In this paper, an efficient adaptive energy management strategy (EMS) is presented for a hybrid energy storage system (HESS) application to compensate power fluctuation. The HESS consists of a battery and super-capacitor, which are integrated into the DC grid using a modified triple active bridge converter (m-TAB). The conventional EMS uses a low pass filter (LPF) to distribute high and low-frequency components of power. However, the time constant of the LPF is fixed throughout the process, which discharges the battery at the same rate even near the low state of charge (SOC) region. This increases the degradation rate of the battery. The proposed EMS employs an adaptive time constant LPF-based power allocation method to distribute the total power between the energy storage devices. The adaptive feature of the EMS changes the power distribution ratio dynamically to increase the utilization of the super-capacitor and battery operation time, thereby enhancing the life cycle. The proposed EMS is simulated in MATLAB/SIMULINK platform with the m-TAB converter, and the results are compared with the conventional EMS to prove its superiority. The system is also tested on an experimental prototype of 500 W for different test cases, and the outcomes are presented to support the proposed EMS.
16 April 2020 in IEEE Transactions on Industry Applications
In this paper, a single source transformer-less boost multilevel inverter topology is proposed. The salient features of the proposed topology include voltage boost capability, reduced number of switches, and requirement of a single dc voltage source, which in turn reduces the overall cost and complexity. The proposed topology comprises a conventional boost converter and a diode-capacitor voltage multiplier circuit (VMC). The capacitors' voltages of the VMC are self-balanced, which eliminates the requirement of any auxiliary circuit for capacitor voltage balancing. Moreover, due to the input inductor, it has less input current ripple and able to provide variable fractional voltage gain, which is a key requirement for maximum power point tracking (MPPT) in photovoltaic applications. In order to get an optimal harmonic profile of the output ac voltage, a fundamental frequency switching technique named as the fundamental frequency sine quantization method (FFSQM) is adopted for the generation of the switching signals. Finally, a hardware prototype of the proposed 11-level boost inverter is developed and the MATLAB/Simulink results along with the experimental results are presented to validate the efficacy of the proposed converter.
11 January 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This article presents a time-domain optimization technique for minimizing harmonic content in the output voltage and current waveforms of a single-phase multilevel inverter (MLI) topology with an arbitrary $RL$ -load. The effect of the modulation index and the load parameters variation on the harmonic content of load voltage and current have also been analyzed. A single-phase 21-level MLI is developed to verify the proposed switching technique. The total harmonic distortion (THD) of the current and voltage in the time-domain is considered as the optimization constraint to compute the inverter’s optimal switching angles. In addition, the load time constant has also been considered during optimization problem formulation, which enables superior inverter performance in terms of lower THD in the output response. The detailed theoretical, simulation, and experimental analysis are carried out on the presented topology to verify the proposed switching technique’s performance.
In this article, a multiresonant proportional-resonant (PR) controller-based current controller is presented for a single-phase multilevel inverter topology, enabling grid-current injection into the distribution grid at unity power factor. The multiresonant PR-controller compensates third and fifth harmonic components to improve the harmonic spectrum of the grid injected current. Moreover, to reduce the switching losses in the power electronics converter, the nearest level modulation technique has been adopted, increasing overall efficiency. Furthermore, a modified multilevel inverter has been presented for grid integration, which requires a reduced number of switching components and isolated dc sources. In addition, system stability and sensitivity analysis are presented to evaluate the performance of the controller. The proposed scheme reduces the harmonic content in the grid current and the steady-state error in the grid injected power. Furthermore, the multiresonant PR-controller and PI-controller performance is verified in terms of steady-state error and total harmonic distortion in the grid current. An experimental prototype of the 21-level modified multilevel inverter-based grid-connected system has been developed to validate the claim.
16 August 2019 in International Transactions on Electrical Energy Systems