sukangkana talangkun

Dr. sukangkana talangkun

Khon Kaen University, Khon Kaen, Thailand
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
TLTeerawat Laonapakul
Teerawat Laonapakul
RSRatchawoot Sutthi
Ratchawoot Sutthi
PCPatamaporn Chaikool
Patamaporn Chaikool
STsukangkana talangkun
sukangkana talangkun
ABApichat Boonma
Apichat Boonma
PCPrinya Chindaprasirt
Prinya Chindaprasirt

23 July 2022 in Crystals
Verified
Journal Article
Open access
PDF file
PJPorawit Jiandon
Porawit Jiandon
STsukangkana talangkun
sukangkana talangkun
This research aimed to investigate the effects of bismuth (Bi) and phosphorus (P) addition on the microstructure and roughness of a B390 hypereutectic Al-Si alloy. Microstructural variation of as-cast alloys showed that P is an effective refiner of primary Si and its distribution, while Bi has the opposite effect. The liquidus temperature increased with greater amounts of P, resulting in a wider solidification range. The solidus temperature increased with Bi content, resulting in a shortened solidification range. The benefit of Bi on eutectic silicon was through changing its morphology from fibrous to lamellar structures. It was observed that both primary Si and eutectic Si were modified when both P and Bi were added to the alloys. For effective refinement, the size of primary Si can be reduced by 50.6% and, the P content should not be less than 0.1 wt% with a Bi content of 0.5–1.0 wt%. Furthermore, an intermetallic phase size reduction also occurs. P addition results in a significant (5.85%) increase in hardness. Adding Bi (up to 1.0 wt%) together with P (up to 0.1 wt%) did not reduce the effect of P on the hardness of the modified alloys. The most effective reduction in roughness achieved during cutting at both low and high speeds was 26.5% and 57.7%, respectively, from modifying the B390 alloy using 0.1 wt%P with 1.0 wt%Bi.

1 January 2018 in Materials Today: Proceedings
Verified
Journal Article
Closed access
PSPhuriphut Saenpong
Phuriphut Saenpong
STsukangkana talangkun
sukangkana talangkun
TLTeerawat Laonapakul
Teerawat Laonapakul
ABApichart Boonma
Apichart Boonma

1 January 2025 in Materials Research Express
Verified
Journal Article
Open access
CPCharinrat Potisawang
Charinrat Potisawang
STsukangkana talangkun
sukangkana talangkun
KPKowit Ponhan
Kowit Ponhan
This research focuses on the fabrication of Al7075 composites reinforced with varying amounts of nano-sized SiC particles (1.0, 1.5, and 2.0 wt%) combined with 0.5 wt% graphite (Gr), employing a hybrid process of mechanical alloying and semi-solid stir casting. The study investigates the influence of SiC content, nanoparticle feeding method, and the role of Gr on the microstructures, mechanical characteristics, and machinability of the composites. Microstructural analysis revealed that integrating milled powders into the molten Al7075 alloy produced a uniform dispersion of nanoscale SiC particles within the α-Al matrix, avoiding the particle agglomeration observed with the conventional method. Higher SiC content resulted in finer grains and improved mechanical performance. The Al7075-0.5Gr-2.0SiC composite exhibited a 16% increase in hardness relative to the unreinforced Al7075 alloy. The inclusion of nanoscale SiC particles notably enhanced tensile strength, while the presence of Gr acted as a lubricant, improving surface roughness.

13 February 2020 in Metals
Verified
Journal Article
Open access
PDF file
STsukangkana talangkun
sukangkana talangkun
CPCharinrat Potisawang
Charinrat Potisawang
PSPhuriphut Saenpong
Phuriphut Saenpong
This research investigated the rheo-die-casting process and the production of an A356/silicon carbide (SiC) composite by a thixoforming. The composite contained 15 percent by weight SiC particles of around 15–37 µm in size as the reinforcing phase. The composite feedstock was produced by semi-solid stir-casting, where pretreated SiC powder was gradually added into the A356 alloy melt to form a continuously stirred slurry composite melt, which was then cast in a steel mold. For thixoforming, the feedstock was reheated to 583 °C (approximately 0.4 fraction liquid), and its viscosity was reduced with shear rate, implying that A356/SiC exhibits shear thinning or non-Newtonian behavior. This is caused by the characteristic billet structure obtained having relatively globular grains that accommodate the flow of the semisolid composite. In the rheo-die-casting process, the A356/SiC feedstock was re-melted at 610–615 °C (approximately 0.8–0.9 fraction liquid) prior to die-casting and the resulting slurry was injected into a die with injection speeds of 3 and 4 m/s and pressures of 11 and 12 MPa, respectively. Two work-pieces of 16 × 15.6 × 205 mm3 were produced in one shot, and the resulting samples were subjected to T6 solution treatment at 540 °C for 1 h, quenched, and aged at 135 °C for 12 h. The results show that both low speed and low pressure rheo-die-cast samples exhibit uneven filling at the end of the part, whilst both high pressure and high speed promote more uniform distribution of SiC particles throughout the part length. In the as-rheo-die-cast condition, the most uniform of microstructures and hardness obtained from a sample fabricated at 4 m/s speed and 12 MPa pressure.

14 August 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
ABApichart Boonma
Apichart Boonma
KSKanchana Sethanan
Kanchana Sethanan
STsukangkana talangkun
sukangkana talangkun
TLTeerawat Laonapakul
Teerawat Laonapakul
This study aims to investigate patient waiting time in General Practice Clinic and identify the main cause of the problem through patient satisfaction survey. 9,232 Patients were randomly observed and quantitative data such as arrival time and waiting time were recorded. Other 1,200 patients were randomly selected for satisfaction survey which is considered as qualitative data. The result indicated that average waiting time of patients was 175.87 minutes with standard deviation of 68.66 minutes. Waiting time at GP clinic appeared to be the longest with an average of 92.9 minutes and standard deviation of 43.4 minutes. Also, based on the obtained data, patients remained positive until their waiting time exceeded 2 hours.