Adipose tissue and its regenerative products which are isolated with enzymatic or mechanical processing of the harvested fat have been studied in a wide range of degenerative diseases, including osteoarthritis of the knee and hip. Intra-articular injection of these products can provide symptomatic relief of pain and postpone surgery. However, their use in the treatment of thumb carpometacarpal joint (CMCJ) osteoarthritis is limited and just a few studies have been published on that topic. For this reason, a review of the literature was performed by a thorough search of eight terms using the Pubmed database. In total, seven human studies met the selection criteria, including case-control studies, case-series and one case report. In all studies, intra-articular injection of autologous fat in osteoarthritic thumb CMCJ provided reduction in pain and improvement in hand function. Grip and pinch strength showed variable results, from no change to significant improvement. Fat-processing techniques were based on centrifugation and mechanical homogenization but biological characterization of the injected cells was not performed in any study. Although the results are encouraging, a uniformly standardized method of fat processing and the conduction of randomized controlled trials in the future could better evaluate the effectiveness of this procedure for thumb CMCJ osteoarthritis.
Liquid drain unblockers, although meant to be used by professionals with protective equipment, are sometimes used in the household without any precautions. This could lead to severe chemical burns, as in the case we present with severe eyelid ectropion. This study aims to stress the need for preventive measures regarding the use of chemicals and for close observation and timely surgical intervention in chemical burn patients to prevent and limit disfigurement. A 45-year-old woman was injured while using an unblocker (90% sulfuric acid) at home. Accidentally, a quantity of the liquid was spilled on her face. She was initially examined in ophthalmology emergencies because of the obvious ocular involvement, and the cutaneous component was underestimated. On the third post-burn day, she was referred as an outpatient to our clinic, and because of the soft consistency and patchy pattern of the burn, she was asked to revisit in a week. Unfortunately, she reappeared two months post-burn with severe ectropion of all four eyelids and a high risk of corneal abrasion, desiccation, and further damage to the already injured left eye as well as the right eye. She underwent three operations in six months and a fourth 15 months after the accident, with the release of the scarred eyelids with full-thickness skin grafts, Z-plasties, and V-Y plasties. After four operations and sessions of triamcinolone acetonide intralesional injection, the patient has a satisfactory eyelid position and function with adequate closure and scar maturation. Domestic use of strong industrial chemicals is dangerous, and public education for prevention is urgently needed. On the other hand, it is mandatory to follow up very closely with chemical burn patients to prevent severe sequelae, especially in the delicate and contraction-prone periocular and perioral areas. Reconstruction, in these cases, is a complex task. Often, several surgeries are needed to restore acceptable function and appearance. Burn disfigurement and self-stigma will follow the patients to some extent throughout their lives.
Background: Coagulopathy in severe burn injury is associated with complications and mortality. Methods: We compared 3 tests (EXTEM, INTEM, FIBTEM) of rotational thromboelastometry (ROTEM), a viscoelastic coagulation assay (VCA), with conventional coagulation assays (CCAs), fibrinogen, d-dimers and coagulation factors during the five post-burn days in survivors and non-survivors with severe burn injury, in order to correlate the results with burn coagulopathy and prognosis. Results: Seventeen survivors and ten non-survivors, with mean total burn surface area of 33.78% were included. CCAs measurements were abnormal, but unable to detect coagulopathy. At day 2, D-dimers and fibrinogen levels were statistically augmented for non-survivors. Regarding VCAs, FIBTEM MCF increased for non-survivors at day 2 and remained increased for the whole post-burn period. Furthermore, FIBTEM A10 and A20 at day 2 and EXTEM A10, EXTEM A20, EXTEM MCF, and EXTEM CFT at day 5 took abnormal values for the same group (p < 0.05). These changes were underlined through abnormal measurements of coagulation factors. Conclusions:CCAs are poor indicators of coagulation status in burn injury, whereas VCAs are more sensitive markers, demonstrating coagulopathy and patients at greater risk of mortality.
The alterations of coagulation status in patients with Severe Burn Injury are associated with serious complications, increased morbidity and mortality. This study aims to compare Rotational Thromboelastometry(ROTEM)–a Viscoelastic Coagulation Assays(VCAs) with Conventional Coagulation Assays(CCAs) including Prothrombin time(PT), Activated Partial Thromboplastin time(aPTT), International normalized ratio(INR), Complete Blood Count(CBC) and Coagulation Factors during the early five post- burn days in Survivors and Non- Survivors with Severe Burn Injury in order to correlate these results with Burn Coagulopathy and Prognosis. Seventeen Sur-vivors and ten Non- Survivors, with a mean Total Burn Surface Area(TBSA) of 33,78% were in-cluded in our study. Even though CCAs measurements were abnormal, they were unable to detect overall burn patients’ coagulopathy. On the contrary, VCAs from day 2 to day 5 took pathological values, especially for Non- survivors. Those changes were underlined through pathological values of Coagulation Factors. As a result, CCAs were considered poor indicators of coagulation status in burn injury, whereas VCAs were more accurate in demonstrating coagulation alterations from the early post- burn period and detecting patients in greater risk of mortality. These advantages of VCAs could be used for timely intervention in high risk patients and for the guidance of blood product transfusions.
Introduction: Patients with major burn injuries are highly susceptible to hypothermia due to extensive skin loss, aggressive fluid resuscitation, repeated surgical procedures, and exposure during wound care. Hypothermia is associated with coagulation disorders, increased blood loss, impaired immune response, prolonged hospitalization, and increased mortality. When conventional warming strategies fail, intravascular temperature management systems may be employed, although they carry risks inherent to central venous catheters. Case Report: We report the case of a 26-year-old male with 66% total body surface area flame burns and inhalational injury, admitted to the Burns Intensive Care Unit with persistent hypothermia despite standard warming measures. An intravascular temperature management catheter was inserted via the femoral vein and successfully restored normothermia. Due to clinical instability, the catheter remained in situ beyond the recommended duration. During attempted catheter removal, significant resistance was encountered, raising concern for mechanical malfunction. Imaging confirmed catheter entrapment without fracture. Multidisciplinary management involving vascular surgery and interventional radiology enabled successful removal using endovascular snare techniques. A detached balloon fragment was identified and secured with venous stenting. Conclusions: This report describes the first documented case of complicated removal of an intravascular warming catheter due to balloon detachment in burn patients. Physicians using these devices should be aware of this possible complication and be prepared for its management.
Introduction: Patients with major burn injuries are highly susceptible to hypothermia due to extensive skin loss, aggressive fluid resuscitation, repeated surgical procedures, and exposure during wound care. Hypothermia is associated with coagulation disorders, increased blood loss, impaired immune response, prolonged hospitalization, and increased mortality. When conventional warming strategies fail, intravascular temperature management systems may be employed, although they carry risks inherent to central venous catheters. Case Report: We report the case of a 26-year-old male with 66% total body surface area flame burns and inhalational injury, admitted to the Burns Intensive Care Unit with persistent hypothermia despite standard warming measures. An intravascular temperature management catheter was inserted via the femoral vein and successfully restored normothermia. Due to clinical instability, the catheter remained in situ beyond the recommended duration. During attempted catheter removal, significant resistance was encountered, raising concern for mechanical malfunction. Imaging confirmed catheter entrapment without fracture. Multidisciplinary management involving vascular surgery and interventional radiology enabled successful removal using endovascular snare techniques. A detached balloon fragment was identified and secured with venous stenting. Conclusions: This report describes the first documented case of complicated removal of an intravascular warming catheter due to balloon detachment in burn patients. Physicians using these devices should be aware of this possible complication and be prepared for its management.