As climate change in the Nordic region brings an increase in extreme precipitation events, blue-green roofs have emerged as a solution for stormwater management, hereafter referred to as “blue-green roofs”. The addition of blue-green layers on a conventional compact roof represents several multi-disciplinary technical challenges and quality risks that must be managed. This paper aims to list and address the key building technical challenges associated with blue-green roofs and to present a framework for managing these risks. Literature and document studies as well as qualitative interviews and expert meetings have been conducted to collect research data on defects in blue-green roofs and causes thereof. A list of nine key challenges has been extracted along with recommendations on how to address them. The recommendations are structured around a framework developed for practical use in building projects. For ease of use, the nine key challenges are presented on a general level, with references to detailed recommendations. The framework is intended to be used to reduce the building technical risks of blue-green roofs, by addressing the most important quality risk elements.
Building façades must endure severe climatic exposure throughout their lifetimes. To prevent damage and expensive repairs, ageing tests are used in durability assessments. The NT Build 495 describes an artificial ageing procedure to address building material and component resistance to ultraviolet (UV) light, heat, water, and frost using a climate simulator. The test has been used for decades to investigate exterior surface materials and façade products but has only recently been adopted for multi-layered systems. This study investigates moisture accumulation in a façade system for retrofitting based on concrete and thermal insulation. Hygrothermal simulations of the façade system subjected to ageing were conducted. Moisture accumulation was considered theoretically for the current test procedure and compared to a modified setup in which the interior climate was controlled at 21 °C. Physical measurements were performed in the climate simulator to determine the boundary conditions. Results showed that moisture accumulation in the thermal insulation was largely affected by the type of concrete, that applying a water-repellent surface treatment reduced moisture accumulation, and that the current setup resulted in less moisture accumulation compared to the modified setup. The latter implicates accelerated degradation with the modified setup.
A wave of energy efficiency-focused activity has spread across Europe in recent years, with ambitious goals for improving the energy performance of existing buildings through various directives. Among these existing buildings, there are older structures with heritage-protected facades. Some of the protected facades consist of timber plank frame walls, which were common in Norway in the 19th and early 20th centuries. Internal insulation is an option for increasing the energy efficiency of such walls while preserving their protected facades. However, this approach alters the moisture performance of the wall and introduces a potential risk for mould growth, which must be assessed. To better understand the performance of these walls, the values of traditional types of building paper have been tested, as timber plank frame walls comprise vertical planks covered in building paper. In addition, the risk of mould growth in timber plank frame walls has been evaluated using the one-dimensional simulation tool WUFI® Pro by modelling the wall with internal retrofitting and varying input parameters. The types of building paper used have a wide range of vapour resistance values (diffusion-equivalent air layer thicknesses, values), which range from 0.008 m to 5.293 m. Adding 50 mm of interior insulation generally resulted in a low risk of mould growth, except in cases involving the use of a moisture-adaptive vapour barrier (MAVB). The MAVB did not result in an acceptable mould growth risk in any of the tested scenarios.