Sheta Mohamed Sheta Mohamed

Dr. Sheta Mohamed Sheta Mohamed

National Research Centre, Giza, Al Jīzah, Egypt
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DODiaa I. Osman
Diaa I. Osman
SESaid M. El-Sheikh
Said M. El-Sheikh
SMSheta Mohamed Sheta Mohamed
Sheta Mohamed Sheta Mohamed
OAOmnia I. Ali
Omnia I. Ali
ASAliaa M. Salem
Aliaa M. Salem
SSsherif Shawky
sherif Shawky

15 March 2018 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
SMSheta Mohamed Sheta Mohamed
Sheta Mohamed Sheta Mohamed
SESaid El-Sheikh
Said El-Sheikh
MAMokhles M. Abd-Elzaher
Mokhles M. Abd-Elzaher
Novel copper metal organic framework nanoparticles Cu-MOF-NPs (C1) were prepared via two simple alternative methods and confirmed by analytical characterization using mass, IR, Raman, XRD spectrum, HR-TEM and TGA-DSC. Mass spectroscopy revealed the molecular ion peak at 647 m/z for the monomeric unit structure n[Cu(AIP)2(PIY)(H2O)2]·4H2O, the presence of which was further supported by mass fragmentation. The Raman spectrum revealed two separate peaks corresponding to D and G bands of carbon in the structure of C1. Moreover, TGA-DSC showed the presence of CuO. XRD data were typically consistent with Raman and TGA-DSC data. In addition, HR-TEM revealed that the morphology of the C1 nanoparticles is uniform with well-distributed elliptical/spherical particles with a size range from 7 to 19 nm. The spectrophotometric and biological activity studies based on Cu-MOF-NPs were analyzed. The results indicated that Cu-MOF-NPs (C1) were successfully used as biosensors for the assessment of the triiodothyronine hormone (T3). The calibration plot was achieved over the concentration range of 40.0–100.0 ng dl−1 T3 with limits of detection (LOD) and quantitation (LOQ) of 1.46 and 4.85 ng dl−1, respectively, and a correlation coefficient (r) of 0.973. Moreover, the Cu-MOF-NPs (C1) show more enhanced biological activity against various pathogens (five strains of bacteria: Gram positive and Gram negative) when compared to an antibacterial agent and the effectiveness of Cu-MOF-NPs increases with increasing particle dose. The interactions of MOF-NPs (C1) with the biological targets were studied.

21 August 2023 in RSC Advances
Verified
Journal Article
Open access
PDF file
SMSheta Mohamed Sheta Mohamed
Sheta Mohamed Sheta Mohamed
MHMohamed A. Hamouda
Mohamed A. Hamouda
OAOmnia I. Ali
Omnia I. Ali
AKA. T. Kandil
A. T. Kandil
RSReda R. Sheha
Reda R. Sheha
SESaid El-Sheikh
Said El-Sheikh
The nuclear industry is rapidly developing and the effective management of nuclear waste and monitoring the nuclear fuel cycle are crucial.

1 June 2020 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
SMSheta Mohamed Sheta Mohamed
Sheta Mohamed Sheta Mohamed
SESaid El-Sheikh
Said El-Sheikh
DODiaa I. Osman
Diaa I. Osman
ASAliaa M. Salem
Aliaa M. Salem
OAOmnia I. Ali
Omnia I. Ali
Dionysios (Dion) DionysiouDionysios (Dion) Dionysiou
Dionysios (Dion) Dionysiou
Hepatitis-C virus ribonucleic acid (HCV-RNA) recognition and quantification based on real-time polymerase chain reaction (RT-PCR) is key to infection control, management, and response to treatment due to its specificity, sensitivity, and quantification capabilities. However, the high cost, time requirements, and need for sophisticated laboratory infrastructure have limited the use of this method in rapid screening, blood banks, and point-of-care testing (POCT). In this work, a novel label-free electrochemical biosensor constructed using a polyaniline@nickel metal–organic framework (Ni-MOF) nanocomposite was developed for direct detection of unamplified HCV nucleic acid. A robust biosensor was fabricated using smooth layer-by-layer deposition of the polyaniline@Ni-MOF nanocomposite, deoxyribonucleic acid (DNA) probe, and bovine serum albumin (BSA) onto a glassy carbon electrode (GCE) and was subsequently monitored real-time via cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The sensitivity and specificity of the newly developed biosensor were specifically examined using the EIS approach. The results revealed that the novel biosensor is highly efficient in quantitative sensing of the HCV target in the presence of nonspecific nucleic acids over the range of 1 fM–100 nM with a detection limit of 0.75 fM (at a S/N ratio of 3). To the best of the authors’ knowledge, the proposed biosensor is superior to other MOF platforms. These research findings are expected to have a positive influence on the quantitative detection of HCV RNA and other nucleic acids by offering exceptional accuracy and cost effectiveness, especially in low resource countries. Moreover, this biosensor could be simply adopted for full automation and used in point-of-care testing.

18 July 2022 in Journal of Materials Research
Verified
Journal Article
Open access
PDF file
SMSheta Mohamed Sheta Mohamed
Sheta Mohamed Sheta Mohamed
SSSalem R. Salem
Salem R. Salem
SESaid El-Sheikh
Said El-Sheikh
Recently infectious diseases and increasing microbial drug-resistant have caused many humorless health problems. To fill knowledge gaps and guide strategies at all levels for antimicrobials which represent a challenge and an urgent need. For these reasons, our target is developing a new effective antimicrobial drug with extended action time, multi-antimicrobial agents, low toxicity, and safe strategies. Metal–organic frameworks are promising materials for antimicrobial agents. Herein, a novel affordable Fe(III)-MOF was simply prepared via a reflux method. FE-SEM images showed an octahedral structure with sharp edges with high crystallinity and purity of Fe(III)-MOF. Under optimum conditions, the Fe(III)-MOF showed excellent antimicrobial efficiency against ± bacteria, fungus, and yeast with an inhibition zone ranging between 40–46 and 22–24 mm at a concentration of 50 and 25 μg/mL Fe(III)-MOF, respectively. As well, the mechanism of interaction is also well studied. The results open the door for the use of prepared materials as an effective and efficient antimicrobial agent.Graphical abstract