Database from 2000 to 2013. VUR was defined according to the International Classification of Diseases, Ninth Revision, Clinical Modification codes. We identified the children with VUR and randomly selected comparison children according to a 1:1 ratio, matching them by age, gender, index year and comorbidity using data from the National Health Insurance Research Database. In total, 8648 children with VUR and 8648 comparison children were included. All children were followed from the study date until a diagnosis of CKD, termination of insurance, or the end of 2013. Cox proportional hazards regressions were performed to compare the hazard ratios for CKD between the 2 cohorts. Incident cases of CKD were identified. After adjustment for potential confounders, the study cohort was independently associated with a higher risk of CKD (adjusted hazard ratio, 3.78; 95% confidence interval, 2.10–7.18). This population-based cohort study indicated that children with VUR have a higher risk of CKD than those without VUR.

3 June 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SLSuat Yee Lee
Suat Yee Lee
SCShen Cheak Currina Chew
Shen Cheak Currina Chew
PLPei Hua Lee
Pei Hua Lee
HCHung Da Chen
Hung Da Chen
SHShao Min Huang
Shao Min Huang
FCFatt Yang Chew
Fatt Yang Chew
Background: The use of three-dimensional(3D) printing is broadly across many medical specialties. It is an innovative, and rapidly growing technology to produce custom anatomical models and medical conditions models for medical teaching, surgical planning, and patient education. This study aimed to evaluate the accuracy and feasibility of 3D printing in creating a superficial femoral artery pseudoaneurysm model based on CT scans for endovascular training. Methods: A case of a left superficial femoral artery pseudoaneurysm was selected, and the 3D model was created using DICOM files imported into Materialise Mimics 22.0 and Materialise 3-Matic software, then printed using vat polymerization technology. Two 3D-printed models were created, and a series of comparisons were conducted between the 3D segmented images from CT scans and these two 3D-printed models. Ten comparisons involving internal diameters and angles of the specific anatomical location were measured. Results: The study found that the absolute mean difference in diameter between the 3D segmented images and the 3D printed models was 0.179±0.145 mm and 0.216±0.143mm, respectively, with no significant difference between the two sets of models. Additionally, the absolute mean difference in angle was 0.99±0.65° and 1.00±0.91°, respectively, and the absolute mean difference in angle between the two sets of data was not significant. Bland-Altman analysis confirmed a high correlation in dimension measurements between the 3D-printed models and segmented images. Furthermore, the accuracy of a 3D-printed femoral pseudoaneurysm model was further tested through the simulation of a superficial femoral artery pseudoaneurysm coiling procedure using the Philips Azurion7 in the angiography room. Conclusions: 3D printing is a reliable technique for producing a high accuracy 3D anatomical model that closely resemble a patient’s anatomy based on CT images. Additionally, 3D printing is a feasible and viable option for use in endovascular training and medical education. In general, 3D printing is an encouraging technology with diverse possibilities in medicine, including surgical planning, medical education, and medical device advancement.

30 October 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SHShao Min Huang
Shao Min Huang
YYYu-Hsuan Yeh
Yu-Hsuan Yeh
Cheuk-Kwan SunCheuk-Kwan Sun
Cheuk-Kwan Sun
HCHsuan-We Chu
Hsuan-We Chu
Background: This study compared the accuracy of diagnosing left ventricular diastolic dysfunction (DD) between emergency physician (EP)-performed focused cardiac ultrasound (FCU) and cardiologist-interpreted reference standards in adult patients presenting to the emergency department (ED) with suspected acute heart failure (HF). Methods: PubMed, Embase, and the Cochrane Central Register of Controlled Trials were systematically searched for studies focusing on adult ED patients with symptoms of acute HF that compared the accuracy of DD diagnosis between EP-performed FCU and reference standards including cardiologist-reviewed FCU clips, formal transthoracic echocardiography, or invasive hemodynamics without language/date restrictions. Results: Meta-analysis of four eligible observational studies (327 patients enrolled; 298 analyzed) demonstrate excellent sensitivity of EP-performed FCU compared with the standards (94%, 95% CI: 87 to 97%) but moderate specificity (59%, 95% CI: 42 to 74%) in diagnosing DD patients with suspected acute HF. Three of the four studies showed a high risk of overall bias. Conclusions: EP-performed FCU exhibited excellent sensitivity and low negative likelihood ratios, supporting its use as an effective initial triage tool for ruling out DD in ED patients with suspected acute HF. However, its moderate specificity and limited positive likelihood ratios hamper its standalone use as a definitive diagnostic modality for ruling in DD (PROSPERO: CRD420251046794).