The purpose of designing suitable grounding system is to ensure reliable power supply, safety of equipment and people working in electrical power operation and to limit voltage elevation to a minimum. In this paper, a series of tests were conducted to compare apparent soil resistivity of two different locations and how it is affected by depth of the soil and moisture content. The Wenner method was used to measure resistivity in both locations. The results obtained show how the soil resistivity varies with depth and spacing, which informs the design of earthing protection schemes for worst case scenarios. It was observed that the soil resistivity varies based on the type of soil and moisture content. The wet soil had lower resistivity than the dry soil. The proposed design shows that the number of earth electrodes required varies from 4 to 11 for wet to dry soil conditions respectively in Site-1, and 18 to 35 earth electrodes for wet to dry soil conditions respectively in Site-2. Thus, the number of electrodes required is higher for dry soil condition, because the soil resistivity is high.

1 January 2020
Verified
Conference Paper
Closed access
Sindisiwe MalandaSindisiwe Malanda
Sindisiwe Malanda
Innocent Ewean DavidsonInnocent Ewean Davidson
Innocent Ewean Davidson
GAGrain A. Adam
Grain A. Adam
Multi-terminal HVDC grid is one of the promising solutions of the electrical power network configuration that ensures the reliability of power supply and economy of the power generated from numerous renewable sources. The benefits of using HVDC grids are the possibilities of trading energy in different AC systems and transporting large scale of power over long distances. This paper will be showing the importance of DC voltage control strategies in a multi-terminal VSC-HDVC system following a system disturbance caused by an asymmetrical three-phase fault. Conventional and Droop methods are the two control strategies that will be compared in this paper. MATLAB/Simulink software simulator will be used to evaluate the response of a DC grid when a three-phase to ground AC fault occurs. The results show that droop-controlled DC grids are highly reliable during abnormal operating conditions compared to the conventional method.