Silvano Vergura

Prof. Silvano Vergura

Dept. of Electrical and Information Engineering, Politecnico di Bari, Bari, Puglia, Italy
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Silvano VerguraSilvano Vergura
Silvano Vergura
GAGiuseppe Acciani
Giuseppe Acciani
VAVitantonio Amoruso
Vitantonio Amoruso
GPGiuseppe E. Patrono
Giuseppe E. Patrono
FVFrancesco Vacca
Francesco Vacca
This paper deals with the problem of supervising and monitoring a photovoltaic (PV) plant. First, an offline descriptive and inferential statistical procedure for evaluating the goodness of system performance is presented. Then, an online inferential algorithm for real-time monitoring and fault detection is introduced. The two methodologies utilize the energy output of inverters as input data and are valid for both Gaussian and non-normal distribution of data. The procedures have been tested on a real PV installation, and results are reported for the case of a grid-connected PV plant in Italy for which one PV module over 132 resulted in being badly connected.

28 April 2016 in Energies
Verified
Journal Article
Open access
PDF file
Silvano VerguraSilvano Vergura
Silvano Vergura
The paper proposes two mathematical models of a photo-voltaic (PV) cell—the complete model and the simplified model—which can be used also for modeling a PV module or a PV string under any environmental condition. Both of them are based on the well-known five-parameters model, while the approach allows to write a new descriptive equation, whose terms are functions of the information always available in the modern datasheet of a PV module’s manufacturer. This implies that no pre-processing of the datasheet parameters is needed to use the proposed model, whichever the solar irradiance and the cell/module temperature are. Moreover, these models are interpreted from a circuital point of view, providing the electrical circuits constituted only by basic electrical components. Particularly, in order to take into account the variability of the environment parameters, several variable resistors and voltage-controlled sources are used. The proposed models are tested with the datasheet parameters of commercial PV modules.

29 July 2011 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Silvano VerguraSilvano Vergura
Silvano Vergura
GAGiuseppe Acciani
Giuseppe Acciani
OFOttavio Falcone
Ottavio Falcone
The paper introduces the issue of the typical defects in photovoltaic (PV) cells and focuses the attention on three specific defects: linear edge shunt, hole, and conductive intrusion. These defects are modeled by means of finite-element method and implemented in Comsol Multiphysics environment to analyze the temperature distribution in the whole defected PV cell. All the three typologies of silicon-based PV cells are considered: monocrystalline, polycrystalline, and amorphous. Numerical issues (simulation times, degrees of freedom, mesh elements, and grid dependence analysis) are reported.

17 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jamel RiahiJamel Riahi
Jamel Riahi
Silvano VerguraSilvano Vergura
Silvano Vergura
DMDhafer Mezghani
Dhafer Mezghani
AMabdelkader mami
abdelkader mami
An agricultural greenhouse is a complex and Multi-Input Multi-Output MIMO system in which the internal parameters create a favorable microclimate for agricultural production. Temperature and internal humidity are two parameters that have a major impact on greenhouse yield. The objective of this study was to propose a simulated dynamic model in a MATLAB/Simulink environment for experimental validation. Moreover, a fuzzy controller was designed to manage a greenhouse indoor climate by means of an asynchronous motor for ventilation, heating, humidification, etc. An intelligent system to control these actuators for an optimal inside climate was implemented in the model. The dynamic model was validated by comparing the simulation results to experimental measurements. These results showed the effectiveness of the control strategy in regulating the greenhouse indoor climate. Finally, a photovoltaic generator was modeled, with the aim of reducing the costs of agricultural production. It feeds the asynchronous motor with a vector control optimized by fuzzy logic that drives a variable speed fan.

9 November 2020 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
Silvano VerguraSilvano Vergura
Silvano Vergura
The technological development of photovoltaic (PV) devices (perovskite-based or bifacial modules, etc.) has progressed considerably, but the commercial PV modules do not show analogous improvements and their efficiency is still low. Therefore, a diagnostic tool that can check the current operation of installed PV modules and their aging is important. In this scenario, an unmanned aerial vehicle (UAV), equipped with a camera, infrared (IR) camera, or both, represents a new avenue for the fast evaluation of faults for large or not easily accessible PV plants and the discovery of defective PV modules. Thermography has the advantage of not disconnecting the PV system during the inspection. Nevertheless, some specific parameters, such as the emissivity, the reflected temperature, and the resolution, are fixed during the acquisition, even if their values are dependent on the mutual position (distance and angle) between the IR camera and the PV modules. The movement of the UAV, equipped with an IR camera, modifies the position of the IR camera, and due to this movement, the values of the parameters can be incorrect during acquisition, which also results in errors in the radiometric map. In this article, we explore these issues and provide suggestions to ensure the correct acquisition and reading of thermal images of PV modules.

1 October 2017 in Solar Energy
Verified
Journal Article
Closed access
APA. Massi Pavan
A. Massi Pavan
Silvano VerguraSilvano Vergura
Silvano Vergura
AMAdel Mellit
Adel Mellit
VLV. Lughi
V. Lughi