This paper focuses on the finite physical dimensions thermodynamics (FPDT)-based design of combined endoreversible power and refrigeration cycles (CCHP). Four operating schemes were analyzed, one for the summer season and three for the winter season. These basic CCHP cycles should define the reference ones, having the maximum possible energy and exergy efficiencies considering real restrictive conditions. The FPDT design is an entropic approach because it defines and uses the dependences between the reference entropy and the control operational parameters characterizing the external energy interactions of CCHP subsystems. The FPDT introduces a generalization of CCHP systems design, due to the particular influences of entropy variations of the working fluids substituted with influences of four operational finite dimensions control parameters, i.e., two mean log temperature differences between the working fluids and external heat sources and two dimensionless thermal conductance inventories. Two useful energy interactions, power and cooling rate, were used as operational restrictive conditions. It was assumed that there are consumers required for the supplied heating rates depending on the energy operating scheme. The FPDT modeling evaluates main thermodynamic and heat transfer performances. The FPDT model presented in this paper is a general one, applicable to all endoreversible trigeneration cycles.
This paper develops simplifying entropic models of irreversible closed cycles. The entropic models involve the irreversible connections between external and internal main operational parameters with finite physical dimensions. The external parameters are the mean temperatures of external heat reservoirs, the heat transfers thermal conductance, and the heat transfer mean log temperatures differences. The internal involved parameters are the reference entropy of the cycle and the internal irreversibility number. The cycle’s design might use four possible operational constraints in order to find out the reference entropy. The internal irreversibility number allows the evaluation of the reversible heat output function of the reversible heat input. Thus the cycle entropy balance equation to design the trigeneration cycles only through external operational parameters might be involved. In designing trigeneration systems, they must know the requirements of all consumers of the useful energies delivered by the trigeneration system. The conclusions emphasize the complexity in designing and/or optimizing the irreversible trigeneration systems.
The paper presents a comparative thermodynamic analysis of irreversible closed Brayton engine cycles for two working fluids and for four imposed thermodynamic parameters. The chosen fluids are the air and the carbon dioxide. The four imposed thermodynamic constraints are the specific entropy variation during the heating process, the specific input heat, the specific output power and the energy efficiency. The irreversibility is quantified by the isentropic efficiencies of compressor and of gas turbine, and by the pressure drops coefficient during the heating and cooling processes of the working fluid. Each imposed thermodynamic parameter allowed to evaluate all corresponding cycle parameters, i.e. temperatures and pressures, and operational parameters, i.e. energy transfer values, function of pressure compression ratio and irreversibility magnitude. The thermodynamic analysis compares the selected results for the two working fluids.
The paper develops generalizing entropic approaches of irreversible closed cycles. The mathematical models of the irreversible engines (basic, with internal regeneration of the heat, cogeneration units) and of the refrigeration cycles were applied to four possible operating irreversible trigeneration cycles. The models involve the reference entropy, the number of internal irreversibility, the thermal conductance inventory, the proper temperatures of external heat reservoirs unifying the first law of thermodynamics and the linear heat transfer law, the mean log temperature differences, and four possible operational constraints, i.e., constant heat input, constant power, constant energy efficiency and constant reference entropy. The reference entropy is always the entropy variation rate of the working fluid during the reversible heat input process. The amount of internal irreversibility allows the evaluation of the heat output via the ratio of overall internal irreversible entropy generation and the reference entropy. The operational constraints allow the replacement of the reference entropy function of the finite physical dimension parameters, i.e., mean log temperature differences, thermal conductance inventory, and the proper external heat reservoir temperatures. The paper presents initially the number of internal irreversibility and the energy efficiency equations for engine and refrigeration cycles. At the limit, i.e., endoreversibility, we can re-obtain the endoreversible energy efficiency equation. The second part develops the influences between the imposed operational constraint and the finite physical dimensions parameters for the basic irreversible cycle. The third part is applying the mathematical models to four possible standalone trigeneration cycles. It was assumed that there are the required consumers of the all useful heat delivered by the trigeneration system. The design of trigeneration system must know the ratio of refrigeration rate to power, e.g., engine shaft power or useful power delivered directly to power consumers. The final discussions and conclusions emphasize the novelties and the complexity of interconnected irreversible trigeneration systems design/optimization.
The paper presents a useful engineering model for the design of preliminary hybrid rocket engines. This model involves the experimentally obtained equation regarding the speed of the burning interface between solid fuel and gaseous phase, called the regression rate. This regression rate characterizes the mass rate of the burning fuel and additionally the mass rate of the oxidizer through the imposed ratio of these mass rates during combustion. The preliminary design is applied to combustion using pure HTPB and gaseous oxygen and was developed for three cases, constant regression rate, constant oxygen mass flow rate and constant O/F (ratio of mass rates of oxygen and of fuel). The design evaluates the initial fuel port geometry, the initial mass of fuel and oxygen, the combustion time, the thrust at sea level, and the time-dependent functions of regression rate, of fuel and oxygen mass rates, and of thrust. It was assumed that the regression rate formula applies at any time of combustion. These evaluations can also be applied for other fuel/oxygen couples by knowing the correct formula for the regression rate.