Stephan Harm

Dr. Stephan Harm

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2019 in Blood Purification
Verified
Journal Article
Closed access
PDF file
Stephan HarmStephan Harm
Stephan Harm
CSClaudia Schildböck
Claudia Schildböck
Jens HartmannJens Hartmann
Jens Hartmann
Background/Aims: Cytokines are among the main target substances that have to be removed effectively in order to improve the patient’s health status in the treatment of sepsis, septic shock, and liver diseases. Although there are various medical devices commercially available, the success of their clinical use is limited. The aim of this in vitro study was to compare 3 different medical devices with respect to their clearance for the cytokines interleukin-6 (IL-6), IL-8, IL-1β, and tumor necrosis factor alpha. The medical devices that were tested are the whole blood adsorbent CytoSorb, the high cutoff filter EMiC2, and the hemofilter HemofeelCH 1.8. Methods: The study was carried out on the multiFiltrate machine with 1 L human plasma for 8 h. Samples for cytokine quantification were taken at defined time points from the plasma pool. Each experiment was conducted in triplicates, and clearance was calculated for all tested cytokines. Results: All 3 medical devices showed good cytokine removal. The highest clearance for all cytokines was achieved by hemoperfusion with Cytosorb. IL-8 and IL-6 clearance were higher with Hemofeel (continuous venovenous hemodiafiltration) than with EMiC2 (continuous venovenous hemodialysis) because the polymethyl methacrylate (PMMA)-based membrane Hemofeel is able to remove these 2 cytokines by adsorption. Protein and albumin loss was highest withCytosorb and lowest with EMiC2. Conclusion: The mechanisms of cytokine removal by blood purification include convection, diffusion, and adsorption. PMMA-based filters are able to combine all 3 mechanisms for certain cytokines. Cytosorb showed the best adsorption kinetics, while dialysis with polystyrene-based membranes offers the best biocompatibility because they do not show any unspecific adsorption of other plasma components.

18 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Stephan HarmStephan Harm
Stephan Harm
CSClaudia Schildböck
Claudia Schildböck
KSKarin Strobl
Karin Strobl
JHJens Hartmann
Jens Hartmann
Endotoxin neutralization, caused by plasma components, makes it difficult to detect endotoxins in human blood. In this study, we investigated which factors influence the recovery of endotoxins using limulus ameobocyte lysate (LAL)-based assays. The individual factors that were examined in more detail were lipoprotein content, type of blood anticoagulation, kinetics and serum levels of divalent cations. Furthermore, it was investigated whether there is a direct correlation between LAL activity and monocyte activation. We could show that polyanionic heparin increases endotoxin recovery in blood, while citrate anticoagulation promotes endotoxin neutralization. Furthermore, we could show that the endotoxin activity in human plasma and serum decreases strongly over time. Time-dependent endotoxin neutralization reaches its maximum after 4–6 h incubation. By means of filtration tests we could determine that endotoxins in the plasma bind to lipoproteins but do not influence their activity. Comparative measurements have shown that high LAL activity of endotoxins in plasma simultaneously possesses high monocyte activating properties in whole blood. For the maximum recovery of endotoxins in human blood the physiological calcium and magnesium concentrations are sufficient. In this study, it was shown that the endotoxin neutralizing plasma components have a molecular weight similar to β2-microglobulin (11.7 kDa). For the exact identification of the endotoxin neutralizing plasma components, which caused a modulation of the immunostimulating endotoxin activity, further investigations have to be carried out in the future.

23 September 2014 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
Stephan HarmStephan Harm
Stephan Harm
DFDieter Falkenhagen
Dieter Falkenhagen
Jens HartmannJens Hartmann
Jens Hartmann
Purpose: Extracorporeal blood purification systems based on combined membrane/adsorption technologies are used in acute liver failure to replace detoxification as well as to remove inflammatory mediators in sepsis patients. In addition to coating and chemical modification of the surface, pore size significantly controls the selectivity of adsorption materials. Methods: This study addresses the adsorption of albumin bound liver toxins, cytokines, and representative plasma compounds on three adsorbents which differ only in pore size distribution. All three adsorbents are based on hydrophobic poly(styrene-divinylbenzene) copolymer matrices and have mean pore sizes of 15, 30, and 100 nm. Results: The pores of adsorbents act as molecular sieves and prevent the entry of molecules that are larger than their molecular cut-off. The results of this study reveal that adsorbents based on styrene-divinylbenzene polymers with 15 nm pores are suitable for cytokine removal, and the same adsorbents with 30-40 nm pores are the best choice for the removal of albumin-bound toxins in the case of liver failure. Adsorbents with very large pores lack selectivity which leads to uncontrolled adsorption of all plasma proteins. Therefore, hydrophobic adsorbents with large pores offer inadequate plasma compatibility and do not fulfill the requirements for blood purification. Conclusions: Biocompatibility and efficiency of adsorbents used for blood purification can improved by fine tuning of adsorbent surface pore distributions.

1 March 2014 in Environmental Processes
Verified
Journal Article
Closed access
PDF file
Jens HartmannJens Hartmann
Jens Hartmann
RBReinhard Beyer
Reinhard Beyer
Stephan HarmStephan Harm
Stephan Harm

Verified
Journal Article
Open access
PDF file
Stephan HarmStephan Harm
Stephan Harm
KLKarl Lohner
Karl Lohner
UFUte Fichtinger
Ute Fichtinger
CSClaudia Schildböck
Claudia Schildböck
JZJennifer Zottl
Jennifer Zottl
Jens HartmannJens Hartmann
Jens Hartmann
Acylation of antimicrobial peptides mimics the structure of the natural lipopeptide polymyxin B, and increases antimicrobial and endotoxin-neutralizing activities. In this study, the antimicrobial properties of lactoferrin-based LF11 peptides as well as blood compatibility as a function of acyl chain length were investigated. Beyond the classical hemolysis test, the biocompatibility was determined with human leukocytes and platelets, and the influence of antimicrobial peptides (AMPs) on the plasmatic coagulation and the complement system was investigated. The results of this study show that the acylation of cationic peptides significantly reduces blood tolerance. With increasing acyl chain length, the cytotoxicity of LF11 peptides to human blood cells also increased. This study also shows that acylated cationic antimicrobial peptides are inactivated by the presence of heparin. In addition, it could be shown that the immobilization of LF11 peptides leads to a loss of their antimicrobial properties.

1 March 2014 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
Stephan HarmStephan Harm
Stephan Harm
DFDieter Falkenhagen
Dieter Falkenhagen
Jens HartmannJens Hartmann
Jens Hartmann
Introduction: Lipopolysaccharides (LPS) are extremely strong stimulators of inflammatory reactions, act at very low concentrations, and are involved in the pathogenesis of sepsis and septic shock. Because of its toxicity, the efficient removal of endotoxin from patients’ blood is very important in clinical medicine. The purpose of this study was to determine the endotoxin adsorption capacities of commercial endotoxin adsorbers for endotoxin removal in buffer solution, protein solution, serum and heparinized plasma; some of these were also characterized in whole blood. The tested LPS adsorbers were Toraymyxin® PMX-20R, Alteco® LPS Adsorber, DEAE-Sepharose, Polymyxin B-Agarose, and EndoTrap® red. Methods: The adsorber materials were tested in buffer and protein solutions spiked with fluorescently labeled LPS (100 ng/ml). Additionally, batch tests with LPS-spiked serum, heparinized plasma and whole blood were performed with an LPS concentration of 5 ng/ml. Additionally, the washing solutions of the two tested Polymyxin B (PMB)-based adsorbers were analyzed for PMB release to determine if the resulting LPS inactivation was caused by PMB leakage. Results: The results show that DEAE-Sepharose was most effective in LPS adsorption. Of the other tested endotoxin removal materials, only the PMB-based adsorbers were able to reduce the LPS activity. However, we were able to show that the reduction in LPS activity was caused by desorbed PMB, which inactivates endotoxins. Conclusions: None of the adsorbents that were tested in this study showed promising results for potential use in extracorporeal blood purification.