Stjepan Strelec

Prof. Dr. Stjepan Strelec

University of Zagreb
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2020 in Geosciences
Verified
Journal Article
Open access
PDF file
Jasmin JugJasmin Jug
Jasmin Jug
Kristijan GrabarKristijan Grabar
Kristijan Grabar
Stjepan StrelecStjepan Strelec
Stjepan Strelec
FDFilip Dodigovic
Filip Dodigovic
A site located on the island of Brač is known in history for world-famous architectural stone and stone mining, dating all the way back to ancient Greek and Roman times. The most famous building constructed from the stone from Brač is the Diocletian Cesar Palace in the town Split. Prospective new locations for quarries are still required because the demand for the stone from the island is still high. This paper presents a review of undertaken geophysical investigations, as well as engineering geologic site prospection, with the purpose of determining if the rock mass quality is suitable for the mining of massive blocks needed for an architectural purpose—dimension stones. Several surface noninvasive geophysical methods were applied on the site, comprising of two seismic methods, multichannel analysis of surface waves (MASW) and shallow refraction seismic (SRS) electrical methods of electrical resistivity tomography (ERT), as well as electromagnetic exploration with ground penetrating radar (GPR). Results of geophysical investigations were compared to the engineering geologic prospection results, as well to the visible rock mass structure and observed discontinuities on the neighboring existing open mine quarry. Rock mass was classified into three categories according to its suitability for dimension stone exploitation. Each category is defined by compressional and shear seismic velocities as well as electrical resistivity. It has been found that even small changes in moisture content within the large monolithic rock mass can influence measured values of electrical resistivity. In the investigated area, dimension stone quarrying is advisable if the rock mass has values of resistivity higher than 3000 Ωm, as well as compressional seismic velocities higher than 3000 m/s and shear wave velocities higher than 1500 m/s. Georadar was found to be a good tool for the visual determination of fissured systems, and was used to confirm findings from other geophysical methods.

25 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Kristijan GrabarKristijan Grabar
Kristijan Grabar
Stjepan StrelecStjepan Strelec
Stjepan Strelec
MŠMiljenko Špiranec
Miljenko Špiranec
FDFilip Dodigovic
Filip Dodigovic
This paper was prepared based on in situ measurements carried out by the authors using the CPTu and DMT static penetration probes. The list of study sites includes seven specific locations in the northern parts of Croatia and one study site on the southern border of the country. The sites were selected based on the criterion of soil type, which falls into the category of soft to firm, slightly over-consolidated silty clays and silty sands. Intermediate soils are prevalent in the wider region, and most engineers deal with them in their everyday practice. For this reason, local characterization is of most importance for engineering purposes. In this investigation, results of in-situ tests are compared in order to validate the quality of the constrained modulus obtained from a CPT test to the one obtained by a DMT flat dilatometer. A comparison was made between the CPT test cone resistance Qt1 and two DMT parameters—normalized modulus ED/σ′v0 and horizontal stress index KD. Dependencies were analyzed for the main soil groups and intermediate data groups. Clay soils were divided into two subgroups based on the identification parameter ID, while silty soils were analyzed in three subgroups. The results for each subgroup differed significantly, and the analyses showed deviations from published values, especially for the intermediate soil groups. The usefulness of the application is demonstrated with examples at two sites, showing improvements over the most commonly used formula for the constrained modulus from the CPT test.

28 February 2024 in Geotechnics
Verified
Journal Article
Open access
PDF file
Jasmin JugJasmin Jug
Jasmin Jug
Kristijan GrabarKristijan Grabar
Kristijan Grabar
ABAnja Bek
Anja Bek
Stjepan StrelecStjepan Strelec
Stjepan Strelec
Climate change brings with it phenomena such as large amounts of rainfall in short periods. Infiltration of rainwater into clayey soils is a common trigger for shallow landslides on slopes. In this way, numerous shallow landslides occur in the area of northern Croatia, and a characteristic example is the landslide “Orehovčak”. To stop the sliding of the destabilized slope, it was necessary to solve the drainage of water that infiltrates the landslide body. For this purpose, detailed geotechnical investigations and monitoring were conducted. Many data were collected at the investigation site, especially soil characteristics and groundwater fluctuations. The surface soil on the slope consists of highly plastic clay, and the sliding surface was created in contact with the solid subsoil of marl, the depth of which varies positionally. The analyses confirmed that water is a slip trigger. To solve the problem, excavations and installation of deep drains were performed. The slope safety factor confirms landslide stabilization, whose calculated value after rehabilitation was Fs = 1.645. Inclinometer readings carried out after remediation show that slope slippage stopped. This confirms that the presented remediation method is very applicable to shallow landslides in northern Croatia and similar landslides around the world.

26 February 2024 in Geosciences
Verified
Journal Article
Open access
PDF file
Kristijan GrabarKristijan Grabar
Kristijan Grabar
Jasmin JugJasmin Jug
Jasmin Jug
ABAnja Bek
Anja Bek
Stjepan StrelecStjepan Strelec
Stjepan Strelec
The increasing occurrence of landslides worldwide causes many human casualties and huge socio-economic losses. Therefore, the fastest and most accurate characterisation of landslides is important. The objective of this study is to compare how well the flat dilatometer (DMT) test and the piezocone penetration (CPTU) test can find the depth of a sliding zone. Inclinometers were used to measure horizontal changes in the soil to ensure the depth of the sliding zone was correct. The coincidence of the results of in situ static probes, and the displacements of the inclinometers is a sure confirmation of the depth of the sliding zone. In the example of Bedekovčina and Kravarsko landslides, in situ static probes were used to obtain values of input parameters on the sliding zone for parametric sensitivity analysis of parameters. Sensitivity analysis was performed by plotting the relationship between the above parameters and the vertical effective stress σ′vo on the sliding zone. The sensitivity analysis of the parameters of 11 tested samples shows that for the parameters of the obtained DMT probe, a higher sensitivity of the parameters is obtained, closer to the values concerning the expected range, and a minor standard deviation. The parameter Kd obtained by dilatometer probing is the best indicator of the depth of the sliding zone. The literature value Kd = 1.8–2.0 on the sliding zone in this paper is extended to the range Kd = 1.8–2.5, and its detection sensitivity is influenced by over-consolidation in shallow soil layers. In general, the research results show that the dilatometer probe has an advantage over the piezocone penetrometer test for the needs of landslide characterisation.

24 September 2025 in Academia Engineering
Verified
Journal Article
Open access
PDF file
Ekrem BektaševićEkrem Bektašević
Ekrem Bektašević
Stjepan StrelecStjepan Strelec
Stjepan Strelec
NSNoris Sakić
Noris Sakić
KGKemal Gutic
Kemal Gutic
The application of multichannel surface wave analysis (MASW) has proven to be an effective method for non-invasive investigation of shallow geological structures, especially under complex conditions with heterogeneous layers and the presence of groundwater. In the technical stone quarry field in Čelina, MASW enabled precise soil characterization, identification of transition zones and anomalies, and determination of seismic resistance of layers based on the Vs30 parameter. The investigations confirmed the presence of a fault structure within the deposit, with the wider fault zone proving to be hydrogeologically significant, potentially acting as an aquifer. The geological composition of the carbonate terrain, characterized by lateral variability, required a conservative approach to the analysis based on the fundamental dispersion mode. The creation of a three-dimensional model from combined MASW profiles provided accurate spatial insight into the mechanical properties of the soil, facilitating engineering decision-making for future interventions. The results also indicated the need for further investigations, including the potential drilling of an exploration borehole in the fault zone to confirm the presence of an aquifer layer. MASW is confirmed as a reliable, economical, and practically applicable method for a wide range of engineering and hydrogeological studies. Its ability to quickly profile the soil makes it suitable for urban and inaccessible areas, and when combined with other geophysical methods, it can contribute to an integrated approach to subsurface analysis.

28 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Stjepan StrelecStjepan Strelec
Stjepan Strelec
Kristijan GrabarKristijan Grabar
Kristijan Grabar
Jasmin JugJasmin Jug
Jasmin Jug
Nikola KranjčićNikola Kranjčić
Nikola Kranjčić
The utilization of groundwater is becoming increasingly popular for heating and cooling buildings, as well as to regulate the temperature needs of industrial processes. Groundwater has excellent energy potential from various factors, of which environmental acceptability stands out, as groundwater is considered a source of renewable energy. Due to the water table depth below the surface, atmospheric conditions have a negligible effect on the temperature of groundwater, resulting only in minor annual temperature variations, thus also making groundwater a source of reliable renewable energy. This paper presents some aspects of the groundwater heat pump (GWHP) system’s design and addresses a particular problem on the influence of recharge temperature field as well as local utility lines on the pumping well water temperature. An example is given of a system designed for a production hall in the northern part of Croatia. Geological and hydrogeological conditions at the site are highly favourable regarding the groundwater temperature and aquifer parameters. For the needs of this research, precise electronic sensors with data loggers were installed inside the wells. Probe type GSR 120 NT manufactured by Eltratec, Slovenia, is capable of monitoring level, temperature, and electrical conductivity, including telemetric data transfer to the remote server. Mapping the obtained data revealed significant temperature breakthroughs from the recharge wells, as well as local temperature field deviation near the sanitary and precipitation drainage collectors. Utility installation seepage influence was differentiated by the increase in groundwater electrical conductivity measured at the pumping wells. Results show that not only distance between the wells, as the main parameter that affects the system, but also industrial utility lines can have an influence on thermal field breakthrough.